- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Theses and Dissertations /
- Kinesthetic sensitivity to amplitude of active movement...
Open Collections
UBC Theses and Dissertations
UBC Theses and Dissertations
Kinesthetic sensitivity to amplitude of active movement of the shoulder joint Shields, Kenneth William Daniel
Abstract
The purpose of this study was to examine the sensitivity of the kinesthetic system in active movement of the shoulder joint. Three movement amplitudes, 45°, 90° and 125° were studied under two classical psychophysical methods, the method of constant stimuli and the method of average error. Ten subjects were each given one hundred trials per standard for both methods. Results yielded difference limens ranging from 1.4° to 2.2° and constant errors ranging from -0.07° to 1.05°, for the three standards. However, no significant differences occurred among DLs within each method and thus Weber's Ratio was found not to be constant over the range of movement. In terms of constant errors there was only one significant difference among these errors within the two methods. Learning was found not to occur in the method of average error in that algebraic error, absolute error and within subject variability did not exhibit any tendency to become smaller.
Item Metadata
Title |
Kinesthetic sensitivity to amplitude of active movement of the shoulder joint
|
Creator | |
Publisher |
University of British Columbia
|
Date Issued |
1970
|
Description |
The purpose of this study was to examine the sensitivity of the kinesthetic system in active movement of the shoulder joint. Three movement amplitudes, 45°, 90° and 125° were studied under two classical psychophysical methods, the method of constant stimuli and the method of average error. Ten subjects were each given one hundred trials per standard for both methods.
Results yielded difference limens ranging from 1.4° to 2.2° and constant errors ranging from -0.07° to 1.05°, for the three standards. However, no significant differences occurred among DLs within each method and thus Weber's Ratio was found not to be constant over the range of movement. In terms of constant errors there was only one significant difference among these errors within the two methods. Learning was found not to occur in the method of average error in that algebraic error, absolute error and within subject variability did not exhibit any tendency to become smaller.
|
Genre | |
Type | |
Language |
eng
|
Date Available |
2011-05-10
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
|
DOI |
10.14288/1.0077320
|
URI | |
Degree | |
Program | |
Affiliation | |
Degree Grantor |
University of British Columbia
|
Campus | |
Scholarly Level |
Graduate
|
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.