@prefix vivo: . @prefix edm: . @prefix ns0: . @prefix dcterms: . @prefix skos: . vivo:departmentOrSchool "Science, Faculty of"@en, "Physics and Astronomy, Department of"@en ; edm:dataProvider "DSpace"@en ; ns0:degreeCampus "UBCV"@en ; dcterms:creator "Mottershead, Jeffrey Daniel Frederick"@en ; dcterms:issued "2009-12-10T23:26:31Z"@en, "2005"@en ; vivo:relatedDegree "Master of Science - MSc"@en ; ns0:degreeGrantor "University of British Columbia"@en ; dcterms:description """Recent angle-resolved photoemission spectroscopy (ARPES) results on the high-temperature superconductor (HTSC) Tl₂Ba₂CuO₄+[sub Δ] (T12201) are presented. A very overdoped sample with a T[sub c] of 30 K was found to have a Fermi surface consisting of a large hole pocket centered at (Π,Π), which is approaching a topological transition. A superconducting gap consistent with a d[sub x[sup 2]-y[sup 2]] order parameter was detected. In contrast with the underdoped HTSCs, where the quasiparticle (QP) linewidth at the top of the band is maximal in the antinodal direction and minimal in the nodal direction, overdoped T12201 was revealed to have a reverse nodal/antinodal anisotropy, with sharp QP peaks in the antinodal region and broader peaks in the antinodal region. The T12201 results establish T12201 as a valuable material for exploring the overdoped side of the phase diagram with ARPES. They also raise numerous questions that demand further ARPES measurements over a broader range of dopings, as well as temperature-dependent measurements. In parallel with the T12201 research, a new in-house ARPES system is being constructed at University of British Columbia (UBC). The ARPES system under construction at UBC incorporates a molecular beam epitaxy (MBE) system for the growth of a much broader range of materials than can typically be studied by ARPES. Novel design techniques to improve the accuracy of ARPES measurements are presented."""@en ; edm:aggregatedCHO "https://circle.library.ubc.ca/rest/handle/2429/16342?expand=metadata"@en ; skos:note "An Angle-Resolved Photoemission Spectroscopy Study of T l 2 B a 2 C u 0 6 + ( 5 Analysis of recent results and the construction of a new system by Jeffrey Daniel Frederick Mottershead B.Sc, The University of Alberta, 2001 A THESIS SUBMITTED IN PARTIAL F U L F I L M E N T O F T H E REQUIREMENTS FOR T H E D E G R E E OF M A S T E R OF SCIENCE in The Faculty of Graduate Studies (Physics) T H E UNIVERSITY OF BRITISH COLUMBIA April 22, 2005 © Jeffrey Daniel Frederick Mottershead, 2005 11 Abstract Recent angle-resolved photoemission spectroscopy (ARPES) results on the high-temperature superconductor (HTSC) TbBa^CuC^+s (T12201) are presented. A very overdoped sample with a Tc of 30 K was found to have a Fermi surface consisting of a large hole pocket centered at (TT, 7r), which is approaching a topological transition. A superconducting gap consistent with a dxi-y2 order parameter was detected. In contrast with the underdoped HTSCs, where the quasiparticle (QP) linewidth at the top of the band is maximal in the antinodal direction and minimal in the nodal direction, overdoped T12201 was revealed to have a reverse nodal/antinodal anisotropy, with sharp QP peaks in the antinodal region and broader peaks in the antinodal region. The T12201 results establish T12201 as a valuable material for exploring the overdoped side of the phase diagram with ARPES. They also raise numerous questions that demand further ARPES measurements over a broader range of dopings, as well as temperature-dependent measurements. In parallel with the T12201 research, a new in-house ARPES system is being constructed at University of British Columbia (UBC). The ARPES system under construction at UBC incorporates a molecular beam epitaxy (MBE) system for the growth of a much broader range of materials than can typically be studied by ARPES. Novel design techniques to improve the accuracy of ARPES measurements are presented. Contents A b s t r a c t ii C o n t e n t s iii L i s t of F i g u r e s v A c k n o w l e d g e m e n t s vi 1 I n t r o d u c t i o n 1 1.1 Correlated systems 2 1.2 The cuprates 2 1.3 Angle-resolved photoemission spectroscopy 3 1.4 Tl 2 Ba 2 Cu06+5 as a material for ARPES studies 4 1.5 Construction of an in-house ARPES system 5 2 A R P E S o n T l 2 B a 2 C u 0 6 + ( s 6 2.1 Data analysis on T12201-OD30 9 2.2 Momentum evolution of quasi-particle lineshapes 20 2.2.1 Significance of QP peak anisotropy 22 2.3 Conclusion 26 3 C o n s t r u c t i o n of a new A R P E S sys t em 28 3.1 Elements of the new ARPES system 29 3.2 Electron analyzer 29 3.2.1 Analyzer resolution 31 3.3 Cryostat and manipulator 33 3.3.1 Cryostat materials 36 3.3.2 6 angle manipulation 38 3.3.3 z translation 39 3.3.4 4> rotation 39 Contents i v 3.3.5 x-y translation 39 3.3.6 Sample mounting and w rotation 39 3.3.7 Temperature control 40 3.4 Helium lamp and monochromator 40 3.5 Conclusion 41 Bibliography 42 List of Figures 2.1 Magnetization curves of T12201 10 2.2 X-ray rocking curve of T12201 10 2.3 ARPES data and LDA calculations for T12201-OD30 11 2.4 Second derivative of ARPES spectra on T12201-OD30 12 2.5 Change in the spectral function as a result of a superconducting gap 14 2.6 Location data sets taken in momentum space 15 2.7 AMRO FS for T12201 17 2.8 Tight-binding fits and symmetrization of ARPES spectra on T12201-OD30 18 2.9 Effects of experimental parameters on the L E M of ARPES spectra 21 2.10 Change in ARPES lineshapes as a function of momentum . . . . 23 2.11 Anisotropy between nodal and antinodal QP peaks in T12201-OD63 and T12201-OD30 24 3.1 The UBC ARPES system 30 3.2 Analyzer angular resolution test apparatus 32 3.3 Cryostat 35 vi Acknowledgements I am extremely grateful to my supervisor, Dr. Andrea Damascelli, for focusing my efforts in the right directions, regardless of the level of resistance I offered, and for valuable lessons on my psychology [1, 2]. Thanks also to Dr. Nik Ingle, who taught me how to do ARPES in the first place. I am also grateful to Dr. Ruixing Liang and Darren Peets, who grew the Tl2Ba2Cu04+, the work function, from its energy, giving the electron a final energy of e + hw — 4>. While leaving the material, the momentum parallel to the surface of the sample is conserved, but perpendicular to the sample, there is lack of symmetry, and the momentum perpendicular to the plane is not conserved. The fact that the momentum is not conserved in the perpendicular direction is not a problem in the analysis of 2D electrons, however, where there is no electronic dispersion perpendicular to the surface of the sample. By measuring the photoelectron energy, and the angle of emission, from which the parallel component of momentum is readily Chapter 1. Introduction 4 calculable, the electronic dispersion of a 2D material can be readily determined. The electronic structure of the CuC>2 band, thought to be responsible for su-perconductivity in the cuprates, is sufficiently close to 2D that they are often treated as 2D. As well as having a quasi-2D electronic structure, the cuprates further lend themselves to ARPES studies as they naturally cleave parallel to the copper-oxide planes. Thus, ARPES data yield direct information about the single-particle spectral function for occupied states, and hence is a valuable and unique tool for determining the electronic origins of the exotic properties found in the cuprates. Note that the simple model described above does not take into account scattering or surface effects. For a more complete model of the photoe-mission process, see Hufner [7], and for a review of ARPES on the cuprates, see Damascelli et al. [8]. 