Elevator drive systems energy consumption study report Chan, Benny ChunYin Apr 6, 2012

Your browser doesn't seem to have a PDF viewer, please download the PDF to view this item.

Item Metadata

Download

Media
18861-Chan_B_SEEDS_2012.pdf [ 964.21kB ]
Metadata
JSON: 18861-1.0108561.json
JSON-LD: 18861-1.0108561-ld.json
RDF/XML (Pretty): 18861-1.0108561-rdf.xml
RDF/JSON: 18861-1.0108561-rdf.json
Turtle: 18861-1.0108561-turtle.txt
N-Triples: 18861-1.0108561-rdf-ntriples.txt
Original Record: 18861-1.0108561-source.json
Full Text
18861-1.0108561-fulltext.txt
Citation
18861-1.0108561.ris

Full Text

UBC Social Ecological Economic Development Studies (SEEDS) Student Report Elevator Drive Systems Energy Consumption Study Report Benny ChunYin Chan  University of British Columbia EECE 492 April 6th, 2012 Disclaimer: “UBC SEEDS provides students with the opportunity to share the findings of their studies, as well as their opinions, conclusions and recommendations with the UBC community. The reader should bear in mind that this is a student project/report and is not an official document of UBC. Furthermore readers should bear in mind that these reports may not reflect the current status of activities at UBC. We urge you to contact the research persons mentioned in a report or the SEEDS Coordinator about the current status of the subject matter of a project/report”.Elevator Drive Systems  Energy Consumption Study Report  April 2012   0   2012     Elevator Drive Systems Energy Consumption Study Report     Benny CY Chan  UBC 1/1/2 01 2  Prepared for EECE 492   Benny ChunYin Chan  April 6th 2012 Elevator Drive Systems  Energy Consumption Study Report  April 2012   1  1 Table of Contents 1 Table of Contents ................................ ................................................................................................ .. 1  2 Acknowledgement ................................ ................................................................................................  2  3 Introduction and Purpose .....................................................................................................................  2  4 Methodology ................................ ................................................................................................ ......... 3  4.1 Data Measurement and Collection ...............................................................................................  4  4.2 Power Consumption Measurements ............................................................................................  5  4.3 Ambient Power Consumption ................................................................................................ ....... 5  4.4 Processing of Measurement Da ta ................................................................................................ . 6  5 Comparison and Analysis of Results ................................................................................................ ..... 9  5.1 UBC Gage Tower ................................ ...........................................................................................  9  5.1.1 UBC Gage Tower - Ambient ................................................................................................ .......... 9  5.1.2 UBC Gage Tower - Up Trip ................................................................................................ .......... 10  5.1.3 UBC Gage Tower - Down Trip ................................................................................................ ...... 11  5.2 Panarama Tower ................................ .........................................................................................  11  5.2.1 Panarama Tower - Ambient ................................................................................................ ........ 11  5.2.2 Panarama Tower - Trip Up ................................................................................................ .......... 11  5.2.3 Panarama Tower - Trip Down ................................................................................................ ..... 11  5.3 Metro Tower 1 ................................ ............................................................................................  12  5.3.1 Metro Tower 1 - Ambient ................................................................................................ ........... 12  5.3.2 Metro Tower 1 - Trip Up ................................................................................................ ............. 12  5.3.3 Metro Tower 1 - Trip Down ................................................................................................ ........ 12  6 Conclusion ................................ ................................................................................................ ........... 13  7 Discussion and Recommendation ................................................................................................ ....... 14  7.1 Discussion ................................ ................................................................................................ .... 