South Campus Stormwater Detention Facility Detailed Design Report Rizzo, Kayle; Stewart, Jason; Mann, Tyler; Eccles, Jordan; Dhillon, Dilveer; Luk, Brian 2016-04-08

Your browser doesn't seem to have a PDF viewer, please download the PDF to view this item.

Notice for Google Chrome users:
If you are having trouble viewing or searching the PDF with Google Chrome, please download it here instead.

Item Metadata

Download

Media
18861-Rizzo_K_et_al_SEEDS_2016.pdf [ 3.48MB ]
Metadata
JSON: 18861-1.0343393.json
JSON-LD: 18861-1.0343393-ld.json
RDF/XML (Pretty): 18861-1.0343393-rdf.xml
RDF/JSON: 18861-1.0343393-rdf.json
Turtle: 18861-1.0343393-turtle.txt
N-Triples: 18861-1.0343393-rdf-ntriples.txt
Original Record: 18861-1.0343393-source.json
Full Text
18861-1.0343393-fulltext.txt
Citation
18861-1.0343393.ris

Full Text

 UBC Social Ecological Economic Development Studies (SEEDS) Student ReportSouth Campus Stormwater Detention FacilityDetailed Design ReportBrian Luk, Dilveer Dhillon, Jason Stewart, Jordan Eccles, Kayle Rizzo, Tyler Mann University of British ColumbiaCIVL 446April 08, 20162018 Disclaimer: “UBC SEEDS Program provides students with the opportunity to share the findings of their studies, as well as their opinions, conclusions and recommendations with the UBC community. The reader should bear in mind that this is a student project/report and is not an official document of UBC. Furthermore readers should bear in mind that these reports may not reflect the current status of activities at UBC. We urge you to contact the research persons mentioned in a report or a SEEDS team representative about the current status of the subject matter of a project/report”.UBC SEEDS Sustainability Program April 08, 2016 Proponent Team 11 Kayle Rizzo Jason Stewart Tyler Mann  Jordan Eccles Dilveer DhillonBrian Luk "$#$""#!&#!###(#"!!#!&6,2*5/.+1035/4.0-4,  KREW Hydraulic Consulting Ltd. '$#%"$!(Stormwater modeling has indicated that significant flooding may occur on the University of British Columbia’s (UBC) South Campus under an intense rainfall. This is of concern to the university, since the quantity and quality of stormwater from such an event may cause damage to UBC assets and also threaten streams that carry this water to the ocean. A 10-year or 100-year flood on campus could lead to cliff failure along the southeast banks due to erosion, and may also damage the riparian habitat. An improved stormwater management system is required to mitigate flooding and environmental damage during large storms. KREW Hydraulic Consulting has developed a detailed design for a stormwater detention facility that manages the 10-year and 100-year stormwater flows from the South Campus at UBC. Some of the key criteria and considerations in the development of the detailed design include effectively designing the stormwater detention tanks, achieving LEED Gold water treatment requirements, and planning the construction of the retention pond.  The design consists of three underground detention tanks strategically placed throughout the south catchment and a single large retention pond. The underground detention tanks are located at Thunderbird Arena, the RCMP parking lot, and Save-On-Foods. The retention pond is situated near the intersection of SW Marine Dr. and Wesbrook Mall, as this location will allow the pond to collect and store water from all regions of the catchment.  The detention tanks are sized to hold water from a 25-year flood event, and the retention pond is large enough to handle any additional water above a 25-year and up to a 100-year flood event. By utilizing underground retention tanks, it is ensured that the retention pond remains dry for the majority of rainfall events, allowing the retention pond to be used for storage and other site operations. A treatment system will be implemented to ensure the stormwater will meet all environmental regulations and requirements before it is discharged into the ocean.  KREW Hydraulic Consulting has completed the detailed design report, which includes final construction plans and specifications for the performance of the stormwater detention system. Detailed engineering calculations and drawings for the project are included as appendices. The current construction schedule consists of 128 working days from May to October 2016, and the total cost of the project is approximately $2.54 million.  - i - KREW Hydraulic Consulting Ltd. 	 Executive Summary ........................................................................................................... i1 Introduction ................................................................................................................ 12 Project Design Criteria ............................................................................................... 22.1 Technical Requirements ..................................................................................... 22.1.1 Flood Volume Reduction ........................................................................ 22.1.2 Water Quality Control ............................................................................. 22.1.3 Erosion Management ............................................................................... 32.2 Environmental Constraints ................................................................................. 32.3 UBC Policies ...................................................................................................... 32.4 Government Regulations .................................................................................... 32.5 Construction Planning Requirements ................................................................. 42.6 Societal Impacts & Public Engagement ............................................................. 43 Design Description ..................................................................................................... 63.1 Design Overview ................................................................................................ 73.2 System Layout .................................................................................................... 73.3 Design Advantages ........................................................................................... 114 Hydrological Analysis .............................................................................................. 124.1 Stormwater Modelling & Analysis ................................................................... 124.2 Flood Volume Analysis .................................................................................... 124.3 System Flow Capacity ...................................................................................... 135 Geotechnical Analysis .............................................................................................. 155.1 Lateral Earth Pressure ....................................................................................... 155.2 Bearing Capacity .............................................................................................. 165.3 Liquefaction & Settlement Assessment ............................................................ 166 Structural Design ...................................................................................................... 176.1 Concrete Mix Design ........................................................................................ 176.2 Structural Loading & Analysis ......................................................................... 186.3 Structural Concrete Design ............................................................................... 196.3.1 Slab Design ............................................................................................ 196.3.2 Slab Band Design .................................................................................. 206.3.3 Column Design ...................................................................................... 206.3.4 Perimeter Wall Design .......................................................................... 206.3.5 Strip Footing Design ............................................................................. 20  - ii - KREW Hydraulic Consulting Ltd.  7 Stormwater Treatment .............................................................................................. 227.1 Stormceptor Overview ...................................................................................... 227.2 Stormceptor Sizing ........................................................................................... 238 Retention Pond Design ............................................................................................. 268.1 Design Components .......................................................................................... 278.1.1 Forebay .................................................................................................. 288.1.2 Emergency Overflow ............................................................................ 288.1.3 Berm Embankment / Slope Stabilization .............................................. 288.1.4 Basin Dewatering .................................................................................. 288.2 Maintenance ...................................................................................................... 299 Construction Work Plan ........................................................................................... 309.1 Construction Site: Tank 1 ................................................................................. 319.2 Construction Site: Tank 2 ................................................................................. 329.3 Construction Site: Tank 3 ................................................................................. 339.4 Construction Site: Retention Pond .................................................................... 3410 Project Schedule ....................................................................................................... 3511 Detailed Cost Estimate ............................................................................................. 3712 Conclusion & Recommendations ............................................................................. 3913 References ................................................................................................................ 40Appendix A – Project Drawings ..................................................................................... 42Appendix B – Hydrological Design Calculations ........................................................... 51Appendix C – Geotechnical Design Calculations ........................................................... 53Appendix D – Structural Design Calculations ................................................................ 56Appendix E – Detailed Project Schedule ........................................................................ 60Appendix F – Detailed Cost Estimate ............................................................................. 63Appendix G – Site Photos ............................................................................................... 66Appendix H – Stormceptor Sizing & Design ................................................................. 