1.4 T l 2 Ba 2 Cu0 6 + ( 5 as a material for ARPES studies Certain families of cuprates, particularly Bi2Sr2Cu06+,5 (Bi2201), its bilayer cousin Bi2Sr2CaCu208+5 (Bi2212) and L a 2 _ x S r x C u 0 4 (LSCO) have been ex-tensively studied by ARPES. While these studies have produced many valuable results [8], they have been complicated by material issues. Bi2201 and Bi2212, for instance, cleave very readily, making it easy to get a vacuum-clean surface on which to do photoemission work. Bi2201 and Bi2212 are therefore standard materials for ARPES studies, but from a theoretical modelling perspective, they are not at all ideal. Further, when studying Bi-based cuprates, one is faced with the choice of studying either the single-layer compound Bi2201, which has a low Tc, or Bi2212, which has a much higher Tc, but also has the problem of being a bilayer compound, where there is inter-layer coupling between neighboring copper-oxygen planes, complicating both analysis of the ARPES spectra and the theoretical modelling of the compound. Furthermore, Bi2201 and B12212 are not well suited to bulk sensitive measurements, complicating the comparison of cuprate data from complimentary techniques. The thallium compound Tl2Ba2Cu06+ 1 Ato (degrees) Figure 2.2: (0 0 10) X-ray rocking curve for a typical crystal (Tc = 67.7 K): the F W H M is 0.034°. (Reproduced from Peets et al. [18]) Chapter 2. ARPES on TkBaaCuOa+t 11 VFS=50%! V F S=63%«'| I I \\ (a) (7t,7t) T12201-OD30 T=10K hv=59eV jjjj ^^^^^^^^^^^^^^^^^ •11111 -200 0 -200 0 Binding Energy (meV) Figure 2.3: L D A Fermi surface for two different doping levels corresponding to a volume of 50% (cyan, dashed) and 60% (blue, solid) of the Brillouin zone. (b,c) A R P E S spectra taken at T = 10 K on T12201-OD30 along the directions marked by the arrows in (a), (d) A R P E S F S of T12201-OD30 along with a tight-binding fit of the data (black lines). Chapter 2. ARPES on Tl2BaaCuO&+6 12 9 Momentum Figure 2.4: Second derivative of the APRES spectra in Figure 2.3b with respect tide (QP) peak shows a strong dispersion, which is clearly evident to 150 meV below the Fermi energy (EF)- This dispersion can be seen more clearly by plot-ting the second derivative of the ARPES spectra with respect to the binding energy. Figure 2.4 shows a result of this analysis for the spectra in Figure 2.3b, showing that the QP peak can be followed to ~ 250 meV binding energy, where the band bottom can be seen. In Figure 2.3c, the band is much shallower, with the van Hove singularity located at ~ 39 meV below EF-The ARPES FS is obtained by first normalizing the ARPES spectra at high binding energies and then integrating the ARPES spectra over a ± 5 meV window about Ep. This procedure was done over the entire data set, which covers more than one quadrant in two different BZs. The results are then downfolded to the reduced zone scheme. This procedure was used in Damascelli et al. [20] and serves a number of purposes. This procedure serves as a criterion for determining the alignment of the sample. Only if the alignment of the sample is correctly determined will points on the FS from the two different zones be mapped directly on top of each other. The signal-to-noise ratio is also enhanced to binding energy. Chapter 2. ARPES on TJ 2 Ba2Cu0 6 + ( 5 13 by using this technique, as, for each point on the reduced zone, at least two sets contribute to it. Next, the FS is symmetrized with respect to the zone diagonal, (0,0) — (7T, 7r), averaging over all identical symmetry points. This serves to further increase the signal-to-noise ratio, and to remove any artifacts pertaining to the anisotropy in angular resolution due to the experimental geometry [20]. Note, however, that the resolution anisotropy problems are inherently less severe for our measurement geometry of rotating approximately about (7r, TT) than for the conventional motion about T (see Figure 2.6). It should be noted that at T = 10 K, a d-wave superconducting gap is open along the FS. As a result, the procedure described above returns the loci of the minimum gap. Note, though, that these points do correspond to the underlying normal-state FS crossings, as can be seen in Figure 2.5. Calculations of the Bardeen-Cooper-Schrieffer (BCS) spectral function above and below Tc give this result exactly. For the HTSCs, there is no accepted theoretical result, but it is not unreasonable to expect that some aspects of BCS theory will apply to the overdoped side of the phase diagram, where the cuprates are believed to exhibit more conventional behaviour. In fact, the gap structure shown in Figure 2.5 agrees qualitatively with BCS theory, with the minimum gap being at the same location as the Fermi-crossing in the normal state. The FS found for T12201-OD30 is a hole-pocket centered about (ir,ir). As can be seen by the low binding energy (~39 meV) of the van Hove singularity in the antinodal direction (see Figure 2.3), the FS appears to be approaching a topological transition from hole-like to electron-like. The volume of the FS is 63 ± 2% of the BZ, which corresponds to a carrier concentration of 1.26 ± 0.04 holes/Cu atom. This agrees very well with Hall-coefficient [22] and A M R O [15, 23] experiments, which found FS volumes of 1.3 holes/Cu atom on a sample with a Tc of 15 K, and 1.24 holes/Cu atom on a sample with a Tc of 20 K, respectively. All of these measurements indicate that the low-energy electronic structure of highly overdoped T12201 is dominated by a single CuO band. In the LDA calculations of Figure 2.3a (cyan, dashed), for undoped T12201, we see a small electron pocket coming from the TIO band. Neither ARPES nor A M R O measurements show any evidence for such an electron pocket. This result should be expected, as the samples under study are sufficiently doped that if the chemical potential in the LDA calculations is adjusted in a rigid-band fashion, the TIO band is emptied. Even in the absence of excess oxygen (6 = 0), the holes introduced by the residual non-stoichiometry ( C u 2 + substituted for S r 3 + ) are responsible for ~0.14 hole per formula unit, which is sufficient to empty Chapter 2. ARPES on Tl2Ba2Cu06+s 14 Figure 2.5: (Left) Change in the B C S spectral function across Tc, showing the opening of the gap, the backward dispersion of the Bogoliubov QPs , and their intensity decrease upon approaching kF due to the pres-ence of coherence factors I**, vk- (Right) A R P E S results from Bi2223 showing good qualitative agreement. (Reproduced from Matsui et al. [21]) Chapter 2. ARPES on ThBa^CuOg+s 15 in,n) ( Figure 2.6: Direction of the cuts in momentum space on which ARPES data were obtained for T12201-OD30 (red). Momentum space is rep-resented in the repeated zone scheme, with the tight-binding FS included for reference (blue). Data is seen to cover two irreducible symmetry units, and multiple BZs. Chapter 2. ARPES on TI2Ba2Cu06+,$ 16 the TIO band. In fact, the non-stoichiometry of T12201 may push the 6 = 0 system sufficiently far from half-filling to explain why it is not a charge transfer insulator like undoped LSCO [23]. The ARPES (Figure 2.3d) and AMRO (Figure 2.7) Fermi surfaces are in good agreement with each other, but they are notably rounder than in the LDA calculations (Figure 2.3a). The LDA calculations could be improved by including correlation effects and the effects of doping beyond a rigid-band ap-proximation. The ARPES data can alternatively be modelled by fitting the parameters in the tight-binding dispersion [13] ek = I* + ^(cos + c o s by) + *2 cos kx cos ky + ^(cos 2kx + cos 2ky)+ + y (cos2fcx cos fcy + cos kx cos2ky) + ts cos2&x cos2fcy. The results of the fit are shown in Figure 2.3d (black lines). The fit not only reproduces the FS, but it also matches the QP energy well at (0,0), and very well at (7r,0) (see Figures 2.8f, g). Values for the fit parameters are as follows: H = 0.2438, ti = -0.725, t2 = 0.302, t3 = 0.0159, U = -0.0805, t5 = 0.0034. Figure 2.8 shows the analysis of ARPES spectra taken in the antinodal