- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Theses and Dissertations /
- Towards real time EMG analysis
Open Collections
UBC Theses and Dissertations
UBC Theses and Dissertations
Towards real time EMG analysis Kenward, Gary Wayne
Abstract
Techniques for automatic recording and analyzing single motor unit action potentials in real time have been studied. A model of the human motor unit has been derived. The muscle fibers were modelled with current dipoles and randomly distributed within the motor unit cross section according to a bivariate Gaussian, or binormal, probability density function. Computer simulations were performed with the model using parameters measured for the human biceps brachii. The single fiber action potentials generated by the current dipoles were summed at a recording site to produce a simulated single motor unit action potential. Analysis of the motor unit model and the potentials generated showed that the single motor unit action potentials of interest were recorded from well within the motor unit territory, and that the potentials formed were influenced mainly by the nearby fibers. The single motor unit action potential amplitude and duration were found to have a non-linear dependence upon the radius of the recording site from the motor unit center. The relationship between amplitude and duration was found to be linear but subject to random variations due to the influence of nearby fibers. The behaviour of the simulated single motor unit action potentials agreed with clinical observations. A three stage real time processing system was designed. The signal characteristics of clinically recorded electromyographic activity at low contraction levels were analyzed, and the first stage of pre-filtering designed to reduce the required sampling rate, and increase the signal to noise ratio without distorting the single motor unit action potentials. The second stage of processing was based on an adaptive matched filter with dual detection thresholds. The final stage used feature classification of the detected single motor unit action potentials to remove potentials not from the selected motor unit. A non-real time software implementation of the processing system demonstrated that large ensembles of single motor unit action potentials could be acquired from relatively short recordings of electromyographic activity, with few detection errors.
Item Metadata
Title |
Towards real time EMG analysis
|
Creator | |
Publisher |
University of British Columbia
|
Date Issued |
1982
|
Description |
Techniques for automatic recording and analyzing single motor unit action potentials in real time have been studied. A model of the human motor unit has been derived. The muscle fibers were modelled with current dipoles and randomly distributed within the motor unit cross section according to a bivariate Gaussian, or binormal, probability density function. Computer simulations were performed with the model using parameters measured for the human biceps brachii. The single fiber action potentials generated by the current dipoles were summed at a recording site to produce a simulated single motor unit action potential. Analysis of the motor unit model and the potentials generated showed that the single motor unit action potentials of interest were recorded from well within the motor unit territory, and that the potentials formed were influenced mainly by the nearby fibers. The single motor unit action potential amplitude and duration were found to have a non-linear dependence upon the radius of the recording site from the motor unit center. The relationship between amplitude and duration was found to be linear but subject to random variations due to the influence of nearby fibers. The behaviour of the simulated single motor unit action potentials agreed with clinical observations. A three stage real time processing system was designed. The signal characteristics of clinically recorded electromyographic activity at low contraction levels were analyzed, and the first stage of pre-filtering designed to reduce the required sampling rate, and increase the signal to noise ratio without distorting the single motor unit action potentials. The second stage of processing was based on an adaptive matched filter with dual detection thresholds. The final stage used feature classification of the detected single motor unit action potentials to remove potentials not from the selected motor unit. A non-real time software implementation of the processing system demonstrated that large ensembles of single motor unit action potentials could be acquired from relatively short recordings of electromyographic activity, with few detection errors.
|
Genre | |
Type | |
Language |
eng
|
Date Available |
2010-04-13
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
|
DOI |
10.14288/1.0095332
|
URI | |
Degree | |
Program | |
Affiliation | |
Degree Grantor |
University of British Columbia
|
Campus | |
Scholarly Level |
Graduate
|
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.