Abstract
This thesis presents results of various investigations which led to the development and validation of a new system for multi-channel surface electromyographic (EMG) recording for clinical examinations (McSERCE) and of a new method for multi-channel surface EMG decomposition (McSED). To obtain individual motor unit action potentials (MUAP5) non-invasively, we invented 1) a brush-tip pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2) a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into the device for sampling the MUAPs distributed on the skin; and 3) a surface EMG recording method which makes use of the bipolar electrode configuration for spatial filtering and the Hilbert transform for correcting for the phase-frequency non-linearity of the bipolar electrode transfer function. Based on these novel electrodes and recording method, the McSERCE system can be used to obtain MUAPs with high selectivity, resolution and signal-to-noise ratios. To extract individual MUAPs from EMG signals recorded on the skin with the McSERCE system, McSED, an effective, efficient, and robust multi-channel surface EMG decomposition method, was developed. The McSED method incorporates the following new techniques: 1) the detection of MUAPs using a multi-pass scheme which locates and matches action potentials detected simultaneously at slightly different locations on the skin; 2) the representation of MUAPs with their spatial distribution and temporal propagation patterns and times of occurrences; 3) the measurement of dissimilarity between MUAPs in terms of these patterns and times of occurrences; 4) the classification of MUAPs using both the “chaining” and the “dissection” characteristics of the single and complete linkage clustering methods, respectively; and 5) the estimation of the firing parameters of an incomplete MUAP train using a maximum-likelihood estimator. Using McSERCE and McSED, a clinical study was conducted on the MU conduction velocities of the abductor pollicis brevis muscle. Results showed that 2% of the 894 MUs detected in the muscles of 32 control subjects were “slow MUs” (v < 2.5 m/sec), whereas 27.7% of the 141 MUs detected in the muscles of four patients with myopathic disorders were slow MUs.
Item Metadata
Title |
Automated decomposition of electromyographic signals recorded with surface electrode arrays
|
Creator | |
Publisher |
University of British Columbia
|
Date Issued |
1994
|
Description |
This thesis presents results of various investigations which led to the development and validation of a
new system for multi-channel surface electromyographic (EMG) recording for clinical examinations
(McSERCE) and of a new method for multi-channel surface EMG decomposition (McSED).
To obtain individual motor unit action potentials (MUAP5) non-invasively, we invented 1) a brush-tip
pin (BTP) electrode made of a bundle of fine wires for contacting the skin without electrolytic jelly; 2)
a miniature active surface electrode array consisting of the BTP electrodes and signal buffers built into
the device for sampling the MUAPs distributed on the skin; and 3) a surface EMG recording method
which makes use of the bipolar electrode configuration for spatial filtering and the Hilbert transform for
correcting for the phase-frequency non-linearity of the bipolar electrode transfer function. Based on
these novel electrodes and recording method, the McSERCE system can be used to obtain MUAPs with
high selectivity, resolution and signal-to-noise ratios.
To extract individual MUAPs from EMG signals recorded on the skin with the McSERCE system,
McSED, an effective, efficient, and robust multi-channel surface EMG decomposition method, was
developed. The McSED method incorporates the following new techniques: 1) the detection of MUAPs
using a multi-pass scheme which locates and matches action potentials detected simultaneously at slightly
different locations on the skin; 2) the representation of MUAPs with their spatial distribution and
temporal propagation patterns and times of occurrences; 3) the measurement of dissimilarity between
MUAPs in terms of these patterns and times of occurrences; 4) the classification of MUAPs using both
the “chaining” and the “dissection” characteristics of the single and complete linkage clustering methods, respectively; and 5) the estimation of the firing parameters of an incomplete MUAP train using a
maximum-likelihood estimator.
Using McSERCE and McSED, a clinical study was conducted on the MU conduction velocities of the
abductor pollicis brevis muscle. Results showed that 2% of the 894 MUs detected in the muscles of 32
control subjects were “slow MUs” (v < 2.5 m/sec), whereas 27.7% of the 141 MUs detected in the
muscles of four patients with myopathic disorders were slow MUs.
|
Extent |
4506804 bytes
|
Genre | |
Type | |
File Format |
application/pdf
|
Language |
eng
|
Date Available |
2009-04-09
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
|
DOI |
10.14288/1.0065217
|
URI | |
Degree | |
Program | |
Affiliation | |
Degree Grantor |
University of British Columbia
|
Graduation Date |
1994-11
|
Campus | |
Scholarly Level |
Graduate
|
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.