region on T12201-OD30, demonstrating a superconducting gap consistent with a dxi_yi form (i.e., cosfcx — cos/cy). It is a standard technique to follow the opening of the superconducting gap via a shift in the leading edge midpoint (LEM) as a function of temperature [8]. Unfortunately, it was found that all angle-dependent information in the ARPES spectra was lost if the cyrostat temperature got significantly above 10 K. It is not clear whether this is a result of something extrinsic, like outgassing of the cyrostat, or an intrinsic problem with surface reconstruction of overdoped T12201 above 10 K. Regardless of its origin, this effect rendered it impossible for a temperature-dependent study to be done. Nevertheless, a superconducting gap consistent with a ci-wave order parameter can be clearly seen in the symmetrization of the nodal and antinodal spectra [24, 25]. While this procedure does not return a quantitative value for the size of the superconducting gap, it provides a qualitative criterion for determining whether or not there is a Fermi crossing, and hence whether or not a superconducting gap has opened. In the symmetrized spectra, the presence of a peak in the spectra at Ep indicates a crossing. This crossing is clearly seen in the nodal direction (Figure 2.8a), but not in the antinodal direction (Figure Chapter 2. ARPES on Tl2BaaCu06+s 17 Figure 2.7: Projection of the AMRO FS onto the a-b plane for T12201. The magnitude of the c-axis warping has increased fourfold to empha-size the eight loci where k z dispersion vanishes. (Reproduced from Hussey et al. [15]) Chapter 2. ARPES on ThBa^CuOe+s 18 Figure 2.8: (a,b) Symmetrization of the A R P E S spectra from along cut I and II shown in Figure 2.3. (c) Enlarged view of the FS of T12201-OD30 near (7r,0). (d) Selected spectra from along cut II in (c); their k-space positions are indicated by circles of corresponding colour. (e,f) Q P linewidth T and peak position from a Lorentzian fit of the energy distribution curves along cut II in (c). (g) Q P peak position along cut III in (c). Black lines in (c,f,g) are the tight-binding results. Chapter 2. ARPES on TkBa^CuOe+s 19 2.8b), which establishes the existence of the kp. This function was then multiplied by the Fermi function and convoluted with the instrumental energy resolution function to obtain the functional form that was fit to the data [8]. This procedure for determining the gap has been done for Bi2212 [26]. Figure 2.8d (inset) shows good agreement between the raw data and the fit. Since heavily overdoped cuprates have weaker electron correlations, the good agreement between the measured QP peak and the Lorentzian is not surprising. Figures 2.8g and f show the peak positions from the fits compared with the tight-binding normal state dispersion, near the antinodal region. At higher binding energies, there is good agreement between the fit peak positions and the normal state dispersion. At lower binding energies, however, the QP peak does not reach EF and instead reaches a minimum at A p ~ 17 meV and disperses back to higher binding energy. This behaviour is a standard feature of Bogoliubov QPs. At the nodal region, the QP peak does cross Ep (not shown), while at intermediate momenta, a gap smaller than the one at the nodal region is observed. The ARPES gap size is often determined by analyzing the L E M [8]. This procedure, however, is not robust at finite temperatures and finite instrument resolutions. The L E M is shown to vary rapidly and nonlinearly with both temperature and resolution. This effect has caused confusion, as the Fermi-Dirac distribution function for a metal is always equal to 1/2 at EF, making the L E M of the angle-integrated photoemission spectrum exactly at Ep • Even for a metal, with ARPES spectra, the LEMs at different fc-values will vary widely with temperature and instrument resolutions [27]. Further, the nature of these variations will be highly dependent on the details of the electronic dispersion and spectral lineshapes. An important consequence is that at kp, the L E M is often well above Ep. Analysis on the change of the L E M as a function of temperature, lineshape, electronic dispersion, error in determining kp and instrument resolution in Bi2212 has been performed and shows that the discrepancy between the L E M and the QP peak position is on the same order as the superconducting gap itself for typical experimental parameters, in the highly overdoped side of the phase diagram [27]. Results showing the evolution of the L E M with respect to experimental parameters is shown in Figure 2.9. Chapter 2. ARPES on TkBa^CuOe+s 20 Despite the L E M gap not being as robust as the gap determined by QP peak position, the L E M gap was still determined for T12201-OD30 (ALE ~ 8 meV), for comparison with L E M simulations. In fact, the difference between the two quantities (Ap ~ \"2ALE) has been noted for other cuprates [8, 27]. 2.2 Momentum evolution of quasi-particle lineshapes The momentum evolution of the QP lineshapes depends on the strength and nature of the many-body effects present in the materials. The shape of ARPES energy distribution curves (EDCs), however, are affected by not only the band structure and correlation effects, but also the momentum and energy resolution of the analyzer, scattering, matrix element effects and the incoherent back-ground. Providing a criterion for separating ARPES spectra into a QP line-shape and an incoherent background is a challenging task [28]. Nevertheless, it is possible to reduce the problems from matrix element effects by choosing appropriate experimental parameters, such that by subtracting a phenomeno-logical ARPES background (determined from spectra at k kp) a sufficient QP peak can be isolated for a qualitative analysis of QP lineshape as a function of momentum. For this experiment, circularly polarized 59 eV photons were used. Circular polarization was chosen in order to minimize matrix element effects, which can be shown to be most extreme for linear polarization based on sym-metry arguments [8]. The photon energy was chosen as a result of experience on other cuprates - specifically, La2 - x S r x C u 0 4 (LSCO) where similar photon energies were used to reveal structure that had previously been unobservable in ARPES data [29]. In order to gain more reliable information, data was taken over multiple BZs, where it was observed that for the same point in the reduced zone scheme, lineshapes from different BZs were qualitatively very similar. Turning our attention to the evolution of the lineshapes as a function of momentum, we see that in the nodal region, as has been previously observed in photoemission studies of the cuprates, the width of the QP peak increases as a function of binding energy (Figure 2.8b), as expected from simple phase-space arguments. This is in sharp contrast to the antinodal region, where the sharpest peak is found at the bottom of the band. The linewidth T of the QP peak is observed to grow from ~30 to ~55 meV as the QP peak disperses from ~39 to ~20 meV binding energy (see Figure 2.8e). Possible origins for this anomalous Chapter 2. ARPES on Tl2Ba2CuOG+d 21 Figure 2.9: Temperature dependence of the model Bi2212 photoemission spec-tra with no gap included, (a-c) Electronic dispersion curves (EDCs) for temperatures ranging from 10 to 290 K with 20 K steps; nar-rowest EDCs corresponding to the lowest temperature, (d) L E M position as a function of temperature for different instrument mo-mentum resolutions, (e) L E M position as a function of temper-ature for different instrument energy resolutions, (f) L E M posi-tion as a function of temperature for different positions in k. The lower curves filled with grey in panels (a) and (c) represent the temperature-dependent background for 10 and 290 K. The bold curves