14  7.2 Recommendation ................................ ........................................................................................  14  8 Appendix I: Processed Data ................................................................................................ ................ 15     Elevator Drive Systems  Energy Consumption Study Report  April 2012   2  2 Acknowledgement  This project is a study to investigate the power and energy consumption of different elevator drive systems. This project was initiated by UBC Plant Operations. Through the efforts of UBC SEEDS (Social Ecological Economic Development Studies) Program, this project became a collaboration of Vertech Elevator Services Inc. and UBC Electrical Engineering.  Michael D. Chadney from Vertech Elevator Services Inc. is a Professional Engineer specialized in Elevator Engineering Consulting business. Benny ChunYin Chan from UBC Electrical Engineering is a fourth year student specialized in Electrical Energy Systems option. This report is produced by Benny ChunYin Chan, and reviewed by Michael D. Chadney.   3 Introduction and Purpose In this elevator energy consumption study , the electrical energy and power consumptions of different elevator drive systems are measured.  Measurements were taken on elevator equipment shortly before they were upgraded with new control and drive systems. The measurements were taken before and after changes were made to the elevator in order to compare the relative power consumption of the old and new elevator drive systems.  The measurements taken allow us to compare each system and draw a quantitative conclusion for any potential energy saving of newer elevator drive systems.   Elevator Drive Systems  Energy Consumption Study Report  April 2012   3  Picture 5.2: New Drive System in Metro Tower 1, Burnaby.  4 Methodology  There are three (3) different case studies presented in this report. For each site, a power logger was used to measure the instantaneous voltage and current of the AC line the elevator is connected to. This report considers three (3) different case studies: 1. UBC Gage Tower – the equipment was upgraded to an AC Variable Frequency Drive with a Regenerative Drive add-on from a DC Variable Voltage system with a motor-generator set. 2. Panarama Tower – the equipment was upgraded with a new Permanent Magnet A C Gearless machine and an AC Variably Frequency Drive with a Regenerative Drive add-on from a geared machine and a DC Variable Voltage system with a motor-generator set.   3. Metro Tower 1 – the equipment was upgraded to an SCR Drive from a geared machine and a DC Variable Voltage system with a motor-generator set, while retaining the original DC Gearless machine. The elevator power consumption was measured while the equipment was idle and when the equipment was operating. This allowed us to calculate the power consumed while travelling the full height of the building, and allowed us to see what the ambient “standby” power consumption of each elevator system.   Picture 5.1: New Traction Machines in Panarama Tower, Burnaby. Elevator Drive Systems  Energy Consumption Study Report  April 2012   4  4.1 Data Measurement and Collection  In this study, Fluke 1735 Three Phase Power Logger is used to measure energy consumption of elevator drive systems. Fluke 1735 measures instantaneous voltage and current of each phase of the AC line the elevator drive system is connected to. It has a sampling rate of 10.24 kHz and averaging period of 0.5 second. It records average voltage and current of every 0.5 second to estimate power, energy, and harmonics distortion of voltage and current. When measures are performed, the Power Logger is connected to the AC line as shown below (the diagram shown below was extracted from the Fluke 1735 Manual):   When we first began the study, we connected the meter to one (1) elevator at the mainline disconnect and set up the meter to measure the power consumption over an extended period of time, up to three (3) weeks. When we downloaded the data for processing, we realized that we could not answer the fundamental question of “how much energy does an elevator require”. When we set the meter up for extended periods, we found that the sampling time of once every 30 seconds or one (1) minute could produce skewed results as the elevator ’s operation is not constant. The meter could sample to points in time when the elevator is idle, when in between sampling, the elevator was travelling between the intervals thus showing only the ambient power consumption. To fairly compare the energy consumption of two drive systems, the activities of the two systems must be the same. As a result, when a drive system is measured over a period of time without the details of Power Logger  Current Sensors Voltage  Clamps AC Lines  Figure 5.1: Power Logger Connection Diagram.  