- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Faculty Research and Publications /
- Single-image wavefront curvature sensing.
Open Collections
UBC Faculty Research and Publications
Single-image wavefront curvature sensing. Hickson, Paul; Burley, Gregory S.
Abstract
A single defocused star image contains sufficient information to uniquely determine the spatial phase fluctuations
of the incident wavefront. A sensor which responds to the intensity distribution in the image produces signals
proportional to the wavefront curvature within the pupil and the radial slope at the pupil boundary. Unlike Roddier's
differential curvature sensing technique, a single-image sensor does not cancel intensity fluctuations due to atmospheric
scintillation. However, it has been shown that at typical astronomical sites the scintillation signal is negligibly small.
A single-image curvature sensor can theoretically achieve a signal-to-noise ratio of order Q approximately equals r20/(lambda) z0
where r0 is Fried's correlation length, (lambda) is the wavelength, and z0 is the root-mean-square distance through
the atmosphere, weighted by the refractive index structure constant C2n. This is more than adequate for AO systems
whenever D/r0
Item Metadata
| Title |
Single-image wavefront curvature sensing.
|
| Creator | |
| Publisher |
Society of Photo-Optical Instrumentation Engineers (SPIE)
|
| Date Issued |
1994
|
| Description |
A single defocused star image contains sufficient information to uniquely determine the spatial phase fluctuations
of the incident wavefront. A sensor which responds to the intensity distribution in the image produces signals
proportional to the wavefront curvature within the pupil and the radial slope at the pupil boundary. Unlike Roddier's
differential curvature sensing technique, a single-image sensor does not cancel intensity fluctuations due to atmospheric
scintillation. However, it has been shown that at typical astronomical sites the scintillation signal is negligibly small.
A single-image curvature sensor can theoretically achieve a signal-to-noise ratio of order Q approximately equals r20/(lambda) z0
where r0 is Fried's correlation length, (lambda) is the wavelength, and z0 is the root-mean-square distance through
the atmosphere, weighted by the refractive index structure constant C2n. This is more than adequate for AO systems
whenever D/r0
|
| Genre | |
| Type | |
| Language |
eng
|
| Date Available |
2011-09-20
|
| Provider |
Vancouver : University of British Columbia Library
|
| Rights |
Attribution-NonCommercial-NoDerivatives 4.0 International
|
| DOI |
10.14288/1.0107621
|
| URI | |
| Affiliation | |
| Citation |
Hickson, Paul; Burley, Gregory S. Single-image wavefront curvature sensing. Adaptive Optics in Astronomy, edited by Mark A. Ealey, Fritz Merkle. Proceedings of SPIE Volume 2201, 549, 1994.
|
| Publisher DOI |
10.1117/12.176090
|
| Peer Review Status |
Reviewed
|
| Scholarly Level |
Faculty
|
| Copyright Holder |
Hickson, Paul
|
| Rights URI | |
| Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International