 Investigation of Repeatability of Sol-Gel Iridium Oxide pH Sensor on Flexible Substrate  Wen-Ding Huang, Lun-Chen Hsu, Jianqun Wang, Thermpon Ativanichayaphong, Sanchali Deb, Mu Chiao* and J.C. Chiao  Department of Electrical Engineering, University of Texas at Arlington, TX, USA *Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, Canada  ABSTRACT In this paper, we presented the fabrication process of miniature pH sensor arrays on flexible polymer substrates. The repeatability of the sensors based on sol-gel fabrication processes was investigated. The sensor repeatability was characterized with linearity, decay time, environmental parameter control and potential stability. Similar linear responses were found in different batches of sensor arrays. Near super- Nernstian responses were measured on each sensor with slope ranges from –71.6 to –110 mV/pH within a pH range between 2 and 12. The response times were compared in different batches. Six to twenty five seconds of average decay time were shown in each sample repeatedly. Three sensors showed the close potential response in different volumes of pH buffer solution. The sensor showed good stability in each step of the titration process between pH values of 1.8 and 11.9. The peak and saturated potential values presented high correlation with pH values with minor noises. The results showed good sensitivity, stability and repeatability using the sol-gel processes for iridium-oxide pH sensors on flexible substrates. Key words: miniature pH sensor, sol-gel process, linearity, decay time, environmental parameter control, potential stability INTRODUCTION Although the glass membrane pH electrodes have been used in wide range of applications because of the good sensitivity, selectivity, stability and long lifetime [1], the fragility and physical size features of glass electrodes still restrict the applications on in vivo biomedical, clinical and food monitoring. To target at those applications, the different kinds of miniature pH sensor such as ion-sensitive field-effect transistor (iSFET) pH sensors [2,3], optical fiber pH sensors [4,5], hydrogel film pH sensors [6] and solid-sate pH sensors [7,8] were investigated and demonstrated. However, most of those sensors were still built on rigid substrate such as silicon wafer or glass slide. The non-deformable pH sensors cannot be used for certain in vivo environment such as the neuronal implants [9,10]. Therefore, the polymer-based substrate [11] was chose and applied on the fabrication for the next generation pH sensor.  In our previous paper [12], we presented the use of sol-gel technique for the preparation of iridium oxide (IrOx) pH sensing film on flexible Kapton substrate. The solid state IrOx film was formed by sol-gel technique, dip-coating [1,13], and thermal oxidation [14] processes.  Micro- and Nanotechnology: Materials, Processes, Packaging, and Systems IV edited by Jung-Chih Chiao, Alex J. Hariz, David V. Thiel, Changyi Yang, Proc. of SPIE Vol. 7269, 726916 · © 2008 SPIE · CCC code: 0277-786X/08/$18 · doi: 10.1117/12.810675 Proc. of SPIE Vol. 7269  726916-1 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms KaptonAu Cr polymer (a) (d) Lift-Off IrOx pI.sioc (b) (e) AgCI Electroplating I I I (C) (f) Ag Crfl}13    In this paper, we presented the continuation of our previous work [12]. We demonstrated the repeatability, reproducibility, and stability of our pH sensor fabrication by the tests of linearity, time response, different volume, and step potential responses. The parameters including the metal thickness, sol-gel agent ratio, annealing temperature, and time of electro-plating on different fabrication batches were fixed in order to examine the repeatability and reproducibility of the fabrication process of our pH electrodes. Large- and small-volume tests demonstrated the stability of pH sensor performing in different environment condition.  The present paper showed the robust performance of our flexible pH sensor made by the simple IrOx sol- gel and AgCl electroplating methodology.  