in panels (d)-(f) show the L E M for typical experimental pa-rameters R - UJ = 20 meV, Rk = 0.007 A, k = kp- (Reproduced from Kordyuk et al. [27]) Chapter 2. ARPES on TkBa^CuOe+s 22 behaviour will be discussed later. Another striking feature of the lineshape evolution is that the QP peaks are much broader in the nodal region than in the antinodal region (see Figures 2.8a, b). Figure 2.10a presents a compilation of spectra along the FS contour, with k slightly smaller than kF, corresponding to a binding energy of ~35 meV. This choice is dictated by the need to be sufficiently below Ep to have the spectra affected by neither the opening of the d-wave gap nor the anomalous low-binding-energy broadening depicted in Figure 2.8e. A sharp peak near (n, 0) is seen to become progressively broader as (7r/2,7r/2) is approached. In order to determine whether this apparent broadening represents an increase in the QP linewidth T or merely a loss of spectral weight, the momentum-independent background, taken from k ~S> kF, is subtracted from the ARPES spectra as shown in Figure 2.10b [8, 28]. Figure 2.10c shows the result of integrating the background spectra over varying energy ranges. When the QP peak is integrated over a small range, there is a drop as a function of FS angle; i.e., when integrated over a narrow energy window, the QP appears to lose weight in the nodal region. As the energy window of the integration region is expanded to 550 meV, however, the spectral weight of the QP peaks is seen to remain constant. This indicates that this fc-dependent broadening is entirely due to a broadening of the QP spectrum rather than due to matrix element effects. 2.2.1 S i g n i f i c a n c e o f Q P p e a k a n i s o t r o p y The observed QP anisotropy of T12201-OD30, with peaks much broader in the nodal than the antinodal region, is in sharp contrast with the behaviour observed in underdoped cuprates, where the QP peaks are sharp near (7r/2,7r/2) and very broad around (TT, 0) in the normal state. As doping is increased, the antinodal QP peaks are observed to gain coherence, but they still remain significantly broader than the nodal peaks at optimal doping, creating the expectation that increasing doping will simply render the QP linewidths more isotropic. The QP peaks are seen to gain coherence at all momenta, but especially in the antinodal region, in the superconducting state. Even in the superconducting state, however, ARPES linewidths are still highly anisotropic, with a minimum at (7r/2,7r/2) [8]. The reverse QP anisotropy observed in T12201-OD30 (Figure 2.11b), and a similar, albeit less pronounced, effect in T12201-OD63 (Figure 2.11a) indicate a trend with respect to doping. The notion that this trend may be generic in cuprates is suggested by recent ARPES results from x = 0.22 Chapter 2. ARPES on Tl2Ba2Cu06+6 23 Figure 2.10: (a) T12201-OD30 ARPES spectra at k slightly smaller than kF along the FS contour (corresponding to a peak position of ~35 meV). (b) Selected spectra from (a) along with corresponding & > kF background, (c) Spectral weight of background subtracted spectra integrated over different energy ranges vs. FS-angle a. (d) QP linewidth T vs. a. Chapter 2. ARPES on T J 2 B a 2 C u 0 6 + ( s 24 Binding Energy (meV) Binding Energy (meV) Figure 2.11: (a) T12201-OD63 and (b) T12201-OD30 spectra at k < kF in the nodal and antinodal regions. L S C O [16, 17] showing a reverse Q P anisotropy qualitatively similar to that seen in T12201-OD63. For both x = 0.22 L S C O and T12201-OD63, Tc ~ 2 /3r c m a x . Investigating quantum criticality and phase changes The Q P anisotropy reversal observed could be coincident with the proposed quantum critical point in the cuprate phase diagram [30]. It has been suggested that quantum phase transition from a dxi_y2 to a dx?-yi + idxy order parame-ter, as a function of some tuning parameter, possibly doping, may give rise to increased scattering rates of the nodal QPs. At the phase transition, low-energy bosonic modes would couple to the gapless nodal QPs [31]. While this proposal provides a convenient mechanism for explaining the broad Q P lineshape in the nodal direction, a complex dxy pairing component (i.e., sin/c^sin/Cj,) would gen-erate an order parameter with no nodes. This is inconsistent with the results from T12201-OD30, which show a clear FS crossing in the nodal region. Heat transport measurements on T12201 indicate that the superconducting order pa-rameter has nodes, and further, is consistent with the simplest dx-i-y2 pairing scenario [11]. The T12201-OD30 data, coupled with the heat transport data, provides strong evidence that quantum criticality, if it exists, is either not asso-ciated with the development of an idxy order parameter, or that doping is not, in fact, the actual tuning parameter. Chapter 2. ARPES on Tl2Ba2Cu06+s 25 ARPES-specif ic broadening mechanisms Magnetotransport experiments - where a small magnetoresistance and a weak T-dependence of the resistivity and cotangent of the Hall angle have been ob-served - do not indicate the presence of strongly /c-dependent scattering rates. While these experiments are performed in the normal state, in contrast to the ARPES results presented, it may indicate that ARPES-specific scattering mech-anisms for the nodal QPs, such as elastic forward scattering and the effects of a non-zero kz dispersion, have to be examined. The effect of elastic forward (small-angle) scattering due to out-of-plane impurities, such as cation substitution and interstitial oxygen, on the ARPES spectra has been shown to be suppressed in cuprates in the superconducting state by a cancellation with an anomalous scattering process for states near the FS and away from the nodal direction. This anomalous scattering process van-ishes in the nodal direction [32]. Elastic forward scattering contributes a term Ticp | > \\ A ^ \\ [32]. This behaviour is not unexpected, as below T c , TkF must be suppressed for electron energies smaller than the gap size, to conserve energy. In the nodal direction, however, the forward scattering is still pair-breaking, and no suppression of scattering rates is expected. This reduction in the forward scattering varies smoothly from no reduction in the nodal region to a strong suppression of the effects of forward scattering in the antinodal region, consistent with the observed trend. While forward scattering may explain why a strong reverse anisotropy of low-energy QP widths is seen in seen in the ARPES data presented, it does not explain the origin of the anomalous broadening of the QP lineshape as a function of binding energy observed in the nodal direction. AMRO measurements indicate that the FS of T12201 has a coherent, albeit weak, 3D structure [15]. Data analysis on ARPES spectra from cuprates is normally based on the assumption of a true 2D FS, neglecting the small c-axis dispersion. In a true 2D system, spectral features are not affected by the photon energy other than through changes in the scattering rates and matrix Chapter 2. ARPES on Tl2Ba2Cu06+s 26 elements. This feature is in sharp contrast to 3D systems, where the location and shape of spectral features change as a function of photon energy due to momentum conservation requirements. It is precisely momentum conservation, and a knowledge of the band structure of the unoccupied levels, that allow, in principle, the determination of the 3D FS by measuring spectra over a range of photon energies [7j. However, it has been shown that finite lifetimes in the unoccupied bands result in the ARPES FS crossings being spread over the projection of the FS onto the a — b plane at all photon energies, for realistic unoccupied band lifetimes [33]. Case studies on various HTSCs are presented by Markiewicz et al. [34]. The projection of the AMRO FS onto the a-b