68  - iii - KREW Hydraulic Consulting Ltd. 	 Figure 1: UBC South Catchment Overview ..................................................................... 6Figure 2: Underground Detention Tank Locations ........................................................... 8Figure 3: Retention Pond Location ................................................................................... 9Figure 4: Soil Stratigraphy & Properties used for Design .............................................. 15Figure 5: Gravity Loading On Detention Tank ............................................................... 18Figure 6: Detention Tank Top Slab Moment Diagram ................................................... 19Figure 7: 3D Detention Tank Model ............................................................................... 21Figure 8: Traditional 3-Chamber Oil/Grit Separator ...................................................... 22Figure 9: Stormceptor STC ............................................................................................. 23Figure 10: Stormceptor MAX ......................................................................................... 25Figure 11: Retention Pond & Filtration System Model .................................................. 26Figure 12: 2D Retention Pond Schematic Drawing ........................................................ 27Figure 13: Tank 1 Site Plan ............................................................................................ 31Figure 14: Tank 2 Site Plan ............................................................................................ 32Figure 15: Tank 3 Site Plan ............................................................................................ 33Figure 16: Retention Pond Site Plan ............................................................................... 34Figure 17: UBC ISMP Project Milestones ..................................................................... 35Figure 18: Rainfall Intensity Chart Indicating Design Intensity ..................................... 51Figure 19: Catchment Area of Each Retention Unit ....................................................... 52Figure 20: Location Of Detention Tank 1 ....................................................................... 66Figure 21: Location Of Detention Tank 2 ....................................................................... 66Figure 22: Location Of Detention Tank 3 ....................................................................... 67Figure 23: Location Of Retention Pond .......................................................................... 67    - iv - KREW Hydraulic Consulting Ltd. 	 Table 1: Team Member Contributions .............................................................................. 1Table 2: Government Laws & Regulations ...................................................................... 4Table 3: Stakeholder Groups & Stakeholders ................................................................... 5Table 4: Retention Tank and Pond - Dimensions and Locations .................................... 10Table 5: Common Impervious Fraction .......................................................................... 12Table 6: Runoff Coefficients .......................................................................................... 13Table 7: Retention Unit Outlet Discharges ..................................................................... 14Table 8: Retention Unit Outlet Pipe Size ........................................................................ 14Table 9: Structural Element Sizes & Dimensions ........................................................... 21Table 10: Input Data for PCSWMM for Stormceptor .................................................... 23Table 11: Stormceptor Model Recommendation Provided by PCSWMM .................... 24Table 12: Stormceptor STC 14000 Capacity .................................................................. 24Table 13: Summary of Maintenance Requirements ........................................................ 29Table 14: Detailed Design Cost Estimate Summary ....................................................... 37Table 15: Annual Estimated Operations and Maintenance Cost .................................... 38Table 16: Average Time of Concentration At Southern Outfall ..................................... 51Table 17: Area of Catchment for Each Retention Unit ................................................... 52Table 18: Detailed List Of Project Tasks ........................................................................ 60Table 19: Detailed Cost Estimate Sheet .......................................................................... 63 - 1 - KREW Hydraulic Consulting Ltd.  #!$#The University of British Columbia’s South Campus is at risk of significant flooding, which may cause damage to UBC assets and threaten streams carrying this water to the ocean. The quality and quantity of stormwater in a 10-year (Q10) and 100-year (Q100) flood event could damage the riparian habitat and can cause cliff erosion. A stormwater detention facility located in the University’s South Campus would reduce or eliminate the risks imposed by an extreme flood event.  This report presents the detailed design for a stormwater management system, which will mitigate flooding on UBC’s South Campus under intense rainfalls. Section 2 discusses the key project constraints and specific design criteria. Section 3 presents a full description and rationale for the detailed design. Sections 4 to 8 provide detailed design information relating to the hydrological, geotechnical, structural, and environmental design aspects. Sections 9, 10 and 11 present the construction work plan, project schedule and cost estimate, respectively. The following table outlines each team member's contributions to the various tasks and roles in the development of the detailed design report. Table 1: Team Member Contributions Tasks & Roles Team Members   Introduction & Formatting   Kayle Rizzo   Projects Constraints   Brian Luk, Kayle Rizzo   Hydrological Analysis   Tyler Mann   Geotechnical Analysis   Jason Stewart   Structural Design   Kayle Rizzo   Stormwater Treatment   Brian Luk   Retention Pond Design   Dilveer Dhillon   Project Schedule   Jason Stewart   Work Plan & Cost Estimate   Jordan Eccles   - 2 - KREW Hydraulic Consulting Ltd.  !#"!#!This section provides a description of the key issues, the design criteria, and the approaches taken to successfully meet the design requirements. The following sub-sections outline the technical requirements, environmental constraints, societal impacts, UBC policies, government regulations, and construction planning requirements.  #! $!#"The stormwater management system is required to control the quality and quantity of stormwater in a 10-year and 100-year flood event. The primary technical requirements include flood volume reduction, water quality control, and erosion management.   %$!$#The stormwater detention system must reduce the total runoff volume caused by increased urban development and subsequent impervious areas. Additionally, the water collected over natural pervious areas (such as fields and forested areas) should be returned to shallow groundwater via infiltration. As a result, the design will incorporate stormwater storage in three detention tanks and a retention pond to provide sufficient stormwater collection capacity for large flood events. Furthermore, the design addresses the issue of minor flooding at Wesbrook Mall and Marine Drive during a 10-year event and the significant flooding and property damage during a 100-year event. In order to minimize the risk of overland flows, detention tanks are strategically placed across South Campus.  &#! $#(#!The stormwater detention system should control the quality of stormwater runoff. Past contaminant testing indicates that UBC’s stormwater runoff contains sediment and metals that are potentially harmful to the surrounding ecosystem. The use of stormwater filtration systems has been implemented in the detailed design to meet the water quality requirements.   - 3 - KREW Hydraulic Consulting Ltd.  !"#The stormwater detention system should restrict the post-development peak runoff flow rate to match the volume, shape and peak rate of pre-development flows during 24-hour precipitation events (Chilibeck & Sterling, 2001). By limiting the runoff flow rate during precipitation events, pipe and cliff erosion can be minimized. The flow rate of runoff is managed by the introduction of a flow monitoring and control system within the pipe network.  %!#"#!#"The detention facility will be implemented according to the design guidelines provided by the UBC Vancouver Campus Plan. These guidelines require LEED Gold Standard as a minimum for this system and reaching LEED Platinum Standard is encouraged. Specific to this project, LEED Credits SSc6.1 and SSc6.2 (standards for stormwater management) are mandatory for this facility. Metro Vancouver has developed an Integrated Stormwater Management Plan (ISMP) to ensure environmental quality and protect communities from localized flooding. While UBC is not subject to Metro Vancouver’s regulation, the stormwater detention facility has been developed using Metro Vancouver’s ISMP as a reference.  $"UBC’s Vancouver campus lands are located in the unorganized territory of the Greater Vancouver Regional District (Metro Vancouver) and as such are outside of government jurisdiction. The stormwater detention facility has been designed in accordance with the planning policies and development controls established by UBC. The project adheres to the requirements outlined in the UBC Vancouver Campus Plan and the UBC Land Use Plan. 	 %!#!$#"The stormwater management system meets the government laws and regulations shown in Table 2. The system complies with the following regulations and has been designed according to their requirements.  - 4 - KREW Hydraulic Consulting Ltd. Table 2: Government Laws & Regulations Level of Government Applicable Regulations Federal Government • Fisheries Act • Canadian Environmental Protection Act Provincial Government • Water Act • Environmental Management Act   "#!$#! $!#"A building permit is required for all construction regulated under the BC Building Code and the UBC Development & Building Regulations. As the construction value of the project exceeds $2.5 million, an independent Coordinating Code Consultant (CCC) will be contracted to perform a third-party review for compliance with the Building Code as required by Campus & Community Planning. Section 9 of the report provides detailed information regarding the construction work plan.   "##"$#To implement a stormwater management system to serve the campus community’s needs, KREW Hydraulic Consulting offered the public an opportunity to provide feedback on the proposed detention facility. A public information session was held on October 20th and an online consultation was available from October 15th to October 22, 2015. The information collected from the information session and online survey has been thoroughly considered during the preliminary design phase. KREW Hydraulic Consulting has identified the stakeholder groups presented in Table 3 as requiring information and consultation throughout the duration of the project.    - 5 - KREW Hydraulic Consulting Ltd. Table 3: Stakeholder Groups & Stakeholders Stakeholder Groups Stakeholders Client • University of British Columbia Community • University Neighbourhoods Association • Pacific Spirit Park Society Government • B.C. Ministry of Transportation and Infrastructure • Metro Vancouver Sewage and Drainage District   KREW Hydraulic Consulting will provide notification to the stakeholders through email, phone calls and in-person meetings throughout the duration of the project. Additionally, public information will be provided on the UBC website and updated on a weekly basis.   - 6 - KREW Hydraulic Consulting Ltd.  ""!#The stormwater retention system will consist of three underground concrete detention tanks and a single retention pond located strategically throughout the south campus. The design will mitigate flooding across the south campus and reduce erosion at the outfalls during intense rainfalls. All upgrades to the existing stormwater system will be confined to the south campus catchment, as shown in Figure 1 below.  Source: Adapted from Google Maps Nov 2015  Figure 1: UBC South Catchment Overview    - 7 - KREW Hydraulic Consulting Ltd.  "%!%&The following bullet points illustrate the key features of the optimized design: • Multiple underground detention tanks, throughout the catchment prevent the system from backing up and overflowing at any location. • Strategic tank placement will minimize the need to reroute pipes, which will in turn reduce cost. • Retention pond allows design to maintain versatile and usable green space while providing a large water storage capacity for intense rainfall events. • Grit separator and filtration system will ensure quality of stormwater effluent.   "("#($#In order to prevent localized flooding in any region of the south catchment, the detention tanks were dispersed through the entire catchment. Currently there are two existing underground detention tanks in the south campus catchment. One tank is located under Nobel Park and the other under the TRIUMF laboratories. Therefore, the locations of the three new underground tanks were chosen such that they could collect and store stormwater in the other regions of the catchment.  The three new underground tanks are all located north of the existing tanks. Utilizing this tank layout allows the water which falls in the upper portion of the catchment to be collected and stored immediately. This approach allows the existing tanks to better serve their own portion of the catchment and prevents back-ups and flooding due to the existing flow capacity of the system.  An overview of the locations of the three underground detention tanks is provided in the following figure.  - 8 - KREW Hydraulic Consulting Ltd.  Source: Adapted from Google Maps Nov 2015 Figure 2: Underground Detention Tank Locations  The total storage capacity of the existing and new underground tanks will allow the retention pond to remain dry in all flood events up to a 25-year (Q25) event. This will provide an opportunity for UBC’s Plant Operations to utilize the pond as a storage facility. As shown in Appendix A, the retention pond will have a bypass pipeline and flow valve placed ahead of the pond connecting directly to the outfall, to ensure the pond remains dry during floods up to a Q25 event. The flow rate and storage capacity of the system will be monitored to give warning when the retention pond is required for stormwater storage. The retention pond is located near the intersection of SW Marine Dr. and Wesbrook Mall for two reasons. Firstly, under intense flood events the pond will be able to collect and store water from all regions of the south catchment. Secondly, the location of a retention pond requires a relatively large open space with minimal interference, which is provided in  - 9 - KREW Hydraulic Consulting Ltd. the southern most part of the catchment. An overview of the location of the retention pond is shown in Figure 3 below.   Source: Adapted from Google Maps Nov 2015 Figure 3: Retention Pond Location  The 2D design drawings showing the layout and dimensions of the detention tanks and the retention pond can be found in Appendix A. Site photos for the locations of the detention tanks and retention pond are presented in Appendix G. The dimensions and locations of the three underground detention tanks and retention pond are summarized in the the following table.    - 10 - KREW Hydraulic Consulting Ltd. Table 4: Retention Tank and Pond - Dimensions and Locations  Dimensions Location Tank 1 (Thunderbird Arena Tank) Length – 16 m Width – 16 m Depth – 2 m Tank Volume – 500 m3 Southwest of Wesbrook Mall and Thunderbird Boulevard. South of Doug Mitchell Thunderbird Sports Center. Tank 2 (RCMP Parking Lot Tank) Length – 15 m Width – 15 m Depth – 2 m Tank Volume – 450 m3 Northeast of Westbrook Mall and Hampton Place. UBC RCMP Parking Lot. Tank 3 (Save On Foods Tank) Length – 19 m Width – 19 m Depth – 2 m Tank Volume – 750 m3 Forested area southeast of the roundabout connecting Wesbrook Mall and West 16th Avenue. Retention Pond Slope- 1:3 Top Length – 60 m Top Width – 60 m Bottom Length – 45 m Bottom Width – 45 m Pond Volume – 6400 m3 Forested area northwest of SW Marine Drive and Wesbrook Mall intersection.   A combination of corrugated high-density polyethylene (HDPE) pipe and reinforced concrete pipe (RCP) will be used to connect the tanks to the existing stormwater system. The decision to use HDPE or RCP will be based on the compatibility of the existing pipe being connected. The length of this additional piping will vary for each of the tank locations, and will depend on the distance of the tanks from the main pipe network. HDPE piping will also be used to construct the bypass line for the pond.  - 11 - KREW Hydraulic Consulting Ltd.  "%#"The underground retention tanks are sized to hold water from a Q25 flood event and the retention pond is large enough to handle any additional water above a Q25 and up to a Q100 flood event. By utilizing underground retention tanks, it is ensured that the retention pond remains dry for the majority of rainfall events, allowing the retention pond to be used for storage and other site operations. The detailed design also has the following benefits: • Prevents localized flooding in all regions of the south catchment. • Limits alterations to the existing stormwater collection system. • Removes oil and grit efficiently from the stormwater run-off. • Minimizes concrete requirements during construction, therefore reducing the project’s CO2 emissions. • Controls system outflow which mitigates cliff erosion. • Creates natural retaining system through use of retention pond.    - 12 - KREW Hydraulic Consulting Ltd. 	 (!(""This section provides a description of the stormwater modelling, flood volume analysis, and system flow rate calculations. 	 "#!&#!(""To obtain the needed flood data for analysis, the rain fall intensity of a Q100 storm event had to be determined. This analysis was started by calculating the time of concentration for the existing system in the southern catchment. Using SWMM software, constant rainfalls were modeled for a period of 24 hours while monitoring the outfalls for constant discharge. The time taken to get a constant discharge was recorded as the time of concentration for that rainfall intensity. After multiple trials an average value of 6 hours was calculated. The rainfall intensity for a Q100 storm event was determined using the calculated time of concentration in conjunction with a duration-intensity graph and was found to be 10mm per hour for a duration of 6 hours. The calculations for the time of concentration and rainfall intensity can be found in Appendix B. 	 %$(""To obtain flood runoff volumes, a runoff coefficient needed to be determined. Using satellite images, the non-permeable and developed areas of the catchment were summed to find the total area of non-permeable ground. In order to accommodate for the expected future development in the southern catchment, the area of non-permeable ground was increased by 25%. The impervious fraction was then calculated to be 0.27 using the ratio of non-permeable area to the total area of the catchment. The impervious fraction was used to determine the land classification from Table 5 below. Table 5: Common Impervious Fraction  Source: Richmond Storm Drainage Guidelines  - 13 - KREW Hydraulic Consulting Ltd. Based on the previous table the land classification was determined to be at the upper end of parks and agricultural. Using Table 6, a runoff coefficient of 0.3 (30%) was selected as the most suitable option. Table 6: Runoff Coefficients  Source: Richmond Storm Drainage Guidelines Taking the total area of the catchment to be approximately 1.8km2, a total rainfall intensity of 10mm/hr for a duration of 6 hours, and having only 30% of the storm water reach the catchment system, the flood volume was calculated to be 32000 m3.  	 "("#&#(Using the calculated flood volume and assumptions in the following paragraph, the volume and discharge of each tank was calculated. In efforts to determine the maximum allowable discharge of each tank, calculations were performed assuming the tank is full, therefore providing the maximum head and flow. Additionally, the rainfall intensity was considered constant over the entire catchment area.  After determining feasible locations for each of the tanks, the catchment area upstream of each tank was determined. The area ratio of each tank catchment was individually multiplied by the total system discharge. This provides a retention unit size that is capable of holding all stormwater upstream in the system, while discharging stormwater at a rate that meets the discharge restrictions of the outfall. These area ratios and tank sizes can be found tabulated in Appendix B.  - 14 - KREW Hydraulic Consulting Ltd. A key design requirement is maintaining a low discharge velocity at both of the system outlets, to minimize erosion and eliminate the requirement of rip-rap and armoring. Using Vancouver’s storm drainage guidelines, the discharge velocity is restricted to a maximum 1 m/s. In order to maintain a conservative design, the discharge velocity used was 76% of the maximum, resulting in a system discharge velocity of 0.76 m/s. The discharge of each retention unit was designed based on the total system discharge. The tank discharge was selected based on the incoming flow and the tank size. Using these parameters, different flows were analyzed through an iterative procedure until the desired results were obtained. The outlet discharge of each retention unit can be seen in Table 7. Table 7: Retention Unit Outlet Discharges Tank Size (Original) m3 Drainage (m3/hr) 1 500 350 2 450 315 3 750 525 Existing 2100 1474 Pond 6400 1025  To adequately control the discharge of each retention unit a restricted pipe diameter was used. The pipe diameter is determined based on the tank discharge, making each tank an outlet controlled unit. As it is infeasible to replace all the pipes in the system only a small length of pipe after the tank will be replaced, creating a restriction until the water feeds into the mainline. Using orifice flow principals and solving for the pipe area, the required pipe diameter was determined. It should also be noted that a vena contracta of 0.611 was used in design and sample calculations can be found in Appendix B. The following table outlines the required outlet pipe size to achieve the needed discharge from each tank. Table 8: Retention Unit Outlet Pipe Size Tank Q (m3/hr) Diameter (m) 1 350 0.19 2 315 0.18 3 525 0.23 Pond 1025 0.37  - 15 - KREW Hydraulic Consulting Ltd.  #(""KREW Hydraulic Consulting has used given borehole data to estimate soil properties, and corresponding loads on the underground detention tanks. Due to the lack of borehole logs near our proposed locations, KREW would recommend completing two more logs to acquire more robust data to accurately model bearing capacity, as well as completing a liquefaction assessment.   #!!#!""$!To prevent side-wall failure of the detention tanks, the side walls are designed based on the factored lateral earth pressures. Live loads above the tank also have a horizontal component, however we have assumed that with a 1m depth of cover, the horizontal magnitude of the live loads will be negligible. It should be noted that only the empty scenario of the retention tank has been included, as this is the governing loading case. The following figure presents the soil stratigraphy used in the geotechnical design.    Layer Soil Description Depth (m) Thickness (m)   (kN/m3) 	 '(°) Ka 1 Well graded sand 0 - 0.5 0.5 18.5 33 0.295 2 Gravel with medium sand 0.5 - 0.7 0.2 19.5 35 0.271 3 Sand with trace silt 0.7 - 1.5 0.8 18 30 0.333 4 Sand, gravel, trace silt 1.5 - 3.0 1.5 18 32 0.307  Source: Jason Stewart (Feb 2016) Figure 4: Soil Stratigraphy & Properties used for Design   - 16 - KREW Hydraulic Consulting Ltd. In the borehole log data, the water table was shown at a 2m depth below the surface. As our proposed retention tank locations are not exactly where the borehole was recorded, the water table was assumed to be just below the ground surface to account for any uncertainty and seasonal changes. Furthermore, this increases the lateral earth pressure applied to the side of the tank, decreases the bearing capacity of the soil, and increases the liquefaction potential, thus making it the governing design scenario. The total lateral earth pressure along the side wall of the retention tank was found to be 30 kN/m3.  !#(The detention tanks were designed on the assumption that slab-on-grade construction would be acceptable due to the large bearing area of the tanks. A full bearing capacity calculation can be found in Appendix C. Initially, a factor of safety of 1.5 was used for the reduction of the allowable load, however an additional factor of safety of 2 was applied to account for the water table being above the structure. Overall, a factor of safety of 3 was used. As mentioned above, more borehole log data should be collected to decrease the uncertainty in the actual soil conditions below the tank. If soft clays or weak soil are present below the tank, ground improvement methods such as vibro/dynamic compaction may be necessary.   $#"###""""#KREW Hydraulic Consulting did not perform a liquefaction assessment due to the lack of data below the slab-on-grade elevation of 3 meters. During a seismic event, loose granular soils lose their shear strength due to cyclic loading. Consequently, structures built on these soils are at risk of collapse or failure; although the consequence of a tank failing during a seismic event is low to the public, the cost (quantitative risk) associated with the tank failure is high. Therefore, densification may be required to decrease liquefaction potential. If there are fine grained soils below the tank, settlement will have to be assessed. Depending on the percentage of fines and stress history, surcharge loading will be required to achieve consolidation. It should be noted that elastic settlement can also occur in sands, however this is less of a concern in the proposed excavation locations, as most of them have been paved and would have undergone some compaction for previous road construction and pavement.  - 17 - KREW Hydraulic Consulting Ltd.  "#!$#$!"The structural design and analysis of the underground detention tanks requires reference to several codes and guideline documents. The National Building Code of Canada (NBCC), and the BC Building Code (BCBC) were used to determine the design loads on the tank structure. The reinforced concrete design code (CSA A23.3) was used to design the tank structure. In order to meet LEED requirements, several documents on “green concrete design” were consulted. The following section provides detailed structural design information for the underground detention tanks.  !#'"When Portland cement is produced there is a significant amount of CO2 emitted from the calcinations of limestone. If the amount of CO2 emitted can be reduced a system is considered to be “more green”. To reduce the CO2 consumption, the amount of cement in a concrete mix must be reduced.  To ensure that the concrete used on this site is “green” and thus conforming to UBC’s goal to become more sustainable we propose to use supplementary cementing materials (SCM) to offset the cement used reducing the CO2.  All structural elements will use a 30 MPa mix design that incorporates 30% supplementary cementing materials, which reduces cement demand while increasing pozzolanic cementing efficiencies. The SCM recommended for this mix design is Fly Ash as it is readily available in Greater Vancouver at a competitive price. The concrete will be designed according to F-1 specifications for concrete exposed to freezing and thawing in a saturated condition, such as freshwater control structures. The material proportioning in the 30 MPa structural concrete mix is as follows: 30MPa Structural Mix • 210 kg Cement (300 kg minus SCM replacement) • 90 kg SCM (30% replacement) • 1100kg Coarse Aggregate • 750kg Fine Aggregate • 150 kg Water (0.5 w/c ratio)  - 18 - KREW Hydraulic Consulting Ltd. The mix proportions were based on the following general rules. Use 10kg of cement per 1 MPa of required strength where 20-30% can be replaced with a SCM (supplementary cementing material) like fly ash or blast furnace slag to reduce cement demand. The aggregate is approximately 80% of the total weight (with 60% of that being coarse aggregate,  and 40% being sand). The approximate density and water-to-cement ratio are 2300 kg/m3 and 0.5 respectively.  "#!$#$!(""The following subsection provides a summary of the design loading and analysis for the detention tank elements subjected to gravity loads. The gravity loads which are applied on the underground tanks are dead load (includes soil load), vehicle live load, and snow load. The magnitude of the load was determined in accordance with NBCC 2010. The following figure presents the gravity loads applied on the underground tanks.  Source: Kayle Rizzo (Feb 2016) Figure 5: Gravity Loading On Detention Tank  A structural model of the tanks was created using SAP 2000. The loads shown above were applied along the top slab of the detention tank. Based on the NBCC requirements it was determined that the governing loading case for the structure is: Governing Load Combination: 1.25 DL + 1.5 LL + 0.5 SL  - 19 - KREW Hydraulic Consulting Ltd. The structural model was analysed using the governing load combination. Based on the analysis, the maximum moment and shear force in the top slab are: Max Shear Force = 500 kN Max Bending Moment = 415 kNm The moment diagram for the top slab, produced by SAP 200, is shown in the figure below.  Source: Kayle Rizzo (Feb 2016) Figure 6: Detention Tank Top Slab Moment Diagram  Based on the results of the structural analysis the member size and required reinforcing for each element is determined. To determine the size of the tank walls the lateral earth pressures must be calculated.    "#!$#$!!#"The detention tanks have been designed in accordance with the National Building Code of Canada (NBCC), and consist of the following structural elements: strip footings, top and bottom slabs, slab bands, perimeter walls, and columns. The design calculations for the structural elements are provided in Appendix D.   ""The top slab is designed to transfer the vertical loads which are applied on the top surface of the tank to the columns and down into the footings. The top slab is 300mm thick and reinforced with 15M bars @ 400mm in both directions. The bottom slab is 200mm thick and reinforced with 15M bars @ 600mm in both directions. The top slab  - 20 - KREW Hydraulic Consulting Ltd. is thicker than the bottom slab as it is subjected to larger bending moments caused by the weight of the soil above. The bottom slab is fully supported by the soil below, reducing the required thickness and rebar spacing.  ""The slab bands are essentially wide beams which run along the column lines to effectively transfer the loads from the slab into the columns. The slab bands reduce stress concentrations in the slab and prevent punching shear. Furthermore, the use of the slab bands minimizes the overall thickness required for the top slab. The slab bands are 600mm wide x 400mm deep and are reinforced with 5 – 25M longitudinal bars.  $"The columns are distributed evenly throughout the tanks to support the top slab and prevent excessive deflections. The columns transfer the load from the slab bands directly down into the strip footings. The columns are 300mm in diameter and reinforced with 8 – 20M longitudinal bars and 10M spiral ties. 	 !#!&"The perimeter walls of the tanks are designed to resist both the gravity and lateral loads. The walls are designed to support the edges of the top slab as well as resist the lateral earth pressures which a maximum when the tank is empty. The walls resist both axial and bending forces simultaneously. The walls are 300mm thick and reinforced with 20M vertical bars at 200mm and 15M horizontal bars at 400mm.  "#!#"The strip footings are designed to spread the weight of the tank over a sufficient bearing area to prevent excessive settlements of the tank. Based on the bearing capacity of the soil, it was determined that 750mm wide strip footings placed along the column lines would be sufficient to minimize settlements.  - 21 - KREW Hydraulic Consulting Ltd. Detailed construction drawings for the detention tanks have been prepared and are included in Appendix A. Table 9 provides a summary of the dimensions required for each of the tank’s structural elements. The following figure is a 3D model of the detention tanks. Table 9: Structural Element Sizes & Dimensions Structural Element Size / Spacing  Strip Footings  750mm x 400mm Deep (Along Column & Wall Lines)  Top Slab  300mm Thick Reinforced Slab  Bottom Slab    200mm Thick Reinforced Slab on Grade  Slab Bands  600mm x 400mm Deep (Along Column Lines)  Perimeter Walls   300mm Thick Reinforced Slab  Columns  9 – 300mm dia. Columns (Evenly Spaced)   Source: Kayle Rizzo (Mar 2016) Figure 7: 3D Detention Tank Model   - 22 - KREW Hydraulic Consulting Ltd.  "#!&#!#!