SENSOR FABRICATION  The pH sensor structures were formed on a flexible Kapton polyimide substrate. All metal layers were deposited by electron-beam evaporation. Photolithography and lift-off processes were applied in the fabrication procedures. Anodic Electrode Fabrication Procedure Metal deposition:  A layer of 70-Å thick Cr was deposited as an adhesion layer of the 1000-Å thick Au layer as show in Fig.1 (a).  Figure 1 Fabrication processes: (a) Cr and Au deposition, (b) IrCl4 sol-gel process after SU-8 deposition as the sacrificial layer, (c) lift-off process result, (d) Cr, Pt and Ag deposition with S1813 as the sacrificial layer, (e) lift-off process result, and (f) AgCl electroplating. Sacrificial layer: A 100 µm thick SU-8-100 photoresist layer was coated as shown Fig. 1(b) to be a sacrificial layer for IrOx sol-gel process. The SU-8 layer defined the sensing area on top of the Au layer. Proc. of SPIE Vol. 7269  726916-2 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms Power Source   IrOx sol-gel process: The sol-gel coating agent was based on the recipe described in [12,14]. The solution was stirred continuously for at least two hours with a magnetic rod. A thin layer on the flexible substrate was formed by dip coating at a 2 cm/min withdraw rate by hand holding. Thermal treatment: The sample was baked at 120°C for 15 minutes on a hot plate right after the dip coating process, and SU-8 layer was stripped off after baking. The sample was treated in an oven with a heating profile described in [12]. The surface needed to be treated at a temperature between 300°C and 350°C [15] to obtain an amorphous iridium oxide thin film.  Cathode Electrode Fabrication Procedure Metal deposition: 70-Å thick Cr was deposited, followed by a 60-Å thick layer of Pt as an adhesion layer for the Ag layer. A 3000-Å thick Ag layer was deposited using the electro-plating process on top of the Pt layer as shown in Fig.1 (d).           AgCl electro-plating: Electrochemical anodization process was used to obtain the silver chloride (AgCl) reference electrode same as the description in [12]. A brown silver chloride (AgCl) layer was formed on the silver surface. The electrodes were saturated in potassium chloride (KCl) [12,16]. Fig. 2 shows the electroplating setup for the AgCl reference electrodes. PDMS Enclosure PDMS polymer was made in a 10:1 ratio by weight of SYLGARD 184 and curing agent [17]. The mix was cured on a 70°C hot plate for 24 hours. The 0.2-cm thick PDMS layer was then bonded on the sensor surface with a well of 0.1 cm3 volume to confine pH buffer solution on the pH electrodes for measurements shown in Fig. 3 and Fig. 4 (b).   Figure 2 Electroplating setup for the AgCl reference electrodes. Figure 3 The PDMS polymer enclosure around the flexible pH sensor. Proc. of SPIE Vol. 7269  726916-3 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms Acid or alkalin& - dripping 4 . . . . -, AgCI Referen E!ectrodn RS-232 NI-DAQ 6008 Magnetic Stirring Acid or alkaline -4+,IrOx drippingWorkrg Edrade Hanna pH meter probe   THEORY The iridium oxide (IrOx) and silver chloride (AgCl) were used as sensing and reference electrodes, respectively. A pH-dependent redox equilibrium of two materials generated potential difference when pH was changed. There are three possible mechanisms on pH-dependent redox equilibriums between two oxidation states of IrOx. The pH potential sensitivity will be –59.16 mV/pH regarded as the Nernstian potential response [18-20].     MEASUREMENTS In this paper, we aimed to demonstrate the repeatability of our pH sensors fabricated in different batches. Fig.4 (a) shows the measurement setup for our flexible pH sensors. An NI-DAQ 6008 USB card with a LabVIEW program was used for analog potential recording. A commercial Hanna pH meter was used to verify the pH values of solutions. The contact pads of the pH sensor were coated by silver epoxy in order to have good conductivity for the connection between the sensor and the DAQ card. A thin layer of PDMS was coated on top of the silver epoxy as shown in Fig. 3 for isolation when pH sensor was immersed in the test solution.           