plane (Figure 2.7) reveals that at both the nodal and antinodal regions, there is no k2 dispersion. Thus, by the analysis of Bansil et al. [33], the kz dispersion should not affect the QP lineshape at either the nodal or the antinodal region, indicating that if the 3D character is responsible for the anomalous broadening of the nodal region QP peak as a function of binding energy or the nodal-antinodal reverse anisotropy, then the mechanism is not at all obvious. Another candidate for explaining the anomalous behaviour of this system is microscopic inhomogeneity. It has been shown through S T M measurements that on Bi2212, there is a strong inhomogeneity in the local density of states (LDOS) [35]. It is suggested by Pan et al. [35] that the the inhomogeneity in the bulk may give rise to a microscopic modulation in the gap size, and further, that averaging over a macroscopic spot on the sample, as is effectively done by ARPES, will produce a broadening in the antinodal region and will have little effect in the nodal region. Pan et al. [35] use this observation to explain the lineshape anisotropy around the FS in underdoped and optimally-doped cuprates. By analogous reasoning, microscopic inhomogeneity may be responsible for the observed broadening of the antinodal QPs towards lower binding energies. 2.3 Conclusion ARPES data taken on overdoped T12201 indicate two anomalous features. In the nodal region, the QP linewidths increase as binding energy is decreased. This is in contrast to what is expected from previous photoemission studies on optimally and underdoped cuprates, and from phase space arguments. The QP lineshapes are seen to be broader in the nodal regions than in the antinodal re-Chapter 2. ARPES on ThBa^CuOe+g 27 gions, in contrast to optimally and underdoped cuprates. The trend seen from comparing T12201-OD30 and T12201-OD63, together with previously reported LSCO data, suggest that the anisotropy reversal may be a generic feature of the cuprates. More measurements, especially with respect to temperature depen-dence and over a larger range of dopings, as well as theoretical work, is needed to properly interpret the trends seen from this experiment. Equally importantly, T12201 has been demonstrated to be an suitable system for single-particle spec-troscopic studies of the intrinsic properties of the doped CO2 plane. Future T12201 ARPES and scanning tunnelling microscopy work promises to progress our understanding of HTSCs, especially in the overdoped side of the phase di-agram. Chapter 3 28 Construction of a new ARPES system An in-house ARPES system is being constructed at UBC with the goal of im-proving both energy resolution (to 1.5 meV) and angular resolution (to 0.2°), with the highest possible sample positioning accuracy. This system is being designed to be coupled directly to an M B E such that samples can be grown and passed directly into the ARPES cyrostat without ever being exposed to pres-sures higher than 5 x 1 0 - 1 0 mbar. Connection to the M B E will allow ARPES to be done on the vast array of crystal structures that can be grown by M B E , rather than on the small range of crystals that can be cleaved in vacuo. CaO and NiO films, with the introduction of appropriate specific point defects, will be used to generate half-metallic ferromagnets and antiferromagnets, represent a new class of magnetic systems, and will be synthesized and studied, for in-stance. Since the samples grown by M B E are inherently thin films, systems with much higher resistivities will be able to be studied without the charging problems found in bulk crystals, so long as a conductive substrate is used. Beyond the advantages offered by a broader range of samples available for study, the MBE-grown samples offer a tuning parameter not available in single crystals - namely, the lattice constants. By choosing substrates with varying lattice constants, the strain, bond lengths and bond angles of the grown samples are varied accordingly. This allows the lattice constants on the thin films grown to be treated as an additional tuning parameter. In ARPES studies of single crystals, there is always a complication in the interpretation of the results due to the difficulty in separating the spectral components associated with the bulk states from those of the surface states. This difficulty is resolved in studies on thin films, as the concepts of bulk states and surface states are ill-defined in the limit of thin samples; all electronic states of the film are accessible from the surface, and all surface states effectively permeate the entire sample, provided Chapter 3. Construction of a new ARPES system 29 the film is only a few unit cells thick. 3.1 Elements of the new ARPES system The fundamental components of an ARPES system are an electron analyzer, a monochromatic photon source and a cryostat, which has to be designed both to bring the sample to the desired temperature and to be able to accurately move and rotate the sample. While analyzer resolutions, cryostat temperature mon-itoring accuracy, cryostat angle-setting accuracy and photon source linewidth set a limit on the accuracy of ARPES measurements by the system, the mea-surements can easily be compromised by a number of other factors, such as the thermal contact between the cold head of the cryostat and the sample itself, the quality of the vacuum, and, most importantly, residual electric and magnetic fields inside the analysis chamber, particularly those that vary in time. Intro-ducing the M B E to the system provides another design challenge in that the sample grown in the M B E must be able to be passed to the cryostat without exposing the grown surface to any contaminants. The design constraints used in designing each of these components are addressed. 3.2 Electron analyzer To determine the energy and angle of photoelectron emission, a hemispherical analyzer [36] - the Phoibos 150 CCD manufactured by SPECS - was chosen. The hemispherical analyzers used in modern ARPES experiments differ from those described in Moore et al. (2003) in that they have electrostatic lenses in front of the entrance slit, which are used both to change the energy of the incoming electron, and to Fourier transform the incoming electron spectrum, fo-cusing emitted at a given angle and energy to a unique location on the detection plane, regardless of the location of electron emission. The other major differ-ence is that analyzers used in ARPES have a 2D electron detector, consisting of a double-layer multichannel plate (MCP) [36] to amplify the electron signal, followed by a phosphor screen, onto which the electrons emitted from the MCP are accelerated. Light generated by the electrons hitting the phosphor screen is detected by a CCD camera. The implementation of a 2D electron detector al-lows energies moderately above and below the pass energies, as well as electrons coming in at angles off normal to be detected. Thus, the energy and emission Chapter 3. Construction of a new ARPES system 30 Figure 3.1: The UBC ARPES system (cryostat and transfer system not shown). Chapter 3. Construction of a new ARPES system 31 angle of an electron can be determined by the position where it is detected. The Phoibos 150 CCD has recently emerged as a competitive high-resolution electron analyzer. While it has yet to be used for ARPES studies on cuprates, the Phoibos 150 presents several advantages. The Phoibos 150, uses a double layer of /i-metal shielding to screen external magnetic fields, and uses titanium fasteners, which do not display ferromagnetism regardless of their history, inside the analyzer body to ensure that the lowest possible residual magnetic fields are maintained. Another major advantage of the Phoibos 150 is the use of machined hemispheres, as compared to the traditional formed hemispheres. Formed parts have much lower tolerances than machined parts [37], and introduce anisotropic strain in the formed metal [38], which can allow formed parts to deform as they stress-relieve over time, thus degrading analyzer accuracy. A unique feature of the SPECS analyzers is the approach taken with regards to interpretation of the positions of electrons detected on the 2D detector. This position, in general, is a nonlinear function of electron energy and angle, and this function changes as the pass energy and energy window of the analyzer are varied. The Phoibos 150 CCD is supplied with software that allows the characterization of the analyzer response function. This response function is inverted, allowing the SPECS software to return an intensity plot with angle and energy as linear and orthogonal coordinates. This procedure greatly simplifies analysis of the data, and is done in real time such that the experimenters can see clearly what they are measuring. 