Elevator Drive Systems  Energy Consumption Study Report  April 2012   5  the elevator activities, the data obtained cannot be used to compare with another measurement of the same type. Therefore, no conclusion regarding the energy consumption is drawn from the measurements over a period of time. It was decided that we should focus on reducing the sampling frequency to the fastest sampling rate of 0.5 seconds to measure the voltage and current at all points of an elevator trip. With the data measured this way, we were able to calculate the power consumed for each elevator trip. Under controlled circumstances, we were able to calculate the power consumed for an elevator trip (for each direction of travel) and make direct comparisons for the power consumed before and after the elevators were retrofitted. 4.2 Power Consumption Measurements  Measurements are performed under different conditions to provide comparison of different drive systems. For comparison purposes and for convenience, the elevators in this report were measured when they had empty cars (no load) in both the UP and the DOWN direction. All the elevators in this case study are counterweighted traction elevators. Elevators are typically counterweighted such that the counterweight is 42% heavier than an empty car. Therefore, when an empty car is travelling in the down direction, it is lifting the heavier counterweight, which is similar to fully loaded elevator travelling in the UP direction.  Likewise, an empty car travelling UP is lowering the heavier counterweight. It is in this condition that an elevator can “regenerate” power by converting the energy of the weight travelling down into measurable electrical benefit with a regenerative style of drive. 4.3 Ambient Power Consumption The power measurements were taken before the elevator started and accelerated and was stopped after the elevator had reached its final destination. In the old configuration with Ward-Leonard drive systems, a field generator is used to control the amount of field current entering field coil of the DC machine; thus, controlling the speed of the DC machine. The operation of the field generator alone uses energy even when the car is not in motion. This characteristic does not exist in the new configurations as the VVVF drive for AC machine and PWM drive for DC machine does not use a field generator to regulate the field current. On Ward-Leonard systems, the generator will not always be running, but will turn on when there is demand on the system, and will turn off after a period of inactivity. The Elevator Drive Systems  Energy Consumption Study Report  April 2012   6  measurements were able to show the ambient power with the generator off, the spike when th e generator started, and the ambient power consumed when the generator remained running while the elevator was idle. 4.4 Processing of Measurement Data At various times in 2011 , measurements were performed on elevators at Gage Tower in UBC, Panarama Towers in Burnaby, and MetroTower1 in Burnaby as shown in table 1. The ambient power consumption in Watts and elevator cab operation energy consumption in Watt-hours are extracted from each of the measurements. Only consider the consumption and regeneration of active energy. Therefore, reactive energy is neglected in this study. Also, this study does not investigate for the effects of the drives modernization on power quality Since we cannot synchronize precisely the measurement and the drive system’s operation so that the measurement begins when the drive system starts driving the traction machine, the measurements are started before the elevator cab starts moving  and ends after the elevator cab stops moving by a few  seconds.  In addition, the drive systems consist of transformers and other electronics which consume energy even the elevator cab is not moving (i.e. in idle state) . This can be caused by the control system, the door operator and other resistive, eddy current, or hysteresis losses, which are parts of the ambient energy consumption of an elevator drive system. With the ambient energy consumption and the measurement not perfectly synchronize at the beginning and the end, the measurements consist of ambient energy consumption and elevator cab operation energy consumption of the drive system. To fairly compare the ambient power consumption and the elevator cab operation energy consumption in different elevator drive systems, these two data have to be extracted from each measurement. Notice that the ambient power consumptions are compared in Watts while the elevator cab operation energy consumptions are compared in Watt-hour. The graph below shows the active power consumed for one (1) elevator trip to show the extraction of ambient power consumption and elevator cab operation energy consumption from a measurement. Measurement #004 records the energy consumption when an elevator cab was driven down from the Elevator Drive Systems  Energy Consumption Study Report  April 2012   7  top to the bottom of terminal ending of the hoist way. From the data, power consumption starts increasing at t=9.5sec and stabilizes at t=44sec. Within this interval, the power consumptions are summed up to produce an elevator cab operation energy consumption of 92.33 Watt-hour. Additionally, the power consumption before t=9.5sec and after t=44sec are averaged to result in an ambient power consumption of  2257 .2 7 Watts.  