##In accordance to the B.C. Water Quality Guidelines and Metro Vancouver’s Municipal Water Use Guidelines, stormwater runoff should be treated in order to minimize the amount of sediment and improve the overall water quality before discharging to the environment. The introduction of stormwater treatment tanks, as shown in the figure below, can remove coarse sediment, oil and grease, and large particulates from stormwater. Instead of the traditional 3-chamber oil/grit separator shown below, Stormceptors have been implemented to treat the stormwater prior to discharge.  Source: Google Images (Feb 2016) Figure 8: Traditional 3-Chamber Oil/Grit Separator    "#!#!%!%&Stormceptor, provided by Imbrium Systems, will be installed upstream of the underground detention tanks and retention pond to provide treatment to stormwater runoff. The Stormceptor shown in Figure 9, provides more design flexibility compared to the traditional three-chamber systems, and is easier to access for maintenance and cleaning.   - 23 - KREW Hydraulic Consulting Ltd.   Source: Imbrium Systems (Feb 2016) Figure 9: Stormceptor STC   "#!#!")To size the Stormceptor model to meet the demands of each individual tank location, PCSWMM for Stormceptor, an advanced stormwater treatment sizing & design software, was used to determine the most appropriate Stormceptor treatment system for the site. Unit sizing is determined based on specific site conditions, including local rainfall data, particle size distribution, drainage area, imperviousness, runoff volume and inlet pipe sizing. Table 10 shows the input data used in the modelling software. Table 10: Input Data for PCSWMM for Stormceptor Parameter Tank 1 Tank 2 Tank 3 Pond Drainage Area 18 ha 16 ha 27 ha 43 ha Imperviousness 27% 27% 27% 27% Runoff Ratio 30% 30% 30% 30% Inlet Pipe Sizing 500 mm 500 mm 1000 mm 1000 mm  - 24 - KREW Hydraulic Consulting Ltd. The water quality objective is set to achieve a Total Suspended Solid (TSS) removal rate of 70%. The recommended Stormceptor model based on the PCSWMM program analysis is presented in Table 11 below. A detailed sizing report that includes projected performance calculations can be found in Appendix H. Table 11: Stormceptor Model Recommendation Provided by PCSWMM Site Drainage Area Provided % TSS Removal Recommended Model Tank 1 18 ha 71% STC 14000 Tank 2 16 ha 72% STC 14000 Tank 3 27 ha 73% Stormceptor MAX Pond 43 ha 72% Stormceptor MAX  Stormceptor STC 14000 Stormceptor STC 14000 is a Series Stormceptor designed to treat larger drainage areas. It consists of two adjacent Stormceptor models that function in parallel. This design eliminates the need for additional structures and piping to reduce installation costs. Table 12 shows the capacity of the STC 14000. Table 12: Stormceptor STC 14000 Capacity Model Total Storage Volume (L) Hydrocarbon Storage Capacity (L) Maximum Sediment Capacity (L) STC 14000 66410 11700 53890       - 25 - KREW Hydraulic Consulting Ltd. Stormceptor MAX Since the drainage area for Tank 3 exceeds the capacity of standard Stormceptor models, Stormceptor MAX is selected to provide treatment for the larger drainage areas. It is a modular stormwater treatment device that will require additional engineering and customization from Imbrium to meet the site’s condition. A schematic drawing of Stormceptor MAX is shown below.     Source: Imbrium Systems (Feb 2016) Figure 10: Stormceptor MAX  Shop drawings for Stormceptor STC 14000 and Stormceptor MAX are included in Appendix H.   - 26 - KREW Hydraulic Consulting Ltd.  !##"The retention pond is designed according to “Best Management Practices Guide for Stormwater – Metro Vancouver” which outlines the general design criteria for a dry retention basin. The pond will provide additional storage capacity for storms exceeding a 25-year flooding event up to a 100-year flooding event. The retention pond is designed to temporarily store stormwater and slowly release it at a controlled rate in order to minimize erosion at the outfall and in order to avoid flooding in downstream areas. A 3D schematic model of the retention pond is shown in the figure below.   Source: Tyler Mann (Nov 2015) Figure 11: Retention Pond & Filtration System Model      - 27 - KREW Hydraulic Consulting Ltd.  "#"The key design parameters of the the retention pond are as follows: • The pond will have a total volume of 6400 m3 at full capacity. • The pond bottom will have an optimal 2% slope towards the outlet in order to allow complete drainage during flooding events and prevent standing water conditions. • Non-woven geotextile material will be used to line the pond bottom in order to ensure stormwater does not infiltrate into the surrounding soil.  • Side slopes of the basin will be 3H:1V to ensure slope stability.  A schematic 2D drawing of a typical retention pond is shown below.  Source: Google Images (Mar 2016) Figure 12: 2D Retention Pond Schematic Drawing      - 28 - KREW Hydraulic Consulting Ltd.  !(The forebay is designed to settle out large sediment from the stormwater during intense rainfalls, in which the upstream Stormceptor MAX is bypassed to maintain sufficient drainage conditions. It will be placed at the inlet, upstream of the main pond, and will trap the majority of the coarse sediment in the stormwater before entering the main retention pond. The forebay volume will be equal to 10% of the total retention pond. The forebay will be separated from the dry basin area by barriers constructed of earth, and rip-rap.   !(%!&An emergency overflow will be constructed to allow storms exceeding a 100-year design event to pass through the pond with minimal destruction. The emergency overflow will be located on the downstream end of the retention pond to prevent stormwater from overtopping the pond embankment. The excess stormwater will be returned to the system’s mainline and discharged.  !#""#)#Pond berm embankments will be constructed on native consolidated soil, free of loose surface soil materials, roots, and other organic debris. The embankments will have side slopes of 3H: 1V to ensure slope stability. The exposed earth on the side slopes will be seeded with grasses to minimize soil erosion. 	 "&#!A low flow orifice will be installed at the outlet control structure to slowly allow the release of stormwater over a 24 to 72 hour period.  This slow controlled release of runoff will minimize erosion at the outfall. These structures are prone to becoming clogged with debris, therefore a guard will be installed to ensure the low flow orifice is protected.   - 29 - KREW Hydraulic Consulting Ltd.  #Proper upkeep and maintenance is important for the retention pond, as it ensures the pond’s continued functionality. Table 13 below outlines the various maintenance requirements after installation of the retention pond. Table 13: Summary of Maintenance Requirements Required Maintenance Frequency Debris Removal After large storm event Grass Cutting As needed Invasive Plant Control Semi annually Inspection – Outlet Control Structure Annually Repair Embankment, Side Slope, or Eroded Areas Annually, or as needed Sediment Removal – Forebay & Pond Bottom Every 5 years     - 30 - KREW Hydraulic Consulting Ltd.  "#!$#&!Due to the nature of the design, this project will not have one large centralized construction site, rather four smaller zones of construction activity spread throughout the South Campus. This presents unique challenges as all four locations are significantly space-constrained and often near sidewalks and accesses to major arterials. The three small underground tank work sites do not allow for much extra material and equipment storage, so any additional material will be stored at the larger retention pond site. With three underground tanks undergoing construction in tandem, coordinating concrete truck arrival times and optimizing equipment usage will be vital but left to the contractor’s discretion. The construction site layout including the total fenced area, tank location, and truck routes, for each of the four locations are presented below.    - 31 - KREW Hydraulic Consulting Ltd.  "#!$#"##The first tank construction site is located southeast of the Doug Mitchell Thunderbird Sports Centre. This location has relatively clear and easy access for concrete trucks with adequate room to maneuver using the Thunderbird Sports Centre loading bay. One of the challenges of this site is its proximity to the adjacent grass field which is frequently used by UBC sports teams. Proper fencing and safety offsets must be followed to prevent any conflict with competitive and recreational sports being played on the field. The site plan for Tank 1 is shown below in Figure 13.   Source: Adapted from Google Maps (Mar 2015) Figure 13: Tank 1 Site Plan     Tank Location       Truck Route    Fenced-In  Construction Site   - 32 - KREW Hydraulic Consulting Ltd.  "#!$#"##The construction site for tank #2 is located in the southeast corner of the RCMP parking lot. To facilitate the tank construction, 28 parking spots must be temporarily removed as they fall within the required fenced-in construction zone. This site is located off the main arterial of Wesbrook Mall and allows for concrete trucks to maneuver within the parking lot to access the site. This reduces traffic delays along Wesbrook Mall itself and eliminates the need for traffic control personnel at this location. The construction site plan for Tank 2 is shown below in Figure 14.   Source: Adapted from Google Maps (Mar 2015) Figure 14: Tank 2 Site Plan   Tank Location         Truck Route    Fenced-In  Construction Site - 33 - KREW Hydraulic Consulting Ltd.  "#!$#"##Tank 3 is located at the southeast corner of the roundabout at Wesbrook Mall and W 16th Avenue. This location will require removal of trees to facilitate room for the equipment to maneuver while constructing the tank. In addition, this location does not have an access or parking lot for trucks to park while unloading so the north side parking lane of Berton Avenue will be temporarily removed to allow for trucks to access the site. There is not adequate space for concrete trucks to turn around on Berton Avenue so traffic control personnel will be necessary to ensure traffic is stopped when trucks are backing off the site onto Wesbrook Mall. The construction site plan for Tank 3 is shown below in Figure 15.  Source: Adapted from Google Maps (Mar 2015) Figure 15: Tank 3 Site Plan   Tank Location       Truck Route     Fenced-In  Construction Site - 34 - KREW Hydraulic Consulting Ltd. 	 "#!$#"#!##The retention pond construction site is the largest of the four and is located at the northwest corner of SW Marine Drive and Wesbrook Mall. This location will house the project site office and any excess materials that cannot be stored on the other three sites. As on sites 1 and 2 an adjacent parking lot and loading bay will provide concrete trucks access to the site and allowing maneuvering to reduce traffic impact on Wesbrook Mall. The construction site plan for the retention pond is shown below in Figure 16.  Source: Adapted from Google Maps (Mar 2015) Figure 16: Retention Pond Site Plan   Tank Location       Truck Route   Fenced-In Construction Site     Site Office Location  - 35 - KREW Hydraulic Consulting Ltd.  !