- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Undergraduate Research /
- Beam bunch length measurement for the ARIEL e-LINAC
Open Collections
UBC Undergraduate Research
Beam bunch length measurement for the ARIEL e-LINAC Vrielink, Alysson
Abstract
The following document presents measurements conducted to determine and
manipulate the beam bunch length in an electron linear accelerator at TRIUMF's
new ARIEL facility. This method uses a radiofrequency resonant cavity that operates
in a mode with transverse electromagnetic fields on axis. These fields deflect
electrons by a magnitude dependent on the phase of the radiofrequency fields at
the arrival time of the electron. Therefore, it is possible to convert the spread of
electrons after the deflection
to a profile of the beam in the time domain before
it reached the deflecting
cavity.
This relationship between bunch length and vertical spread after the deflecting
cavity requires that certain properties of the cavity be measured. In particular, the
effective shunt impedance must be known, a parameter that gives the relationship
between input power and effective cavity voltage. To obtain this measurement,
we look at the effect of the deflecting
cavity on the beam and compare this with
results obtained from simulations using a 3D beam dynamics program, General
Particle Tracer. Preliminary results suggest the effective shunt impedance of the
deflecting
cavity is 0.81MΩ,
however this should be confirmed with further data
collection.
In addition to beam bunch length measurements, this project characterized the
bunching cavity, a radio-frequency resonant cavity designed to focus the beam in
the time domain. Using the bunching cavity in conjunction with the deflector
cavity, we were able to measure the nominal bunching power for optimal focusing
at the deflecting
cavity to be 48.5W. When compared with computer simulations,
the shunt impedance of the buncher was calculated to be 0.326MΩ.
This shunt
impedance can be used to determine the input power required for optimal temporal
focusing of the beam at any point along the beamline. This is important as
a focused bunch is highly desirable for downstream users.
As these results are only a first estimate, it would be useful to do further
data collection to confirm these values and obtain error bounds. In addition,
the computer simulations could be improved by using more recent estimates of
the input beam characteristics (standard deviation of the bunch in the x, y and
z directions, beam energy, etc...). Having obtained the most accurate results
possible for the shunt impedance of the deflecting
cavity, a final recommendation
would be to develop a program that can rapidly analyze images of the beam after
the deflector
and output the beam bunch length.
Item Metadata
| Title |
Beam bunch length measurement for the ARIEL e-LINAC
|
| Creator | |
| Date Issued |
2013-01-16
|
| Description |
The following document presents measurements conducted to determine and
manipulate the beam bunch length in an electron linear accelerator at TRIUMF's
new ARIEL facility. This method uses a radiofrequency resonant cavity that operates
in a mode with transverse electromagnetic fields on axis. These fields deflect
electrons by a magnitude dependent on the phase of the radiofrequency fields at
the arrival time of the electron. Therefore, it is possible to convert the spread of
electrons after the deflection
to a profile of the beam in the time domain before
it reached the deflecting
cavity.
This relationship between bunch length and vertical spread after the deflecting
cavity requires that certain properties of the cavity be measured. In particular, the
effective shunt impedance must be known, a parameter that gives the relationship
between input power and effective cavity voltage. To obtain this measurement,
we look at the effect of the deflecting
cavity on the beam and compare this with
results obtained from simulations using a 3D beam dynamics program, General
Particle Tracer. Preliminary results suggest the effective shunt impedance of the
deflecting
cavity is 0.81MΩ,
however this should be confirmed with further data
collection.
In addition to beam bunch length measurements, this project characterized the
bunching cavity, a radio-frequency resonant cavity designed to focus the beam in
the time domain. Using the bunching cavity in conjunction with the deflector
cavity, we were able to measure the nominal bunching power for optimal focusing
at the deflecting
cavity to be 48.5W. When compared with computer simulations,
the shunt impedance of the buncher was calculated to be 0.326MΩ.
This shunt
impedance can be used to determine the input power required for optimal temporal
focusing of the beam at any point along the beamline. This is important as
a focused bunch is highly desirable for downstream users.
As these results are only a first estimate, it would be useful to do further
data collection to confirm these values and obtain error bounds. In addition,
the computer simulations could be improved by using more recent estimates of
the input beam characteristics (standard deviation of the bunch in the x, y and
z directions, beam energy, etc...). Having obtained the most accurate results
possible for the shunt impedance of the deflecting
cavity, a final recommendation
would be to develop a program that can rapidly analyze images of the beam after
the deflector
and output the beam bunch length.
|
| Genre | |
| Type | |
| Language |
eng
|
| Series | |
| Date Available |
2013-11-29
|
| Provider |
Vancouver : University of British Columbia Library
|
| Rights |
Attribution-NonCommercial-NoDerivatives 4.0 International
|
| DOI |
10.14288/1.0074501
|
| URI | |
| Affiliation | |
| Campus | |
| Peer Review Status |
Unreviewed
|
| Scholarly Level |
Undergraduate
|
| Rights URI | |
| Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International