Figure 4 The pH titration and measurement setups for (a) large and (b) small volumes of solution. pHEpH F RTEE o 16.59303.20 −=−= OHIreHOIr 232 3266 +↔++ −+ OHIreHIrO 22 244 +↔++ −+ OHOIreHIrO 2322 222 +↔++ −+ [1] [2] [3] [4] Proc. of SPIE Vol. 7269  726916-4 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms 05 04 03 0.2 01 -0 1 -02 A c Batch#1 p -0.1 lx + 0.135 -El- -Batch2 y -0.011th + 0.3144 A Batch#3 y=-0.0817x- 0.4875 0 4 6 8 pH 10 12 14   Titration test: The sensor was immersed in acid or alkaline based diluted solution stirred with a magnetic rod in the beaker. We used hydrochloric acid for acidic titration tests. NH3 and KOH were used for alkaline titration tests. The Hanna pH meter was placed in the solution and connected to its signal processing card. Both the potential from our sensor and the pH level from the Hanna pH meter were recorded in a computer simultaneously. Small volume test: The pH 2, 4, 6, 10 and 12 buffer solutions were dropped into the 0.1 ml well individually to test the sensor performance. The sensor was rinsed by DI water between each test. Large volume test: The sensor was immersed in 450 ml of pH 2, 4, 6, 10 and 12 buffer solutions individually in the beaker. The sensor was rinsed by DI water between each test.  RESULTS AND DISCUSSION Linearity Performance The reproducibility and repeatability of our fabrication process can be obtained by measuring three electrodes from different batches of identical fabrication process. Three linear potential responses of the three IrOx pH sensors were confirmed by pH titration tests. KOH was dripped into diluted HCl based solution for titration. Shown in Fig. 5, the pH sensors from three different fabrication batches demonstrated near linear super-Nernstian responses [20] with similar sensitivities of –71.6 mV/pH, –81.7 mV/pH and –110 mV/pH from pH=2 to pH=12 at 25°C. The variances of these three linear responses were 0.032, 0.018, and 0.02, respectively. These three sensors all performed better than the –59.16 mV/pH super-Nernstian’s sensitivity [18]. These sensitivity responses demonstrated good reproducibility in our fabrication process. The 10 to 30 mV of sensitivity deviations between sensors may be due to different oxidation state as described in [22,23].            Figure 5 Linear potential response for pH sensors from three batches. The tested pH ranges from 2 to 12.  Proc. of SPIE Vol. 7269  726916-5 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms 04 0 025 2 02 0 015 0.1 005 12 s.c 40 50 60 Time sec)() - Btth6l 1*12,2-84 - tch#2 pH2.3.7,7 0tci!3 pHl8-6.5 0.45 0,4 0.35 0.3 0 25 2 02 0.15 0I 0.05 -005 I 2. 25sec_ 'BatchSI, pll5.6-2.l - B.4chS2, p1-46 5-3.0 6tch#3, p4-15 6-2.0 22 t.ct 10 20 30 so70 100 50 60 Time ec I0 20 30 40 70 80 90 100 110 (b)    Response Time Performance Titration tests were performed to investigate the response time of our pH sensors. A rapid step change in pH level was represented by quickly adding a certain amount of HCl solution into alkaline-based solution or adding KOH solution into acidic solution. The response time is defined as the time required to reach 90% of the equilibrium value [21]. Fig. 6 shows the results of the pH sensors from three different fabrication batches with the transition steps of pH changing from pH=1.8 to pH=8.4 and from pH=5.6 to pH=2.0. The response times ranged from about 6 to 25 seconds, which also included and depended on the different mixing time of the dripped liquid with the base solution during titration processes. The localized mixing dynamics of liquid is difficult to control, however. These three sensors all showed similar and reasonable time responses during the titration, both from the acid to alkaline transition and alkaline to acid transition. This result not only presented good sensor reversibility, but also good reproducibility and repeatability.         Figure 6 Response times of our pH sensors from (a) pH=1.8 to pH=8, and (b) pH=5.6 to pH=2. Environment Parameters Fig. 7 demonstrates the potential responses with two different volumes of pH buffer solutions for the pH sensors from three different fabrication batches. 