#"$The UBC Integrated Storm-Water Management Plan (ISMP) construction schedule will commence May 16, 2016 with a targeted completion date of October 28th, 2016. This timeframe is beneficial as most of the construction will occur while university classes are not in session, decreasing the impact on the public, and traffic delays. A full Gantt chart and task list can be found in Appendix E. In reference to the Gantt chart, separate tasks have been created summarizing individual tank construction. Although the schedule for each of these tasks looks similar, it should be noted that based on site characteristics, some of the sub-tasks duration may be longer. For example, material and equipment delivery, along with general construction activity will take longer at the Save-On Foods location, versus the RCMP location due to spatial constrictions and traffic. Thus, more time has been allocated to each sub task under “Save On Foods Tank”.  Each of the tanks will be constructed simultaneously, with the construction of the retention pond being the critical path, over 128 work-days, based on 5 day work-weeks. Hold points (inspections) have been included for the placement of the retention tanks, which will be conducted by the Project Manager. Having three separate crews will expedite construction, and further decrease the disruption to the surrounding community at UBC. For simplicity, a timeline has been included in the figure below, highlighting the key milestones during the project. Source: Jason Stewart (Mar 2016) Figure 17: UBC ISMP Project Milestones  - 36 - KREW Hydraulic Consulting Ltd. Regarding the timeline above, site mobilization will commence prior to any excavation. This will entail fencing the construction envelope, and establishing on-site storage for equipment. Mobilization will only occur after the site hazard assessment and field review have been completed by the Project Director. Subsequently, survey layout and grading will be performed at each site; this task will be ongoing throughout the project for as-built drawings and construction layout.  Excavations for retention tanks will follow, with trenching and pipe connections to the existing storm water system. Thereafter, formwork and rebar placement will be completed after excavations and specified levelling have been accomplished. At this stage, there will be an inspection on forms and rebar, as mentioned above. The retention pond will be constructed after the last tank has been completed, with an expected completion date of October 26th, 2016. This will give adequate time for project closeout documentation (as-built drawings, quality assurance documents) to be submitted to UBC Infrastructure for handover and commissioning.      - 37 - KREW Hydraulic Consulting Ltd.  #"#"##A Class 1 cost estimate has been completed for the final detailed design of the stormwater retention system. The expected cost of this project is $2.54 million with a contingency of 10% to account for variability in assumed unit prices. This contingency has been reduced from the previous 20%, used in the preliminary design stage, to reflect increased certainty in the design.  The cost estimate has been split into two sections. The first is the cost to complete the detailed design, obtain permits, project management, and all construction related activities. The second estimate is for the ongoing operations & maintenance of the proposed facilities.  As KREW Hydraulic Consulting is a relatively new and small company, we do not have enough relevant previous projects to estimate reasonable unit rates in-house. Instead, these costs were estimated from publicly available and respected sources like construction industry standard RS Means and Alberta Transportation’s Unit Price Averages report for 2014-2015. All unit prices found from these sources have been adjusted for interest and location accordingly. A summary of the cost for each major phase can be found below in Table 14 below. The full detailed cost estimates can be found in Appendix F. Table 14: Detailed Design Cost Estimate Summary Detailed Design Cost Estimate Summary Phase of Project Estimated Cost (Rounded) Detailed Design $205,000 Project Start-Up $15,500 Engineering & Testing $352,000 Site Mobilization & Survey $118,000 Foundations and Concrete $860,000 Retention Pond $395,500 Project Close-out & Handover $79,500 Contingency & Taxes $457,500 Grand Total $2,540,000    - 38 - KREW Hydraulic Consulting Ltd. There is expected to be ongoing operations and maintenance costs over the lifetime of the system. Most of the maintenance costs are related to the upkeep of the retention pond, to ensure the inlet and outlet pipes remain clear of debris. General upkeep tasks include: removal of leaves, grass cutting, and weed control.  As per manufacturer recommendation, the Stormceptor just upstream of the retention pond and tanks shall be calibrated every six months. In addition, the stormwater pipes attached to the tanks and pond need to be periodically checked for damage and repaired if necessary. It is expected these maintenance tasks will fall under the supervision of UBC’s Plant Operations branch, minimizing the cost of hiring a contractor. The estimated yearly operations and maintenance cost of this project will be $40,750. below provides an outline for the cost of monitoring and maintenance activities.  Table 15: Annual Estimated Operations and Maintenance Cost Item Interval Unit Cost per Unit Annual Cost Debris removal 3 times / year per visit $5000 $15,000 Grass cutting 5 times/year per visit $350 $1750 Invasive plant control 2 times/year per visit $350 $700 Stormceptor calibration        (x4 Stormceptors) 2 times/year per visit $300 $2400 Inspection 1 time/year per visit $100 $300 Additional inspection after large rainfall event 12 times/year per visit $50 $600 Repair embankment, side slope, or eroded areas 1 time/year per visit $5000 $5000 Pipe repairs 3 times/ year per visit $5000 $15,000 Total Cost    $40,750      - 39 - KREW Hydraulic Consulting Ltd.  $"!#"A major aspect of the design is to construct a large retention pond on the southern tip of campus. A crucial assumption that KREW Hydraulic Consulting made, was the availability of this land for stormwater use. UBC’s current land use plan for the south campus is quite conceptual and the area in which the retention pond is to be built is zoned for academic use. The retention pond will create several new constraints for future buildings that will be constructed in the areas surrounding the pond. Ideally, the retention pond would be designed in conjunction with the anticipated future buildings to ensure maximum integration of land use. In reference to Section 5.0, it is imperative that adequate borehole data is attained to model soil conditions in the proposed tank locations. If weak layers of soil are present underneath the bottom of the tank, ground improvement methods or complete site relocation may be necessary. Ground improvement methods can become very costly, especially during construction – work will be delayed until the soil has met engineered specifications. In the same way, site relocation would incur large cost over-runs as the tank would have to be redesigned based on unique conditions at a different site. Prior to any site activity, a pre-construction survey should be completed to record any existing flaws or damages to surrounding infrastructure. Furthermore, settlement monitoring should be implemented on a weekly basis at defined control points once construction has commenced. UBC’s south catchment is very large and with the continued development of the south campus, the strain on the stormwater management system will only increase. Although this increase in demand was incorporated in the design, KREW Hydraulic Consulting encourages UBC to employ new sustainable strategies like rain gardens, green roofs, and disconnected roof leaders to reduce the total impervious area. To have a truly successful and efficient stormwater management system, there must be both adequate infrastructure capacity and steps taken to reduce the overall demand.    - 40 - KREW Hydraulic Consulting Ltd.  !!" Alberta Transportation. (2015). Unit Price Averages Report. Edmonton, AB, Canada. Budhu, M. (2010). Soil mechanics and foundations (3rd ed.). Wiley. Hoboken, N.J. CFBA. (2002). Guidelines for Concrete Specifications. Canadian Farm Builders Association. Chillibeck, B., & Sterling, M. (2001). Urban Stormwater Guidlines and Best Management Practices for Protection of Fish and Fish Habitat. Retrieved from Fisheries and Oceans Canada: http://www.dfo-mpo.gc.ca/Library/277967.pdf City of Richmond. (2008). City of Richmond Storm Drainage Guidelines. Canada. Claremont Storm Management. (2015). Oil-Grit Separator. Retrieved from http://www.clermontstorm.net/oilgritseparator.pdf GeoAdvice Engineering Inc. (2013). Ubc Stormwater Model System Analysis, Detention Analysis And System Optimization. Port Moody, BC, Canada. Jr., E. R. (2011). How Does Pozzolanic Reaction Make Concrete "Green"?. Denver: World of Coal Ash Conference. Ministry of Water, Land and Air Protection. (2003). Environmental Management Act. Victoria: Queen's Printer. Parliament of Canada. (1985). Fisheries Act. Department of Fisheries and Oceans. Minister of Justice. Retrieved from http://laws-lois.justice.gc.ca/PDF/F-14.pdf Parliament of Canada. (1999). Canadian Environmental Protection Act. Minister of Justice. Portland Cement Association. (2005). Portland Cement Association. Retrieved 03 19, 2013, from http://www.cement.org/tech/faq_flexural.asp UBC Campus and Community Planning. (2010). Vancouver Campus Plan - Part 2: Details. ). University of British Columbia.  - 41 - KREW Hydraulic Consulting Ltd. UBC Campus and Community Planning. (2012). Land Use Plan for The University of British Columbia Point Grey Campus. University of British Columbia. UBC Campus and Community Planning. (2013, March). Development & Building Regulations. Retrieved from Campus + Community Planning: http://planning.ubc.ca/sites/planning.ubc.ca/files/documents/planning-services/policies-plans/UBCDevelopmentBldgRegs-Mar2013.pdf Urban Systems. (2011). UBC Integrated Water Management Plan (IWMP). Richmond, BC, Canada.    - 42 - KREW Hydraulic Consulting Ltd. '7!#!&"DESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION TANK 1 PLAN VIEW1/9RETENTION TANKEXISTING PIPEWESTBROOK MALLPLAN VIEW: RETENTION TANK 1NEW PIPE1616         - 43 - KREW Hydraulic Consulting Ltd.  DESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION TANK 2 PLAN VIEW2/9RCMP REAR PARKING LOTEXISTING PIPERCMP BUILDINGRETENTION PONDNEW PIPEPLAN VIEW: RETENTION TANK 21515 - 44 - KREW Hydraulic Consulting Ltd.  DESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION TANK 3 PLAN VIEW3/9WESTBROOK MALLEXISTING PIPERETENTION TANKNEW PIPEPLAN VIEW: RETENTION TANK 31919 - 45 - KREW Hydraulic Consulting Ltd.  QQOUT FLOWINFLOWSUPPORT COLUMNPLAN VIEW: RETENTION TANKELEVATION VIEW: RETENTION TANKAASECTION A-A - SUPPORTCOLUMN DETAILDETAIL - REINFORCEMENTDETAILSUPPORT COLUMNSTRIP FOOTING0.30.750.40,216,42,50,60,310M- SPIRAL TIES8-20M LONGITUDINAL BARS15M BARS AT 600mmEACH WAY15M BARS AT400mmEACH WAY15M BARS AT 400mm20M AT 200mmSLAB BANDSLAB BANDDESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION TANK 14/91616STORMCEPTER	 - 46 - KREW Hydraulic Consulting Ltd.  