3.2.1 A n a l y z e r r e s o l u t i o n Test reports for our Phoibos 150 CCD electron analyzer show an ultimate an-gular resolution of 0.11° and an ultimate energy resolution of 1.0 meV. Since analyzer resolution is strongly affected by stray electric and magnetic fields within the analysis chamber, the analyzer was tested in our analysis chamber, in its final mounting position, to ensure that the measured resolution can in fact be realized in practice. The testing apparatus for angular resolution consisted of an electron gun, a stainless steel target and a slit array. Electrons emitted from the surface of the target pass through a slit array and into the analyzer. The slits have a width of 100 and are placed 35 mm from the target, corresponding to an angular opening of 0.16°. The F W H M of the beam from the SPECS EQ 22/35 electron gun is reported to be as small as 50 pm, corresponding to an angle of 0.08°, but Chapter 3. Construction of a new ARPES system 32 Figure 3.2: Schematic diagram depicting the analyzer angular resolution test apparatus. measuring the electron spot size at the time of testing was not possible. The smallest F W H M for the image of the slit detected by the analyzer during testing was 0.21°. Subtracting the contributions to this measured angular width due to the minimum electron spot size and the slit width gives an analyzer electron resolution of 0.11° according to the following equation: ar resolution — y/FWHM'_led ~ - FWHM^ w i d t h - FWHM?lectIon ~ Note that this value represents an upper limit for FWHM^g^^ resolution! since, without a direct measurement of the spot size from the electron gun, it is impossible to know with certainty that the gun was optimized to produce the reported minimum spot size. To produce monochromatic electrons for the energy resolution test, Xe atoms were bombarded with a He emission. The He lines have a F W H M of 1.0 meV, and Doppler broadening of the Xe target gas introduces a 3.3 meV width to the Chapter 3. Construction of a new ARPES system 33 emitted electrons. Considering the contributions of the He and Xe widths, the F W H M of the emitted electron linewidth as measured by the Phoibos 150 C C D of 3.6 meV corresponds to an analyzer energy resolution of 1.0 meV, as a result of the following equation: F W U M e s l e r g y resolution = ^ F W H M l e a s u r e d a n g l e - F W H M * C u v s o u r c e - F W H M ^ . This calculation, however, does not take into account the stray electric and magnetic fields produced by the Xe gas cell. The gas cell confines the Xe electro-magnetically, producing oscillation fields, which are detrimental to the analyzer resolution. The gas cell is designed such that these fields can be effectively can-celled outside of the gas volume, but the photoelectrons emitted from the Xe still need to pass through some region with oscillating fields before they leave the gas cell. As a result, the 1.0 meV quoted represents an upper bound on the true value of F W H M e n e l g y resolution-The impressive results of these tests not only indicate the potential of the Phoibos 150 CCD for ARPES studies, but demonstrate good shielding by the /i-metal analysis chamber. 3.3 Cryostat and manipulator The cryostat and manipulator present major design challenges. The ideal cryo-stat and manipulator combination allows the sample to be accurately positioned, with three spatial and three angular degrees of freedom, at an arbitrary tem-perature, without introducing any stray electric or magnetic fields and without contaminating the vacuum. Existing ARPES cryostats consistantly depart from this ideal in two impor-tant ways. First, the thermal contact between cold head and the sample is weak in two areas: the cold head and the rotating piece that holds the sample post is usually thermally linked through gears and copper braids, resulting in a poor thermal contact, and the clamping of the sample post to the piece that holds it is not typically sufficiently forceful to ensure good conductivity. Second, the rotation of the sample-post holder typically introduces a degree of angular un-certainty much larger than the instrument resolution, and differential thermal Chapter 3. Construction of a new ARPES system 34 expansion alters these angles as sample temperature is changed. The difficult task of avoiding these difficulties has been addressed through a joint initiative between the UBC ARPES group and Quantum Technologies, a Vancouver-based scientific instrument manufacturing firm specializing in cryogenics. To ensure good thermal contact between the cold head and the sample, the sample holder is clamped directly to the cold head, necessitating a rotat-ing cold head. This unconventional design feature presents challenges, but its realization will result in much more robust temperature control and lower ul-timate sample temperatures. To address the problem of sample positioning, a computer-numeric control (CNC) indexer is used to operate a parallelogram-style actuator that sets the sample angle, with ball-bearing pivots to eliminate hysteresis in angle-setting. As well as ensuring intrinsic mechanical accuracy of the cryostat, it is impor-tant to ensure that this accuracy not be degraded by allowing either deformation of the chamber, as a result of changing cryostat positions, or vibrations from the cryopump, to affect positioning accuracy. In order to ensure the rigidity of the chamber, only spherical and cylindrical elements are used in its construction. To block vibrations from the cryopump, the frame for the chamber is constructed from 125 mm diameter aluminum rod. A flow cryostat and manipulator for the UBC ARPES system has been designed and is under construction. The coordinate convention followed in the description of the cryostat is as follows: the x and y axes are parallel to the ground, x represents translation perpendicular to the analyzer lens, while y represents translation along the axis of the analyzer lens, z represents vertical translation.

