Pitfalls in the determination of human acylated ghrelin plasma concentrations using a double antibody enzyme immunometric assay Trivedi, Arjun; Babic, Sandra; Chanoine, Jean-Pierre
Abstract
Objectives: To investigate the effect of hemolysis and protease inhibitors on acylated ghrelin (AG) concentrations measured with a double antibody enzyme immunometric assay that uses an acetylcholinesterase (AChE)-Fab’ conjugate. Design and Methods: Samples were hemolysed or treated with PHMB (phydroxymercuribenzoate), PMSF (phenylmethanesulfonylfluoride) or AEBSF (4-(2-Aminoethyl) benzenesulfonyl fluoride) to prevent AG degradation. Results: Hemolysis decreased AG concentrations. PHMB or PMSF did not affect the assay. The standard curve was abolished by AEBSF but rescued by addition of a washing step prior to the AChE-Fab' conjugate. Conclusions: Hemolysis and AEBSF may affect AG determination.
Item Metadata
Title |
Pitfalls in the determination of human acylated ghrelin plasma concentrations using a double antibody enzyme immunometric assay
|
Creator | |
Contributor | |
Date Issued |
2012-01
|
Description |
Objectives: To investigate the effect of hemolysis and protease inhibitors on acylated ghrelin
(AG) concentrations measured with a double antibody enzyme immunometric assay that uses an
acetylcholinesterase (AChE)-Fab’ conjugate.
Design and Methods: Samples were hemolysed or treated with PHMB (phydroxymercuribenzoate),
PMSF (phenylmethanesulfonylfluoride) or AEBSF (4-(2-Aminoethyl)
benzenesulfonyl fluoride) to prevent AG degradation.
Results: Hemolysis decreased AG concentrations. PHMB or PMSF did not affect the assay. The
standard curve was abolished by AEBSF but rescued by addition of a washing step prior to the
AChE-Fab' conjugate.
Conclusions: Hemolysis and AEBSF may affect AG determination.
|
Subject | |
Genre | |
Type | |
Language |
eng
|
Date Available |
2015-10-24
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
Attribution-NonCommercial-NoDerivs 2.5 Canada
|
DOI |
10.14288/1.0103472
|
URI | |
Affiliation | |
Citation |
Trivedi, A., Babic, S., & Chanoine, J. (2012). Pitfalls in the determination of human acylated ghrelin plasma concentrations using a double antibody enzyme immunometric assay. Clinical Biochemistry, 45(1–2), 178-180.
|
Publisher DOI |
10.1016/j.clinbiochem.2011.10.023.
|
Peer Review Status |
Reviewed
|
Scholarly Level |
Faculty
|
Copyright Holder |
Elsevier
|
Rights URI | |
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
Attribution-NonCommercial-NoDerivs 2.5 Canada