0.1 and 450 ml pH buffer solutions were used as the small and large volumes. Three batches of the pH sensors showed close potential responses in the small volume tests of pH= 2, 4, 6, 10 and 12 buffer solution. The 3rd batch pH sensor was tested in the large volume pH buffer solutions. Both in small and large volume tests, the pH sensors showed similar linear responses and clear identification of different pH levels. In the experiment, the large volume of buffer solution produced higher potentials than the small volume buffer solution did at the same pH levels. This may be due to much more hydrogen ions in the large volume of liquid than in the small volume. With the mechanism of our pH sensor, the sensing potential depends on the pH value, which is the log value of the activity of the ion numbers. In this ion-selective pH sensor, it responds to the potential created or released Proc. of SPIE Vol. 7269  726916-6 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms pH 0.3 0.25 0.2 0.15 0.1 Ct = - 0.05 0 0 -0.05 -0.1 0.1 o * + * 0 + * * + >< o Small Volume, Batch#1 Small Volume, Batch#2 Small Volume, Batch#3 Large Volume, Batch#3 0 * 4 6 8 10 12 0.4 0.35 0.3 0.25 0 0.20 0.15 0 0.0 0 a -0.05 -0 -0.15 0.2 pH Electrode #1 - Electrode #2 IS 50 100 150 200 250 300 350 400 450 so°O Tine(sec) 0 10 0 = E0 0) -D 05= a   by the active ions in the solution. Therefore, when the ion source is low, the potential will not reach the same level as the solution with higher ion strength does. The ion reduction also causes the result of slow response time resulting inaccurate pH measurements [24]. Potential Step Responses Fig. 8 shows potential responses of two IrOx sensors to pH changes in a series of five different pH levels. The diluted HCl-based solution was titrated by KOH dripping from pH=1.8 to pH=11.9. Two sensing potentials responded to the pH level changes quickly when the titration started. This experiment demonstrated the dynamic testing of sensors from two different fabrication batches. The result showed that the response transients of two electrodes were almost identical with the titration steps. The deviation of potentials may be due to the oxide states as described in [23]. The higher potential responds to higher valence oxide and vice versa. The oxidation state is determined by the composition of IrOx film that can vary the potential shift at the same level of pH [23]. This experiment showed good stability of our sensors, and good reproducibility of the sol-gel fabrication processes.            CONCLUSIONS  This paper presented the repeatability, reproducibility, and stability of an IrOx pH sensor fabricated on a flexible substrate. The sol-gel process was repeated in the different batches of fabrication process. Three different batches of pH sensors showed similar near super-Nernstian response which ranges from –71.6 mV/pH to –110 mV/pH as reproducible sensitivity in our fabrication process. These sensors demonstrated good reversibility, and similar response times to show the good reproducibility and repeatability in our fabrication process. Different volumes of fluid and step potential tests demonstrated good stability with three different batches of pH sensors. However, some potential deviations happened in the experiments. It  Figure 8 Potential responses in titration experiments. Figure 7 Large and small volume environment results. Proc. of SPIE Vol. 7269  726916-7 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms  may be due to the issues associated with the space charges, oxidation state, and film hydroxylation. Those phenomena maybe caused by the porous distribution, thickness, and surface properties of the IrOx thin film. With respect to the surface factors and different redox reactions occurred and related to changes of the pH charging potential, the fabrication quality control in the thickness and crystal structures of IrOx film is very important during the fabrication processes.  ACKNOWLEDGEMENT The authors would like to express their sincere appreciation to US Air Force Office of Scientific Research for their financial support. REFERENCES [1] H. Galster, pH measurements-fundamentals, methods, applications, instruments, VCH publishers, New York, 1991. [2] Yi Liu, Tianhoung Cui, “Ion-sensitive field-effect transistor based pH sensors using nano self- assembled polyelectrolyte/nanoparticle multilayer films,” Sensors and Actuators B, Vol. 123, pp. 148-152, Aug. 2006. [3] Jinghong Han, Dafu Cui, Yating Li, et al., “A gastroesophageal tract pH sensor based on the H- ISFET and the monitoring system for 24 h,” Sensors and Actuators B, Vol. 66, pp. 