Graph 1: Plot of Active Power Consumption against Time in Measurement #004   020 0040 0060 0080 0010 00012 00014 0000.0 2.5 5.0 7.510.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0Active Power (Watt) Time (Second)  Active Power vs. Time in Measurement #004 Elevator Drive Systems  Energy Consumption Study Report  April 2012   8  Table 1 shows all the ambient power consumption and elevator cab operation energy consumption from comparable measurements. Measurement ID Location Date Travel Direction Drive System Traction Machine Energy Consumed per Trip  (Watt-hour) Average Ambient Power Consumption (Watt) 002 UBC Gage Tower  May 6, 2011  Down  VVGFC  Geared DC  96.06  355.00  004 UBC Gage Tower  May 6, 2011  Down  VVGFC  Geared DC  92.33  2257.27  003 UBC Gage Tower  May 6, 2011  Up VVGFC  Geared DC  25.53  361.50  005 UBC Gage Tower  May 6, 2011  Up VVGFC  Geared DC  23.94  2213.04  011 UBC Gage Tower  May 16, 2011  Down  VVVF  Geared AC  92.38  438.46  013 UBC Gage Tower  May 1 6, 2011  Down  VVVF  Geared AC  93.01  452.57  015 UBC Gage Tower  May 16, 2011  Down  VVVF  Geared AC  92.56  446.72  010 UBC Gage Tower  May 16, 2011  Up VVVF  Geared AC  - 28.1 3  516.86  012 UBC Gage Tower  May 16, 2011  Up VVVF  Geared AC  - 27.8 6  434.67  014 UBC Gage Tower  May 16, 2011  Up VVVF  Geared AC  - 28.2 1  418.64  024 Panarama Tower  July 27, 2011  Down  VVGFC  Geared DC  98.60  1180.00  025 Panarama Tower  July 27, 2011  Up VVGFC  Geared DC  - 8.58  1150.30  031 Panarama Tower  October 5, 2011  Down  VVVF  Gearless AC  105.05  363.10  032 Panarama Tower  October 5, 2011  Down  VVVF  Gearless AC  105.01  348.46  033 Panarama Tower  October 5, 2011  Up VVVF  Gearless AC  - 33.0 2  355.38  034 Panarama Tower  October 5, 2011  Up VVVF  Gearless AC  - 33.0 7  353.33  106 Metrotower 1  November 15, 201 1  Down  SCR G earless DC 165.47  1759.35  108 Metrotower 1  November 15, 201 1  Down  SCR Gearless DC  158.48  1736.47  123 Metrotower 1  November 15, 201 1  Down  VVGFC  Gearless DC  267.71  6712.32  125 Metrotower 1  November 15, 201 1  Down  VVGFC  Gearless DC  268.20  6683.26  105 Metro tower 1  November 15, 201 1  Up SCR Gearless DC  21.75  1832.34  107 Metrotower 1  November 15, 201 1  Up SCR Gearless DC  13.30  1745.69  122 Metrotower 1  November 15, 201 1  Up VVGFC  Gearless DC  - 9.27  6688.99  124 Metrotower 1  November 15, 201 1  Up VVGFC  Gearless DC  - 17.1 1  6654.95  Table 1:  List of Measurements with Average Ambient Power Consumption and Energy Consumption.   Elevator Drive Systems  Energy Consumption Study Report  April 2012   9  5 Comparison and Analysis of Results From all the extracted data, key results are summarized in the table 2 as shown below. Observations at each measurement location are discussed below table 2. Location Power or Energy Consumption of Drive Systems Old Configuration New Configuration (with Regeneration Unit) Average Ambient Power Consumption (Watt) Average One Trip Up Energy Consumption (Watt-hour) Average One Trip Down Energy Consumption (Watt-hour) Average Ambient Power Consumption (Watt) Average One Trip Up  Energy Consumption (Watt-hour) Average One Trip Down  Energy Consumption (Watt-hour) UBC Gage Tower 358.25/  2235. 0  24. 5  94. 0  451.0  - 28. 0 *  92. 0  Panarama Tower 1165. 1  - 8.6 *  98. 6  355.1  - 33. 0 *  105.0  Metro Tower1 6684. 9  - 13. 2 *  268.0  1768. 5  17. 5  162.0  *Negative value represents a regeneration of active energy from the drive system to the AC line. Table 2: Comparison Summary of Measurement Results. 5.1 UBC Gage Tower  From the UBC Gage Tower measurements, there are a few observations: 5.1.1 UBC Gage Tower - Ambient In the old drive system, the field generator in the Ward-Leonard drive affects the ambient energy consumption. The field generator is kept operating for a certain period of time after the elevator finish a trip. The field generator is shut down after the elevator is not being called within that period of time.  In table 2, the two numbers shown as the ambient power consumption of the old drive system of UBC represents the ambient power consumptions when the field generator is on and off. When the field generator is not operating the ambient power consumption 358.2 5  watt, and when the field generator is operating without the elevator cab in motion, the power consumption is 2235 .0 Watt. In the new drive system , there is no field generator. So the ambient power consumption mainly depends on the efficiency of power transformer and the operation of the electronics of the drive system. Elevator Drive Systems  Energy Consumption Study Report  April 2012   10   Since there are two numbers from the old system for comparison, an estimation can help drawing a conclusion. In this estimation, we assume the field generator operate 8 hours a day and rest of the day (i.e. 16 hours) it is not running. We obtain an estimation as shown in table 3. Old Drive System (with field generator) New Drive System  (without field generator) Ambient Power (Watt)  Operation Time (Hour)  Resultant Ambient Energy  (Watt - hour)  Ambient Power (Watt)  Operation Time (Hour)  Resultant Ambient Energy  (Watt - hour)  3 58.25  16  23612 4 5 1  24  10824 2 2 3 5  8      Table 3: Estimation for Ambient Energy Consumption Comparison. From the estimation, the resultant ambient energy consumption of the old drive system is more than two times of the number of the new drive system. This shows a reduction in ambient energy consumption after retrofitting into a new drive system at UBC Gage Tower. 