- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Theses and Dissertations /
- Weakly supervised landmark detection for automatic...
Open Collections
UBC Theses and Dissertations
UBC Theses and Dissertations
Weakly supervised landmark detection for automatic measurement of left ventricular diameter in videos of PLAX from cardiac ultrasound Sahebzamani, Ghazal
Abstract
The length of the left ventricle and how it changes throughout a cardiac cycle is an indicative of the health of the heart in clinical studies. Currently, this measurement is computed through manual labeling made by experienced sonographers. This labeling procedure is highly costly, time-consuming, and prone to inter-observer and intra-observer errors. In order to overcome these challenges, this thesis proposes a deep neural network-based model to automate the detection of landmarks corresponding to the diameter of the heart. The dataset used for this work is sparse in the temporal dimension, having annotations merely available on end-diastolic and end-systolic frames, and the final goal of the model is to provide meaningful measurements across the entire cardiac cycle. The proposed network leads to 10.08% average ejection fraction error, and 12.18% mean percentile error, which is satisfactory based on the requirements of this project.
Item Metadata
Title |
Weakly supervised landmark detection for automatic measurement of left ventricular diameter in videos of PLAX from cardiac ultrasound
|
Creator | |
Publisher |
University of British Columbia
|
Date Issued |
2021
|
Description |
The length of the left ventricle and how it changes throughout a cardiac cycle is an indicative of the health of the heart in clinical studies. Currently, this measurement is computed through manual labeling made by experienced sonographers. This labeling procedure is highly costly, time-consuming, and prone to inter-observer and intra-observer errors. In order to overcome these challenges, this thesis proposes a deep neural network-based model to automate the detection of landmarks corresponding to the diameter of the heart. The dataset used for this work is sparse in the temporal dimension, having annotations merely available on end-diastolic and end-systolic frames, and the final goal of the model is to provide meaningful measurements across the entire cardiac cycle. The proposed network leads to 10.08% average ejection fraction error, and 12.18% mean percentile error, which is satisfactory based on the requirements of this project.
|
Genre | |
Type | |
Language |
eng
|
Date Available |
2021-03-23
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
Attribution-NonCommercial-NoDerivatives 4.0 International
|
DOI |
10.14288/1.0396334
|
URI | |
Degree | |
Program | |
Affiliation | |
Degree Grantor |
University of British Columbia
|
Graduation Date |
2021-05
|
Campus | |
Scholarly Level |
Graduate
|
Rights URI | |
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International