QQOUT FLOWINFLOWSUPPORT COLUMNPLAN VIEW: RETENTION TANKELEVATION VIEW: RETENTION TANKAASECTION A-A - SUPPORTCOLUMN DETAILDETAIL - REINFORCEMENTDETAILSUPPORT COLUMNSTRIP FOOTING0.30.750.40,216,42,50,6150,310M- SPIRAL TIES8-20M LONGITUDINAL BARS15M BARS AT 600mmEACH WAY15M BARS AT400mmEACH WAY15M BARS AT 400mm20M AT 200mmSLAB BANDSLAB BANDDESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION TANK 25/915STORMCEPTER		 - 47 - KREW Hydraulic Consulting Ltd.  QQOUT FLOWINFLOWSUPPORT COLUMNPLAN VIEW: RETENTION TANKELEVATION VIEW: RETENTION TANKAASECTION A-A - SUPPORTCOLUMN DETAILDETAIL - REINFORCEMENTDETAILSUPPORT COLUMNSTRIP FOOTING0.30.750.40,216,42,50,6190,310M- SPIRAL TIES8-20M LONGITUDINAL BARS15M BARS AT 600mmEACH WAY15M BARS AT400mmEACH WAY15M BARS AT 400mm20M AT 200mmSLAB BANDSLAB BANDDESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION TANK 36/919STORMCEPTER	 - 48 - KREW Hydraulic Consulting Ltd.  WESTBROOK MALLSW MARINE DRIVEFORESTED AREADESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION POND PLAN VIEW7/9	 - 49 - KREW Hydraulic Consulting Ltd.  13INLETOUTLETTOP OF BANKBOTTOM OF BANKFLOWS TO OUTFALLPLAN VIEW: RETENTION PONDELEVATION VIEW: RETENTION POND2%STORMCEPTERFOREBAYMAX WATER DEPTHGROUND LEVELOUTLETENERGENCY OVERFLOWINLETDESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNRETENTION POND8/9	 - 50 - KREW Hydraulic Consulting Ltd.  DESIGNED BY:DRAWN BY:TITLE:DRAWING NUMBER:KAYLE RIZZOTYLER MANNCONSTRUCTION DETAILS9/9NOTES:1. POND IS CONSTRUCTED BY SOILS ON SITE IF THEY MEETSTANDARDS TO BE USED AS ENGINEERED FILL2.ADDITIONAL SOIL INVESTIGATION MAY BE REQUIRED TODETERMINE PERMEABILITY AND ABSORPTION CAPACITY.3. POND IS TO BE CONSTRUCTED TO ENSURE INLET IS AT THEHIGHEST POINT AND OUTLET IS AT THE LOWEST.4.ROADS AND EXISTING PIPE ARE SHOWN IN APPROXIMATELOCATIONS AND MAY NEED TO BE ADJUSTED ON SITE5. TANKS ARE MADE FROM CAST IN PLACE REINFORCEDCONCRETETYPICAL SLAB BAND DETAILTYPICAL MAT LAYOUT WITH DROP PANNELSWALL CONSTRUCTION JOINT	 - 51 - KREW Hydraulic Consulting Ltd. '7(!"$#"Time of Concentration Calculation: Table 16: Average Time of Concentration At Southern Outfall Intensity (mm/hr) Outfall South (hrs) 0.5 9 1 7 2 6.75 3 4.5 4 3 6 4 Average TC 6   Rainfall Intensity Interpretation:   Source: Environment Canada (Nov 2015) Figure 18: Rainfall Intensity Chart Indicating Design Intensity  - 52 - KREW Hydraulic Consulting Ltd. Flood Volume Calculation:  Assuming only 5% of rainfall makes it into system the Q100 flood loss volume was calculated as follows:  /?C2<0?<D=6 m &>C6>B:CGl"A62l$2C49=6>C-2C:? /?C2<0?<D=6 m ==%A l%Al=Xl /?C2<0?<D=6 m =Y The Area of Catchment for Each Retention Unit: Table 17: Area of Catchment for Each Retention Unit   Drainage areas (m2) Percentage of total Tank Sizing (Q100) (m3) Southern Catchment 1,800,000 Tank 1  180,000 10% 500 Tank 2 160,000 9% 450 Tank 3 270,000 15% 750 Existing Tanks 760,000 42% 2100 Pond 427,000 24% 6400  Total Tank Storage 10,200   Source: Adapted from Google Maps (Nov 2015) Figure 19: Catchment Area of Each Retention Unit  - 53 - KREW Hydraulic Consulting Ltd. '7#"$#" Lateral Earth Pressures:      In the figure above, each stress prism has been identified to summarize the total lateral earth pressure. Layer 3 and 4 have different lateral pressure coefficients (Ka), depending on the friction angle of the soil in question. Stress prism 1 arises from the total overburden stress, of 1m embedment of the tank: Nqg m !  k  j  !  k  j  !  k   NqgW m ;+2 Stress prism 2 is the stress increase from a depth of 1m to a depth of 1.5m: NqgX m !  k  m  Stress prism 3 accounts for the total overburden stress, so summing 1 and 2: NqgY m NqgW j NqgX m ;+2 Stress prism 4 is the stress increase from depth of 1.5m to 3m depth: NqgZ m  !  k  m ;+2   - 54 - KREW Hydraulic Consulting Ltd. As mentioned above, we have assumed the water table is at ground level. The hydrostatic stress is shown in 5: Nqg[ m  !  m ;+2 Finally, the area of each stress block and each corresponding Ka are multiplied to find the total pressure per meter along each sidewall: +W m  ! !  m ;)= +X m  ! X !  m ;)= +Y m  !  !  m ;)= +Z m  !  !  !  m ;)= +[ m  ! X !  m ;)= QR m VUSPT     - 55 - KREW Hydraulic Consulting Ltd. Retention Tank Bearing Capacity Check:  Unit weight of water is assumed: 9.81 kN/m3 %G5A?BC2C:4#62A:>8+A6BBDA6 m = !  ;)=Y m ;+2 /2>;16:89C m  ! = ! = ! = j  !  ! = ! = !  ;8=Y /2>;16:89C m ;8 /2>;#62A:>8+A6BBDA6 m;8 !  =BX ! =  /2>;+A6BBDA6 m ;+2  Allowable bearing pressure on medium sand is 145 kPa. (Table 12.3 Budhu, 2010). With a factor of safety of 3 accounting for both the water table being present above the structure, and uncertainty in soil conditions:   ,\bbch\]b_ m m ;+2 ;+2 o ;+2     - 56 - KREW Hydraulic Consulting Ltd. '7"#!$#$!"$#"Appendix D provides detailed design calculations for the individual structural elements of the underground detention tanks. The structural design and analysis below is for the largest tank (i.e. governing design), and is based on the following design loads: Structural Gravity Loading: Dead Load = Soil Weight (20 kN/m3) + Pavement Weight (24 kN/m3) = 25 kPa Live Load = Vehicle Live Load = 2.4 kPa Snow Load = 2.0 kPa Based on the NBCC requirements it was determined that the governing loading case for the structure is: Governing Load Combination: 1.25 DL + 1.5 LL + 0.5 SL The gravity loads are applied to the tank along the top slab. The top slab is supported by the perimeter walls and the columns. The load that acts along the column lines: E` m  ;+2 j  ;+2 j  ;+2 m ;+2 E` m ;+2 ! = m ;)= A structural model was created for the tank and the design loads were applied. The structural model was analysed using the governing load combination. Based on the analysis, the maximum moment and shear force in the top slab are: Max Shear Force = 500 kN Max Bending Moment = 415 kNm The maximum shear force and bending moment are used to design the structural elements, based on the reinforced concrete design code (CSA A23.3).     - 57 - KREW Hydraulic Consulting Ltd. Flexural Member Design (Moment & Shear): The concrete design parameters (CSA A23.3): fy  400 MPa f'c 30 MPa φs 0.85 φc 0.65 α1 0.805 β1 0.895 The concrete design was done using an Excel spreadsheet by trial and error. The trial dimensions for the slab / slab band system are as follows: As 2500 mm2 h 700 mm d 650 mm bf 600 mm bt 600 mm     Determination of Neutral Axis: 2 m  Oe7i"eHWO^7^ 3 m !  ! X !  ! (+2 ! == m == Determination of Moment Resistance: (d m Oe7i"e 5 k2 m  !  ! X  k  m ;)= 300 mm 400 mm 600 mm  - 58 - KREW Hydraulic Consulting Ltd. (d m ;)= p ;)= m (`* ' Check Minimum Steel Yielding Requirements:  j 7i p4I5   p * ' /96A67?A6DB6 k (<?>8:CD5:>2<32AB Determine the shear reinforcement requirement and the shear resistance of the slab:  m  j 5g m j  ! == m  0^ m O^KI 7^ 3h5g m  !  !  !  !  !  m ;) The shear resistance of the concrete is less than the factored shear force, therefore transverse reinforcement (stirrups) are required:  	 m  ! g m ==  /AG(== 0e mOe"g7i5g  JB m ! == ! (@2 ! == ! == m ;) 0d m 0^ j 0e m ;) j ;) m ;) 0d m ;) p ;) m 0` * ' Check shear spacing requirements:   0d=2F m O^7^ 3h5g m  !  ! (+2 ! == ! == m ;) "g=:> m  7^3h.7i m   !  m == n == * '  - 59 - KREW Hydraulic Consulting Ltd. Column Design (Compression): Based on the analysis, the maximum column load = 1000 kN      Columns are 300 mm in diameter, 2000 mm tall, and reinforced with 8 – 20M longitudinal bars and 10M spirals. "a mL5X mL == X m ==X "ef m  k (32AB m  ==X m ==X Mf m"ef"a m  n =2F * ' Calculate the Axial Resistance of the column shown above: d m +^ j +e m HWO^7^ "a k "ef j Oe7i "ef  d m   (@2  k  j    m ;) +d m ;) p ;) m +` * ' As shown above, the factored resistance is significantly larger than the factored resistance. This is required to resist the bending moments introduced into the columns through the continuous connection at the column ends.  300 mm dia.  - 60 - KREW Hydraulic Consulting Ltd. '7#!#"$Table 18: Detailed List Of Project Tasks   - 61 - KREW Hydraulic Consulting Ltd.   - 62 - KREW Hydraulic Consulting Ltd.    /( *# 1. 0&,+ !$!! *+/%  !!! -%  #1(#% !# %#% # 8*$  %#%$, &%%  5*	 # %. % 4*$ &%#'% &%$%  %#% # 4*$  */%  %+#$$$$% 5* &&%1)!%&# 7*$ !!# ' $ !#($ ;*$  %#!# &#% 6($ -' ! :*$ !&! +0%  %&!1$$ 4*$	 #1#&$%$ ;*$ #%$% ## #%#$-"&!% :*$ &#'** &%1# 5:*$ "! '! ,0%  #	  ,0%  )'%% #"&#$  56*$ #1!!*%  %)$%$*$% 9*$ 	$%%##%$&!! #%/$ #,$%#&%$0 6*$ '1# 6*$  #( #1# #%$ 54*$	 %$!% ,!!# ' 4*$  &# %% $,$($1$&!! #%$ 6*$  &#% ! % 5* 	%1 &%% % $ 7*$ 1 '# 5* $!1&! 5* " ,.%  )'% $% #"&#$  54*$ #1!!*%  %)$%$*$% 9*$ 	$%%##%$&!! #%/$ #,$%#&%$0 6*$	 '1# 7*$  #( #1# #%$ <*$ %$!% ,!!# ' 4*$  &# %% $,$($1$&!! #%$ 6*$  &#% ! % 5* 	%1 &%% % $ 7*$ 1 '# 6*$ $!1&! 5* ! ,*%  )'% $% #"&#$  54*$	 #1!!*%  %)$%$*$% :*$ 	$%%##%$&!! #%/$ #,$%#&%$0 6*$ '1# 6*$  #( #1# #%$ =*$ %$!% ,!!# ' 4*$	  &# %% $,$($1$&!! #%$ 6*$	  &#% ! % 5*	 	%1 &%% % $ 6*$	 1 '# 6*$	  #%!%1#!% 7*$		 !# %#!#$1&! 5*	 !! -+% 	 )'%! #1$ !$% $! 5<*$	 #1!!*%  %)$%$*$% 59*$	 	% % # $#   7*$ &%% % % ##' <*$ 1 '# 7*$ $!1&! 6*$  '#1 $$  4*$		  "#  !"#          	   	                	     4 1+ 1) 1$ #- !0 /(-)&0&)#/0,+#1** .4+ !0&2#&)#/0,+#+ !0&2#1** .4 +1 ) /(1. 0&,+,+)40 .0,+)4&+&/%,+)430#.+ ) /(/30#.+ )&)#/0,+#.&0&! )-)&0.,$.#// +1 ).,$.#//.,'#!0.,'#!0!% 0# . - 63 - KREW Hydraulic Consulting Ltd. 	 Table 19: Detailed Cost Estimate Sheet !  #   ! !( / /'/""&2	"2&""=::&7;<;7=@/=::/'1&#(""&<<?&7;?C7=?/AA?/'2$ '(""&;=?&7;C?7<@/=<?/'3"!"(""&;B:&7<<=7>:/;>:/'//"# #'(3,<4@::&7;;;7@@/@::7<:?/;>:/3   (!/3'/0"&5+&(#$&!#"(&(#&;1)!$)!7;:/:::/3'/1"#"(&('/#)!"((#";1)!$)!7;/?::/3'/5&#(2#!(";1)!$)!7</:::/3'/7)!(& *"(#)!"(';1)!$)!7</:::7;?/?::/5/5'0(.&''''!"(;1)!$)!7</:::/5'7)  )(5,$"()&;1)!$)!7;?/:::/5'//$$&#* #'#$&+"';1)!$)!7<:/:::/5'/6#" !(& $&#)&!"(;1)!$)!7=:/:::/5'001$ "* #$;1)!$)!7<?/:::/5'03)#"') ("(2#(" ;1)!$)!7<::/:::/5'031	"'$(#"'"'(";1)!$)!7@:/:::7=?</:::./ 	$  - 64 - KREW Hydraulic Consulting Ltd. ./'0()$""5'"'?<>!;C0?:7;:/<;B./'6 &5&)'('?:::!<;:0::7?:/:::./'7&#(#'(2)$;1)!$)!7?/:::./'7&('(#&&#&!(& ';:::!<B0::7B/:::./'/.)&*- -#)(5&">>:&<::0::7BB/:::./'/1&#"(&# ;1)!$)!7;:/:::7;A;/<;B//! ) //'4,*((#&%)&!"'#"<?<@!=B0;:7<:/>@;//'6&"";::!<=0;?7</=;?//'0/;:::!!#"&($;::!;;;:0::7;;;/::://'03	"'(  '#&"/'(&)('@?!=::0::7;C/?:://'.0*  "5&"<::!<;<0::7</>:://'/6#&!+#&B><!<B:0::7@A/=@://'0.("'$(#"/$$&#* ;1)!$)!7</::://'0/(&$##("'>?!=<A;0::7;</;C?//'00#$ <?<0@!=<A;0::7@B/>??//'01#((#! ;@B0>!=<A;0::7>?/@=@//'02 "@:!=<A;0::7;@/<@://'03"&!(&  ';<:!=<A;0::7=</?<://'04# )!"'=0B<!=<A;0::7;/:=>//'10&'B><!<;=:0::7;:C/>@:04'20 1&($&(#&2;>:::<"(?::::0::7;::/:::04'20 1&($&(#&2(#&!$(#&,;"(A?:::0::7A?/::://'7  "5#*&B><!=;:0<;7B/?CA//'/4#"&($("5&$ !"(@=:!<;;:0::7@C/=:: - 65 - KREW Hydraulic Consulting Ltd. //'/0'$ ($("5&$ !"(@=:!<C:0::7?@/A:://'2"'$"BA:!<<>0::7<:/BB://'/3'(&(+#&'&!#* ;@B>!=;;0;<7;B/A<@7B?C/ACC04  04'1,*($#"&5' #$'@>;<!=B0;:7?;/C=A04'4&""#&" (1#)( (#""(#"<?:!<=0;?7?/ABB04'5	" ($3;:::!!4?:!;;;:0::7??/?::<@0B)( ($3;:::!!4?:!;;;:0::7??/?::04'/1#(,( <:<?!<=0A?7A/?C>04'/3'&;;=!=<<:0::7<>/B@:04'1."'$"<:::!<<>0::7>B/:::04'20 1&($&(#&2(#&!$(#&,;"(A?:::0::7A?/::://'/3'(&(+#&'&!#* @>;<!=;;0;<7A;/=:;7=C?/>B:./ ! )"./'./!#*""?<>!?0::7</@<:./'.0( "$?:::!<;:0::7?:/:::./'/3&('2) (&+"';1)!$)!7<?/:::./'/5)!(& *"(#)!"(';1)!$)!7</:::7AC/@<:)(#( 7</:AB/A?A#"(""-3;:F47<:A/BA@3?F47;:=/C=B3AF47;>?/?;= &+0%314%.61 - 66 - KREW Hydraulic Consulting Ltd. 		 Source: Kayle Rizzo (Nov 2015) Figure 20: Location Of Detention Tank 1   Source: Kayle Rizzo (Nov 2015) Figure 21: Location Of Detention Tank 2  - 67 - KREW Hydraulic Consulting Ltd.   