5.1.2 UBC Gage Tower - Up Trip In the old drive system, even without a regenerative unit, there is regeneration of energy when the elevator cab is braking at the end of a trip traveling up. (See measurement #005) However, the amount is not enough to cause a net regeneration of energy in any trip measured with the old drive. In other words, there are points of time when active power is being recovered by the old drive, but energy is always consumed within a trip with the old drive system. In the new drive system, with the aid of regenerative unit, energy is being recovered after the traction machine initiates the motion of the elevator cab and counterweight. At the end of a full trip up the hoist way, there is a net regeneration of energy from the drive system to the AC line. (See measurement 010) The energy recovered during the trip up by regenerative unit in the new drive system contributes to a significant reduction in energy consumption in a trip up. Elevator Drive Systems  Energy Consumption Study Report  April 2012   11   5.1.3 UBC Gage Tower - Down Trip With the old drive, the average energy consumption for an empty elevator cab travelling a full trip down the hoist way is 94 Watt-hour. With the new drive, the average energy consumption for an empty elevator cab travelling a full trip down the hoist way is 92 Watt-hour. The results show a minor reduction of average energy consumption for an empty elevator cab travelling a full trip down. 5.2 Panarama Tower From the Panarama measurements, there are a few observations: 5.2.1 Panarama Tower - Ambient With the old drive system, there are only measurements performed when the field generator is running. The ambient power consumption is 1165 .1 Watt. With the new drive system, the ambient power consumption is 355.1 Watt. The results show a significant reduction of ambient power consumption with the new drive systems. 5.2.2 Panarama Tower - Trip Up With the old drive system, unlike the case in UBC Gage Tower, the measurement for a full trip up shows a net regeneration of active energy of 8.6 Watt-hour. (See measurement #025) With the new drive system, the average net regeneration of energy is 33.0 Watt-hour per full trip up. In the new drive system, the regenerative unit allows more efficient recovery of energy to the AC line than the Ward-Leonard system in the old drive system. Therefore, it results in a regeneration of a larger quantity of active energy. 5.2.3 Panarama Tower - Trip Down With old drive system, the average energy consumption for a full trip down is 98.6 Watt-hour. With new drive system, the average energy consumption for a full trip down 105.0 Watt-hour. At Panarama Towers, we were not expecting to see the power consumption one trip in the down direction to consume more power with the new system than the old system.   Elevator Drive Systems  Energy Consumption Study Report  April 2012   12   The equipment was retrofitted with a more efficient gearless machine with a new AC Variable Frequency drive.   The only plausible explanation is that the new equipment was running at contract speed of 350 fpm, whereas the old system might have been running at a slower speed.  It is quite common for older DC Variable voltage systems to degrade in speed without vigilant maintenance or the speeds were purposely slowed down for reliability reasons. 5.3 Metro Tower 1 From the Metro Tower 1 measurements, there are a few observations: 5.3.1 Metro Tower 1 - Ambient With the old drive system, there are only measurements performed when the field generator is running. The ambient power consumption is 6684 .9 Watt. With the new drive system, the ambient power consumption is 1768 .5 Watt. The results show a significant reduction of ambient power consumption with the new drive systems. 5.3.2 Metro Tower 1 - Trip Up With old drive system, there is a net regeneration of energy of 13.2 Watt-hour. With new drive system, there is no regeneration of energy. Instead, the new drive system consumes 17.5 Watt-hour for a full trip up. There is no clear explanation why the elevator system would consume energy when traveling up when the regenerative drive system. 5.3.3 Metro Tower 1 - Trip Down With the old drive system, the average energy consumption for an empty elevator cab travelling a full trip down the hoist way is 268.0 Watt-hour. With the new drive system, the average energy consumption for an empty elevator cab travelling a full trip down the hoist way is 162.0 Watt-hour. The results show a significant reduction of average energy consumption for an empty elevator cab travelling a full trip down.  