Full Text

 Canadian Allis - Chalmers, Limited
*   HYDRAULIC TURBINES       STEAM TURBINES y^mmU^ TEXROPE    DRIVES      CENTRIFUGAL PUMPS
STEAM   ENGINES       OIL  ENGINES       GAS   ENGINES ^H        Ik FLOUR MILL MACHINERY       SAW   MILL MACHINERY
CONDENSERS '#! *-Jf BARKERS       FLEXIBLE   STAYBOLTS
MINING AND METALLURGICAL MACHINERY ^B AI R  COM PRESSORS       CONCAVEX
STEAM AND ELECTRIC  HOISTS ^HpC PENSTOCKS      TANKS
CRUSHING AND CEMENT MAKING  MACHINERY ^PF LOGGING AND   PULP   MACHINERY
CABLE address;"CANAC"toronto
HEAD OFFICE, 212   KIN G  STREET WEST
TORONTO,CANADA
Vancouver,  B.C*,
July 4th,   1930•
Mr,   J*  GrOldie,
Qkanagan Centre, B.C*
Dear Sir: RE: IRRIGATION PIMP
44Q acres - 330 ft*
QUTQATIOfl #1414
We wrote you under even date on pumping 120 acres,
280 ft, elevation and we will now go into the matter of
supplying "both the 400 acres and 120 acres with" a combined
unit. We have figured it out and find a one pump unit
the most feasible, "but will^how you how we figure it step
"by step, so that if we are wrong you will "be able to advise
us*
Figuring 2 Pump-
The lower pump at the lake should have capacity
enough to take care of the 400 acres above as well as the
120 acres lower down*
The 120 acres will require a pump of about 600 U.S*
G-*P*M* for 2-f acre feet (See other letter of this date)
The 400 teres at one acre foot will require a
pump with 700 U.S. G.P.M* and for th.6 two acre feet you
will require a" pump with capacity of 1400 U.S. G.P*M*
So, if you want 2 acre feet on the 400 acres, the
pump at the lake will have to be a 1400 gal* pump* Also,
the second pump will have to be this capacity/ And when pumping for the 400 acres there will be none for the 120 acres*
If you figure on pumping for the 120 acres for a few days, the
lower pump will be larger than you need for the 120 acres unless
you can take care of a large volume of water in a short time*
So* summing it all up, we feel that if you had a pump
of 1000 U.S. Gal* per minute, the lower pump will have capacity
for 1 acre foot for the 400 acres and about 1-|- acre feet for the
120 acres, both at the same time*  If irrigating each tract CANADIAN ALLIS-CHALMERS, LIMITED
Goldie* lg^ July 4th, 1930.
singly you will get enough for If- acre feet for the 400 acres and
then for the 120 acres you can shut down the discharge valve and
have plenty* To do this the lower pump will be 1000 U.S. gals.
per min - 3/4 mile - 280 feet elevation, and thesecond pump 1000
U.S. G.P.M* ~ 3/4 mile - 30 ft. elevation - discharge pipe 10".
We quote
LOWER
1 - Allis-Chalmers Centrifugal pump - bronze fitted,
Size 5n 3C 4W - Type MJ
2 Stage - Kingsbury type thrust
Capacity.- 1000 U.S. G.P*M* - 325 ft. head
Pump mounted on cast iron base, flexible coupling,
1 - Canadian General Electric motor - 125 HP -
1800 RPM , Type KT, 3 phase, 60 c^cle, 2200 Volt,
with hand starting compensator with overload and
undervoltage protection,
PRICE EET Your station  $3100*00*
BECOUP PUMP
1 - Allis-Chalmers Centrifugal Pump - bronze ditted,
Size 6" x Gn  - Type SF
Single stage - double suction-
Capacity - 1000 U.S. G.P.M. I 100 ft* head -
Pump mounted on cast iron base, flexible coupling,
1 - Canadian General Electric Co* - motor 40 HP -
1800 RBI, Type KT - 3 phase - 60 cycle. -
440 or 550 volts with hand starting compensator
with overload and undervoltage protection,
PRICE IIE.T Your station $ 930*00.
low, for a single pump unit at Woods Lake, with cape.city
for two acre feet on the 400 acre tract,ofwhich, if you do not
need so much, some can be piped off for the 120 acre tract.
1 - Allis-Chalmers Centrifugal Pump - bronze fitted -
Size 6 x 5 - Type MJ - 2 stage, Kingsbury type
Thrust, Capacity 1400 U.S. G.P*M. - Head - 400 ft*
1 - Canadian General Electric Co* motor - 200 HE -
l8O0 RPM I Type KT - 3 phase, 60 cycle - 2200 Volt*,
with hand starting compensator with overload and
undervoltage protection,
PRICE EET - Your Station * | 3800*00*
This price is slightly less than the two units but the
horse power of the two units together is less* CANADIAN ALLIS-CHALMERS, LIMITED
Mr* J. Goldie July 4th, 1930*
The equipment on which we have figured is the best
quality* we know of* Should you find we have not figured
the way you planned, we will go over it if you will let us
know* We shall be pleased to continue with you and figure
out your pumping proposition most carefully,
Yours very truly,
CANADIAN ALLIS-CHALMERS LIMITED
AEE:G VANCOUVER DISTRICT. J^j

Cite

Citation Scheme:

        

Citations by CSL (citeproc-js)

Usage Statistics

Share

Embed

Customize your widget with the following options, then copy and paste the code below into the HTML of your page to embed this item in your website.
                        
                            <div id="ubcOpenCollectionsWidgetDisplay">
                            <script id="ubcOpenCollectionsWidget"
                            src="{[{embed.src}]}"
                            data-item="{[{embed.item}]}"
                            data-collection="{[{embed.collection}]}"
                            data-metadata="{[{embed.showMetadata}]}"
                            data-width="{[{embed.width}]}"
                            async >
                            </script>
                            </div>
                        
                    
IIIF logo Our image viewer uses the IIIF 2.0 standard. To load this item in other compatible viewers, use this url:
http://iiif.library.ubc.ca/presentation/cdm.rainbow.1-0357922/manifest

Comment

Related Items