Source: Kayle Rizzo (Nov 2015) Figure 22: Location Of Detention Tank 3   Source: Kayle Rizzo (Nov 2015) Figure 23: Location Of Retention Pond  - 68 - KREW Hydraulic Consulting Ltd. 				Appendix H provides detailed design calculations and product specifications for the individual Stormceptor treatment units provided by Imbrium Solutions Inc.   ######## 100 ##### ### ###STC 14000STANDARD MODEL####SHEETDATE: SCALE: CHECKED:DRAWN:PROJECT No.:OF THE DESIGN AND INFORMATION  SHOWN ON THIS DRAWING  IS PROVIDED  AS A SERVICE TO THE PROJECT OWNER,  ENGINEER AND CONTRACTOR  BY  IMBRIUM  SYSTEMS  ("IMBRIUM").   NEITHER THIS DRAWING,  NOR ANY PART THEREOF,  MAY BE USED, REPRODUCED  OR MODIFIED  IN ANY MANNER WITHOUT THE PRIOR WRITTEN  CONSENT  OFIMBRIUM.   FAILURE TO COMPLY IS DONE AT THE USER'S OWN RISK AND IMBRIUM  EXPRESSLY  DISCLAIMS  ANY LIABILITY  OR RESPONSIBILITY  FOR SUCH USE.  IF DISCREPANCIES  BETWEEN  THE SUPPLIED INFORMATION  UPON WHICH THE DRAWING  IS BASED AND ACTUAL  FIELD CONDITIONS  ARE ENCOUNTERED  AS SITE WORK PROGRESSES,THESE DISCREPANCIES MUST BE REPORTED TO IMBRIUM IMMEDIATELY FOR RE-EVALUATION OF THE DESIGN.  IMBRIUM ACCEPTS NO LIABILITY FOR DESIGNS BASED ON MISSING, INCOMPLETE OR INACCURATE INFORMATION SUPPLIED BY OTHERS .DATEREV # REVISION DESCRIPTION BYNUMBER  1     1USA 888-279-8826    CA 800-565-4801    INTL +1-416-960-9900		THE STORMCEPTOR SYSTEM IS PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENTS:United States Patent No. 5,753,115 • 5,849,181 • 6,068,765 • 6,371,690 • 7,582,216 • 7,666,303 | Australia Patent No. 693,164 • 707,133 • 729,096 • 779,401 • 289,647 • 2008,279,378 • 2008,288,900 |Canadian Patent No. 2,009,280 • 2,137,942 • 2,175,277 • 2,180,305 • 2,180,383 • 2,206,338 • 2,327,768 | Indonesian Patent No. 007058 | Japan Patent No. 3581233 • 9-11476 |Korea Patent No. 10-1451593 •  0519212 | Malaysia Patent No. 118987 | New Zealand Patent No. 314,646 • 583,583 • 583,008 | South African Patent No. 2010/00683 • 2010/01796 |			Project Information & LocationProject Name CIVL 446 Capstone Project Number 693City State/ Province British ColumbiaCountry Canada Date 3/29/2016 Designer Information EOR Information (optional)Name a a Name  Company UBC CompanyPhone # 123-123-1234 Phone #Email @hotmail.com EmailThe recommended Stormceptor Model(s) which achieve or exceed the user defined water quality objective for each site within the project are listed in the below Sizing Summary table.Site Name Tank 1Recommended Stormceptor Model STC 14000Target TSS Removal (%) 70.0TSS Removal (%) Provided 71PSD NJDEPRainfall Station VANCOUVER - KITSILANO HIThe recommended Stormceptor model achieves the water quality objectives based on the selected inputs, historical rainfall records and selected particle size distribution.Detailed Stormceptor Sizing Report – Tank 1Stormceptor Sizing SummaryStormceptor Model % TSS Removal Provided% Runoff Volume Captured ProvidedSTC 300 16 40STC 750 36 64STC 1000 48 64STC 1500 49 64STC 2000 53 82STC 3000 55 82STC 4000 60 93STC 5000 60 93STC 6000 63 97STC 9000 68 99STC 10000 67 99STC 14000 71 100Stormceptor MAX Custom CustomStormwater Treatment RecommendationStormceptor Detailed Sizing Report – Page 1 of 8Notes• Stormceptor performance estimates are based on simulations using PCSWMM for Stormceptor, which uses the EPA Rainfall and Runoff modules.• Design estimates listed are only representative of specific project requirements based on total suspended solids (TSS) removal defined by the selected PSD, and based on stable site conditions only, after construction is completed.• For submerged applications or sites specific to spill control, please contact your local Stormceptor representative for further design assistance.Stormceptor The Stormceptor oil and sediment separator is sized to treat stormwater runoff by removing pollutants through gravity separation and flotation. Stormceptor’s patented design generates positive TSS removal for each rainfall event, including large storms. Significant levels of pollutants such as heavy metals, free oils and nutrients are prevented from entering natural water resources and the re-suspension of previously captured sediment (scour) does not occur. Stormceptor provides a high level of TSS removal for small frequent storm events that represent the majority of annual rainfall volume and pollutant load. Positive treatment continues for large infrequent events, however, such events have little impact on the average annual TSS removal as they represent a small percentage of the total runoff volume and pollutant load. Design Methodology Stormceptor is sized using PCSWMM for Stormceptor, a continuous simulation model based on US EPA SWMM. The program calculates hydrology using local historical rainfall data and specified site parameters. With US EPA SWMM’s precision, every Stormceptor unit is designed to achieve a defined water quality objective. The TSS removal data presented follows US EPA guidelines to reduce the average annual TSS load. The Stormceptor’s unit process for TSS removal is settling. The settling model calculates TSS removal by analyzing: • Site parameters • Continuous historical rainfall data, including duration, distribution, peaks & inter-event dry periods • Particle size distribution, and associated settling velocities (Stokes Law, corrected for drag) • TSS load • Detention time of the systemHydrology AnalysisPCSWMM for Stormceptor calculates annual hydrology with the US EPA SWMM and local continuous historical rainfall data. Performance calculations of Stormceptor are based on the average annual removal of TSS for the selected site parameters. The Stormceptor is engineered to capture sediment particles by treating the required average annual runoff volume, ensuring positive removal efficiency is maintained during each rainfall event, and preventing negative removal efficiency (scour). Smaller recurring storms account for the majority of rainfall events and average annual runoff volume, as observed in the historical rainfall data analyses presented in this section.Rainfall StationState/Province British Columbia Total Number of Rainfall Events 5128Rainfall Station Name VANCOUVER - KITSILANO HI Total Rainfall (mm) 24905.7Station ID # 4201 Average Annual Rainfall (mm) 1245.3Coordinates 49°15'N, 123°9'W Total Evaporation (mm) 600.8Elevation (ft) Total Infiltration (mm) 18169.0Years of Rainfall Data 20 Total Rainfall that is Runoff 6135.9Stormceptor Detailed Sizing Report – Page 2 of 8Drainage AreaTotal Area (ha) 18Imperviousness % 27.0Water Quality ObjectiveTSS Removal (%) 70.0Runoff Volume Capture (%) 30.00Oil Spill Capture Volume (L)Peak Conveyed Flow Rate (L/s)Water Quality Flow Rate (L/s)Design DetailsStormceptor Inlet Invert Elev (m)Stormceptor Outlet Invert Elev (m)Stormceptor Rim Elev (m)Normal Water Level Elevation (m)Pipe Diameter (mm) 500Pipe Material CIP - cast ironMultiple Inlets (Y/N) NoGrate Inlet (Y/N) NoParticle Size Distribution (PSD)Removing the smallest fraction of particulates from runoff ensures the majority of pollutants, such as metals, hydrocarbons and nutrients are captured. The table below identifies the Particle Size Distribution (PSD) that was selected to define TSS removal for the Stormceptor design.NJDEPParticle Diameter(microns)Distribution % Specific Gravity2.0 5.0 2.655.0 5.0 2.658.0 10.0 2.6520.0 15.0 2.6550.0 10.0 2.6575.0 5.0 2.65100.0 10.0 2.65150.0 15.0 2.65250.0 15.0 2.65500.0 5.0 2.651000.0 5.0 2.65Up Stream StorageStorage (ha-m) Discharge (cms)0.000 0.000Up Stream Flow DiversionMax. Flow to Stormceptor (cms)Stormceptor Detailed Sizing Report – Page 3 of 8Site Name Tank 1Site DetailsDrainage AreaTotal Area (ha) 18Imperviousness % 27.0Infiltration ParametersHorton’s equation is used to estimate infiltrationMax. Infiltration Rate (mm/hr) 61.98Min. Infiltration Rate (mm/hr) 10.16Decay Rate (1/sec) 0.00055Regeneration Rate (1/sec) 0.01Surface CharacteristicsWidth (m) 849.00Slope % 2Impervious Depression Storage (mm) 0.508Pervious Depression Storage (mm) 5.08Impervious Manning’s n 0.015Pervious Manning’s n 0.25EvaporationDaily Evaporation Rate (mm/day) 2.54Dry Weather FlowDry Weather Flow (lps) 0Maintenance FrequencyMaintenance Frequency (months) > 12Winter MonthsWinter Infiltration 0TSS Loading ParametersTSS Loading FunctionBuildup/Wash-off ParametersTarget Event Mean Conc. (EMC) mg/L Exponential Buildup PowerExponential Washoff ExponentTSS Availability ParametersAvailability Constant AAvailability Factor BAvailability Exponent CMin. Particle Size Affected by Availability (micron)Stormceptor Detailed Sizing Report – Page 4 of 8Cumulative Runoff  Volume by Runoff RateRunoff Rate (L/s) Runoff Volume (m³) Volume Over (m³) Cumulative Runoff Volume (%)1 70.315 1034.782 6.44 232.969 872.116 21.19 442.61 662.055 40.116 661.199 443.817 59.825 843.946 260.636 76.436 956.122 149.146 86.549 1020.913 84.192 92.464 1059.22 45.799 95.981 1081.098 23.939 97.8100 1091.39 13.629 98.8121 1097.026 7.973 99.3144 1099.903 5.101 99.5169 1101.654 3.346 99.7196 1102.762 2.24 99.8225 1103.481 1.52 99.9256 1103.932 1.069 99.9289 1104.243 0.758 99.9Stormceptor Detailed Sizing Report – Page 5 of 8Stormceptor Detailed Sizing Report – Page 6 of 8Rainfall Event AnalysisRainfall Depth (mm)No. of Events Percentage of Total Events (%)Total Volume (mm) Percentage of Annual Volume (%)6.35 4012 78.2 6090 24.512.70 555 10.8 5038 20.219.05 275 5.4 4288 17.225.40 119 2.3 2641 10.631.75 63 1.2 1790 7.238.10 43 0.8 1499 6.044.45 16 0.3 664 2.750.80 10 0.2 475 1.957.15 15 0.3 806 3.263.50 5 0.1 296 1.269.85 3 0.1 196 0.876.20 3 0.1 219 0.982.55 3 0.1 240 1.088.90 1 0.0 86 0.395.25 2 0.0 182 0.7101.60 0 0.0 0 0.0107.95 1 0.0 104 0.4114.30 0 0.0 0 0.0120.65 1 0.0 120 0.5127.00 0 0.0 0 0.0133.35 0 0.0 0 0.0139.70 0 0.0 0 0.0146.05 0 0.0 0 0.0152.40 0 0.0 0 0.0158.75 0 0.0 0 0.0165.10 0 0.0 0 0.0171.45 1 0.0 170 0.7177.80 0 0.0 0 0.0184.15 0 0.0 0 0.0Stormceptor Detailed Sizing Report – Page 7 of 8For Stormceptor Specifications and Drawings Please Visit: http://www.imbriumsystems.com/technical-specificationsStormceptor Detailed Sizing Report – Page 8 of 8

Cite

Citation Scheme:

        

Citations by CSL (citeproc-js)

Usage Statistics

Share

Embed

Customize your widget with the following options, then copy and paste the code below into the HTML of your page to embed this item in your website.
                        
                            <div id="ubcOpenCollectionsWidgetDisplay">
                            <script id="ubcOpenCollectionsWidget"
                            src="{[{embed.src}]}"
                            data-item="{[{embed.item}]}"
                            data-collection="{[{embed.collection}]}"
                            data-metadata="{[{embed.showMetadata}]}"
                            data-width="{[{embed.width}]}"
                            data-media="{[{embed.selectedMedia}]}"
                            async >
                            </script>
                            </div>
                        
                    
IIIF logo Our image viewer uses the IIIF 2.0 standard. To load this item in other compatible viewers, use this url:
https://iiif.library.ubc.ca/presentation/dsp.18861.1-0343393/manifest

Comment

Related Items