203-204, July 2000. [4] Otto S. Wolfbeis, “Fiber-optic chemical sensors and biosensors,” Anal. Chem., Vol. 76, pp. 3269- 3284, 2004. [5] Saying Dong, Ming Luo, Gangding Peng, and Wenhua Cheng, “Broad range pH sensor based on sol– gel entrapped indicators on fiber optic,” Sensors and Actuators B: Chemical, Vol. 129, pp. 94-98, Jan. 2008. [6] Gerald Gerlach, Margarita Guenther, et. al, “Chemical and pH sensors based on the swelling behavior of hydrogels,” Sensors and Actuators B, Vol. 111-112, pp. 555-561, Nov. 2005. [7] Agner Fog, Richard P. Buck, “Electronic semiconducting oxides as pH sensors,” Sensors and Actuators, Vol. 6, pp. 137-146, 1984. [8] Patrick J. Kinlen, John E. Heider, and David E. Hubbard, “A solid-state pH sensor based on a Nafion- coated iridium oxide indicator electrode and a polymer-based silver chloride reference electrode,” Sensors and Actuators B, Vol. 22, pp. 13-25, 1994. [9] Roy Biran, David C. Martin and Patrick A. Tresco, “Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays,” Experimental Neurology, Vol. 195, pp. 115-126, 2005. [10] Vadim S. Polikov, Patrick A. Tresco and William M. Reichert, “Response of brain tissue to chronically implanted neural electrodes,” Journal of Neuroscience Methods, Vol. 148: pp.1-18, 2005. [11] Jianqun Wang, Ying Cai, Thermpon Ativanichayaphong, Mu Chiao and J.-C. Chiao, “Fabrication techniques for RF transmission lines on polymer substrates,” Microelectronics, MEMS, and Nanotechnology Symposium, Microelectronics: Design, Technology, and Packaging Conference, Brisbane Australia, Dec. 11-14, 2005. [12] Wen-Ding Huang, Jianqun Wang, Thermpon Ativanichayaphong, Mu Chiao and J.C. Chiao, “Development of an IrOx Micro pH Sensor Array on Flexible Polymer Substrate,” SPIE Nanosensors and Microsensors for Bio-Systems Conference, San Diego, March 9-13, Vol. 6931, 693104, 2008. Proc. of SPIE Vol. 7269  726916-8 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms  [13] C. Jefferey Brinker, George W. Scherer, Sol-Gel Science: The physics and Chemistry of Sol-Gel Processing, pp.788-798, Academic Press, Boston, 1990. [14] K. Nishio, Y. Watanabe, T. Tsuchiya, “Preparation and properties of electrochromic iridium oxide thin film by sol-gel process,” Thin Solid Films, Vol. 350, pp. 96-100, 1999. [15] Akiyoshi Osaka, Toru Takatsuna, Yoshinari Miura, “Iridium oxide films via sol-gel processing,” Non-Crystalline Solids, Vol. 178, pp. 313-319, 1994. [16] A W J Cranny, J K Atkinson, "Thick film silver–silver chloride reference electrodes," Meas. Sci. Technol, pp.1557-1565, 1998. [17] Xin Q. Brown, Keiko Ookawa, and Joyce Y. Wong, "Evaluation of polydimethylsiloxane scaffolds with physiologically relevant elastic moduli: interplay of substrate mechanics and surface chemistry effects on vascular smooth muscle cell response," Biomaterials, Vol. 26, pp. 3123-3129, 2005. [18] M. Pourbaix, "Atlas of electrochemical equilibria in aqueous solutions," National Association of Corrosion Engineers, pp. 374-377, 1974. [19] Sheng Yao, Min Wang, and Marc Madou, "A pH electrode based on melt-oxidized iridium oxide," Journal of the elecvtrochemical society, Vol. 148, pp. 29-36, 2001. [20] Erno Pungor, "The theory of ion-selective electrodes," The Japan society for analytical chemistry, Vol. 14, pp. 249-256, 1998. [21] Haley R. Clark, Timothy A. Barbari, "Modeling the response time of an in vivo glucose affinity sensor," Biotechnol. Prog., Vol. 15, pp. 259-266, 1999. [22] Santi Chrisanti, "A pH electrode based on melt-oxidized iridium oxide," Master Degree Thesis, Ohio State University, pp. 25-26, 2003. [23] W. Olthuis, M. A. M. Robben, P. Bergveld, M. Bos and, W. E. van der Linden, "pH sensor properties of electrochemically grown iridium oxide," Sensor and Actuators B, Vol. 2, pp. 247-256, 1990. [24] Reagecon Technical Report, "The Theory of pH Measurement," pp.8-9, http://www.reagecon.com/TechPapers/phfaqv4.pdf.           Proc. of SPIE Vol. 7269  726916-9 Downloaded from SPIE Digital Library on 31 Oct 2011 to Terms of Use:  http://spiedl.org/terms


Citation Scheme:


Usage Statistics

Country Views Downloads
China 7 7
City Views Downloads
Nanjing 4 0
Beijing 3 7

{[{ mDataHeader[type] }]} {[{ month[type] }]} {[{ tData[type] }]}


Share to:


Related Items