Elevator Drive Systems  Energy Consumption Study Report  April 2012   13   6 Conclusion Considering all the key results obtained from 3 case studies, we evaluate the percentage change on the ambient power, up trip and down trip energy consumption to aid drawing conclusion from results. Location Percentage Changes on Power or Energy Consumption of Elevator Systems after Retrofitting Average Ambient Power Consumption  (Wa tt) Average One Trip Up Energy Consumption  (Watt - hour)  Average One Trip Down Energy Consumption  (Watt - hour)  UBC Gage Tower - 54% *  - 214% *  - 2% *  Panarama Tower - 70% *  - 284% *  6%  MetroTower1 - 74% *  233%  - 40% *  *Negative value represents a decrease of new value comparing to original value. Table 4: Percentage Changes of Power or Energy Consumption of Elevator Systems after Retrofitting. From table 4, it shows that with the new drive systems, there are substantial energy savings in ambient power consumption when comparing to the old drive systems in all case studies. However, for elevator trips in up direction, only the new drive systems at UBC Gage Tower and Panarama Tower provide energy saving in form of increases in regeneration of active energy. Exception appears at Metro Tower 1 where the energy consumed for a trip in up direction increases after changing into the new drive system. In terms of trips in down direction, no significant differences were observed in the UBC Gage Tower and Panarama Tower cases. Nonetheless, a significant energy saving happens in the Metro Tower 1 case. In conclusion, the AC Variable Frequency Drive with an addition of regenerative drive add-on provides more efficient regeneration as is demonstrated at the UBC Gage Tower . At Panarama, the gearless AC traction machine driven by an AC Variable Frequency Drive provides greater regeneration capability than the original geared DC traction machine and DC Variable voltage system.    Elevator Drive Systems  Energy Consumption Study Report  April 2012   14   7 Discussion and Recommendation 7.1 Discussion Since one of the purposes of this study is to recommend potential policy changes building construction and operation at UBC. The brief estimation below could help policy makers gaining some insight. According to UBC Gage Tower Measurements, a round trip of the elevator cab can save 50 Watt-hour. Assuming the elevator cab travels 500 trips per day, it saves 25 kilowatt-hour per day. If we extend this number to a 365 -day year, 9125 kilowatt-hour of energy can be saved, which is equivalent to a $638 .75 saving per year based on the electricity price of $0.07 per kilowatt-hour in British Columbia. If we c onsider an add-on regenerative unit for an elevator drive system is $5000 , the payback period is almost 8 years .  Note that in this brief estimation, maintenance costs, additional installation and commissioning costs are not accounted. On the other hand, there are associated advantages not accounted for. For example, installation of regenerative drive systems may help obtaining certification in LEED or other building rating system. In addition, BC power smart program may extend the program to elevator equipment so that owner would receive incentive for the regenerative unit installation. 7.2 Recommendation This Elevator Drive Systems Energy Consumption study has a narrow scope focusing only on the net active power or energy consumed by the elevator systems. However, there are still other significant electrical aspects of an elevator drive system that can be investigated.  Since power quality is a treading topic in Power Engineering industry, an interesting aspect would be the effect on reactive power generation of elevator system with different elevator drive systems. There is a potential for power electronics elevator drive systems to reduce total harmonic distortion on voltage and current AC line is isolated by the rectifying circuitry. This potential advantage could bring monetary saving to building ownership as it could reduce the installation of power factor correction equipment in building.   Elevator Drive Systems  Energy Consumption Study Report  April 2012   15   8 Appendix I: Processed Data Due to the size and format of the Processed Data, it cannot be attached within this report. Please contact the SEEDS office should you wish to request the processed data for reference.    

Cite

Citation Scheme:

        

Citations by CSL (citeproc-js)

Usage Statistics

Share

Embed

Customize your widget with the following options, then copy and paste the code below into the HTML of your page to embed this item in your website.
                        
                            <div id="ubcOpenCollectionsWidgetDisplay">
                            <script id="ubcOpenCollectionsWidget"
                            src="{[{embed.src}]}"
                            data-item="{[{embed.item}]}"
                            data-collection="{[{embed.collection}]}"
                            data-metadata="{[{embed.showMetadata}]}"
                            data-width="{[{embed.width}]}"
                            async >
                            </script>
                            </div>
                        
                    
IIIF logo Our image viewer uses the IIIF 2.0 standard. To load this item in other compatible viewers, use this url:
http://iiif.library.ubc.ca/presentation/dsp.18861.1-0108561/manifest

Comment

Related Items