= 0. x, y, z and motion are controlled with the x-y stage manufactured in-house and with custom and z stages manufactured by Pink Vacuum. 9 represents rotation about the x-axis when cj> = 0, and the 9 axis rotates with cf>. u> represents rotation about the normal to the sample, and hence, the w-axis rotates with both 9 and . 9 rotation is controlled by a CNC indexer, manufactured by HAAS, while u) rotation is accomplished manually. 9 and (j> are meant to be actuated continually during measurements, while w is meant to define the orientation of the sample, and thus is set at the beginning of a measurement (see Figure 3.3). Cryostat cooling is provided by liquid helium. Liquid He enters the cryostat through a transfer line into a phase separator. Helium gas is exhausted from the top of the phase separator, where it is used to cool the heat shield, and Chapter 3. Construction of a new ARPES system 3 5 CL5 Nitinol He tubes Sample clamping mechanism Capillary from mono-chromator and polarizer Phoibos 150 CCD electron analyzer lens Sample holder Silicon nitride bearings with titanium cages (Cerobear) Copper cold head XR-50 X-ray source (SPECS)-Figure 3 . 3 : Cryostat schematic and coordinate system. Chapter 3. Construction of a new ARPES system 36 exits the system. Liquid He leaves the bottom of the phase separator, through a flow-controlling needle valve and travels to the rotating cold head via a flexible tube. Exhaust He gas from the cold head is returned via a second flexible tube. 3.3.1 Cryostat materials The constraints of UHV-compatible materials and materials that do not gener-ate stray electric and magnetic fields greatly limit the choice of materials for the cryostat. UHV-compatible engineering materials are restricted to a few types of glass, some metals, some ceramics and a small number of other materials [36]. Furthermore, of the UHV-compatible metals appropriate for dynamic contact, which is needed for the angular positioning of the samples, most not ferromag-netic at room temperature undergo a ferromagnetic transition as they cool to temperatures appropriate for ARPES measurement, precluding their use. On top of these constraints, materials chosen must have the right thermal prop-erties - either good conducting or insulating behaviour - depending on their locations. Further, the thermal expansion coefficients of candidate materials must be considered to ensure that the system is not distorted as the cryostat temperature changes, to prevent deformation and failure of components, and to ensure that the sample position and angle are not affected by adjustments in temperature. Away from the cold head, temperatures are not as low, and therefore, ferro-magnetic transitions are less likely, and the presence of small magnetic moments is acceptable. Thus, for system components away from the cold head, 316 stain-less steel and UNS C10200 oxygen-free electronic copper were chosen for their vastly different thermal conductivities [39], with UNS C10200 having a thermal conductivity at all relevant temperatures more than 1000 times greater than 316. Further, the coefficients of thermal expansion of these materials are matched to within 10% at all relevant temperatures [40]. Near the cold head, temperatures are sufficiently low that stainless steel would undergo a magnetic transition if it were used; thus, it must be abandoned as a material choice. UNS C10200 is also abandoned in favour of the higher-purity alloy UNS C10100, as the conductivity near the sample is more critical. Titanium, 7075-T6 aluminum alloy and beryllium-copper are all used for smaller high-strength components in this area. The tubes carrying liquid He to the cold head endure a 3% deformation as the 0 angle is cycled. Very few metals have a significant fatigue life under Chapter 3. Construction of a new ARPES system 37 such strains. Further, most materials become more brittle as they are cooled from room temperature. Worse, the best spring materials are almost all steels, and thus are not usable due to their magnetism [41]. Fortunately, nitinol, a superelastic shape-memory nickel-titanium alloy, was found not only to meet, but to greatly exceed the design requirements. When nitinol is cooled below its transformation temperature to its martensite phase, it can undergo 10% deformation without any irreversible changes. Nitinol becomes more resistant to fatigue as it is cooled. While data is not available at cryogenic temper-atures, higher-temperature fatigue lifetimes of over 30000 cycles are reported for 3% strain. Given the rapid increase in fatigue life as the test temperature is reduced, it is reasonable to expect a fatigue life of over 107 cycles at typical measurement temperatures. Nitinol is also thermoformable, allowing the the de-sired tube shape to be fabricated in-house in an atmosphere-controlled furnace. Further, thermoforming temperatures between 300-500°C increase the transfor-mation temperature, resulting in better fatigue lifetimes at room temperature [42]. Measurements of magnetic properties of nitinol at cryogenic temperatures are not available in the literature. Thus, the magnetic properties of nitinol down to 2 K were investigated with a superconducting quantum interference device (SQUID). Minimal ferromagnetism was detected at these temperatures, and it was calculated to be insignificant compared to other stray magnetic fields in the chamber. It was not clear whether the origin of the ferromagnetism was intrinsic to the nitinol, the result of nickel inclusions, or due to ferromagnetic contaminants in the SQUID. The bearings used for the 6 rotation also presented demanding material constraints. To maintain UHV compatibility, the bearings cannot be lubricated. This restriction already presents a challenge for the bearing material, as vacuum galling and cold-welding occur readily without lubrication [36]. Further, the bearings have to provide a reliable thermal break between the heat shield on which they are mounted, which is maintained at ~100 K, and the cold head, which is designed to cycle between 2 and 300 K. The bearings must also be able withstand the differential thermal expansion between the inner and outer races at different temperatures. On top of these requirements, the bearing must also be non-magnetic. SisN 4 ceramic is used as a bearing material for applications requiring resistance to thermal shock, and is non-magnetic, although it does have a high thermal conductivity. Nonmetals do not suffer from the galling and cold-welding problems faced by metallic bearing surfaces, and outgassing in ceramics is generally not a problem [36]. In vacuum, however, the bulk of Chapter 3. Construction of a new ARPES system 38 the thermal resistance of composite objects is often due to the thermal contact between components. Engineering surfaces are never perfectly flat, and as a result, contact between two solid surfaces pressed together only takes place over a few small spots. For this reason, at low temperatures (where thermal radiation is not a dominant source of heat transfer) the conductance between mating surfaces depends on the size and number of these small contact points, which in turn depends on the pressure between the two surfaces. Conductance across solid interfaces is thus highly dependent on the clamping pressure. The conductance is found to depend approximately linearly on pressure [43]. SisN 4 ceramic is extremely hard (80 Rockwell C), so it is not unreasonable to expect the contact area, and hence the thermal conductivity, between two Si3N4 mating surfaces to be small despite the high thermal conductivity of the bulk material. With this line of reasoning in mind, the heat flow across a SisN 4 608 bearing with an inner and outer races at 66 and 4 K, respectively, was measured, and found to be 10 mW, rendering the heat load from the bearings much less than the calculated heat load from thermal radiation. Custom S13N4 607 ball bearings with titanium cages have been ordered from Cerobear for construction of the cryostat. 3.3.2 9 angle manipulation The 0 angle is set by a HAAS HA5C CNC indexer, which has a positioning ac-curacy of 0.008°. The top bar of the parallelogram and the indexer are mounted on top of the manipulator, outside of the vacuum. The moving vertical paral-lelogram arm is coupled to the vacuum space by edge-welded bellows, while the cryostat body and heat shield act as the stationary arm. The cold head itself acts as the lower parallelogram arm. The coefficients of thermal expansion of the vertical parallelogram arms are matched, and the arms are thermally tied together in numerous places to ensure matching temperatures, thereby removing differential thermal expansion problems from the vertical arms of the parallel-ogram. The temperature of the cold head is monitored accurately as part of the temperature-control feedback system, allowing corrections to the indexer angle due to differential expansion of the upper and lower arms to be calcu-lated and monitored on the fly. Analysis of the angular error caused by bearing clearances and differential thermal expansion not already taken into account are non-trivial, but even the most conservative analysis indicates that it is irrelevant compared to the angular resolution of the analyzer. Chapter 3. Construction of a new ARPES system 39 3.3.3 z translation z-motion is accomplished by a relatively standard manipulator. The differences between stock manipulators and the custom z-stage manufactured by Pink is mainly size. In order to minimize bending of the cryostat from uneven heat loads and to hold the complex manipulation system, a comparatively large diameter of 100 mm was chosen for the cryostat, which necessitated a larger z-stage. Further, the 21.8 kg mass of the CNC indexer, hanging over the edge of the manipulator, is large enough to distort the stock manipulators and degrade the angle-setting accuracy. Two massive 40 mm columns provide the Pink manipulator with the necessary stiffness. The 2-stage is equipped with a linear scale to allow computerized motion control. 3.3.4 cf> rotation Due to the size and weight requirements imposed by the CNC indexer and the z-stage, the rotation stage requires a larger bore and greater mechanical strength than standard rotation stages. Unlike normal rotation stages, where the load is placed on the seals, resulting in rapid seal-wear, high rotation forces and limited load-bearing capacity, the bearing force of the Pink stage is supported by a 220-mm-diameter 4-contact ball-bearing. The

stages, it is larger than commercially available stages. It is also equipped with linear encoders, although they are not used for feedback. In order to accommodate the larger stresses as a result of the large off-axis load and the vacuum pressure from the larger-area bellows, crossed cylindrical linear bearings are used, and in order to provide more robust and backlash-free positioning, ball-screws and ball-nuts are employed [44]. 3.3.6 Sample mounting and u rotation Samples are mounted on a copper \"bullet.\" The bullet must be grabbed from the rear by the sample transfer system, as surfaces grown by M B E are rapidly degraded if they face moving sample manipulation equipment. The cold head has a hole bored through it, into which the bullet is inserted. Holding the sample Chapter 3. Construction of a new ARPES system 40 from the rear necessitates a cryostat that will accept samples from the rear. While this presents some design challenges, it also offers unique opportunities. Having an unobstructed view of the front of the sample allows the use of low-energy electron diffraction (LEED) to monitor the orientation of the sample while the sample is rotated from the rear, allowing accurate sample positioning. Further, mechanisms for firm clamping and retraction of the bullet into the cold head can be mounted to the back of the cold head without interfering with electron trajectories. 3.3.7 Temperature control Diode temperature monitors are attached to the cold head and to the inside of the phase separator, which also contains a liquid-level sensor. Non-inductively wound heaters are located inside the phase separator and on the cold head. Below 4 K, the phase separator is filled with liquid, and only the heater on the cold head is used to control the temperature. The helium exhaust is pumped on in order to the reduce the liquid temperature to 2 K. At higher temperatures, liquid helium entering the cold head could undergo explosive boiling, resulting in temperature instability. Thus, above 4 K, the heater in the phase separator is used to eliminate liquid helium such that cooling of the cold head is done by gaseous helium. 3.4 Helium lamp and monochromator The UBC system uses a helium lamp as its UV source. The source used is the UVS 300, manufactured by SPECS. The UVS 300 can produce a photocurrent of 200 nA and has a linewidth of 1 meV. Photons from the UVS 300 enter a custom polarizing monochromator, also made by SPECS. The unique feature of the SPECS monochromator is that it allows rotation of the polarization, which is extremely valuable in ARPES studies due to the polarization dependence of the matrix elements. In order to expose the sample to maximal intensity, the photons from the monochromator are conveyed via a copper capillary to within 5 mm of the sample. The interior of the capillary is elliptical, to preserve polarization. The UV source system must be aligned to allow the photon spot to coincide with the analyzer focus. Given the impressive mass (~300 kg) of the system, the frame holding the lamp must be able to actively position the lamp, and Chapter 3. Construction of a new ARPES system 41 the motion must correspond to rotations about the centre of the flex coupling between the chamber and the UV source. A frame with these features has been designed in collaboration with SPECS, and has been manufactured by SPECS. 3.5 Conclusion The UBC ARPES system is expected to be a unique and powerful tool. Combin-ing an M B E with an ARPES system allows a much wider range of materials to be studied, compared with a conventional ARPES system. In order to achieve the required mechanical and thermal precision, several novel design features have been introduced, including the use of a rotating cold head, allowing direct thermal contact to the sample holder, the introduction of thermoformed nitinol tubing to allow non-magnetic UHV-compatible transfer of liquid helium to the cold head, and the use of Si3N,j ball-bearings as both a non-magnetic, UHV-compatible pivot point capable of operating at low temperatures, and as a ther-mal break. With excellent analyzer resolution, the ability to rotate polarization and a mechanically and thermally accurate cryostat with a broad temperature range extending to 2 K, the new ARPES system will allow MBE-grown samples to be studied, which could produce important results for correlated systems in general, including HTSCs. 42 Bibliography [1] Ian Falconer. Olivia Saves the Circus. Simon and Schuster, New York, 2001. [2] Werner Holzwarth and Wolf Erlbruch. The Story of the Little Mole Who Knew It Was None of His Business. David Bennet Books, London, 1994. [3] J. G. Bednorz and K. A. Muller. Possible high T c superconductivity in the Ba-La-Cu-0 system. Z. Phys. B: Condensed Matter, 64:189, 1986. [4] Neil W. Ashcroft and N. David Mermin. Solid State Physics. Brooks/Cole, Pacific Grove, CA, 1976. [5] Harald Ibach and Hans Lueth. Solid-State Physics. Springer, Berlin, 1995. [6] J. Orenstein and A. J. Millis. Advances in the physics of high-temperature superconductivity. Science, 288:468-474, 2000. [7] Stefan Huefner. Photoelectron Spectroscopy. Springer, Berlin, 1995. [8] Andrea Damascelli, Zahid Hussain, and Zhi-Xun Shen. Angle-resolved photoemission studies of the cuprate semiconductors. Reviews of Modern Physics, 75:473-541, 2003. [9] H. He, P. Bourges, Y. Sidis, C. Ulrich, L. P. Regnault, S. Pailhes, N. S. Berzigiarova, N. N. Kolesnikov, and B. Keimer. Magnetic resonant mode in the single-layer high-temperature superconductor T^BasCuOe+a. Science, 295:1045-1047, 2002. [10] H. Eisaki, N. Kaneko, D. L. Feng, A. Damascelli, P. K. Mang, K. M. Shen, Z.-X. Shen, and M. Geven. Effect of chemical inhomogeneity in bismuth-based copper oxide superconductors. Physical Review B, 69:064512, 2004. Bibliography 43 [11] Cyril Proust, Etienne Boaknin, R. W. Hill, Louis Taillefer, and A. P. Mackenzie. Heat transport in a strongly overdoped cuprate: Fermi liq-uid and a pure