- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Faculty Research and Publications /
- Diagnosing Sport-Related Flow Limitations in the Iliac...
Open Collections
UBC Faculty Research and Publications
Diagnosing Sport-Related Flow Limitations in the Iliac Arteries Using Near-Infrared Spectroscopy van Hooff, Martijn; Arnold, Jem I.; Meijer, Eduard; Schreuder, Paul; Regis, Marta; Xu, Lin; Scheltinga, Marc; Savelberg, Hans; Schep, Goof
Abstract
Background: A flow limitation in the iliac arteries (FLIA) in endurance athletes is notoriously difficult to diagnose with the currently available diagnostic tools. At present, a commonly used diagnostic measure is a decrease in ankle brachial index with flex hips (ABIFlexed) following a maximal effort exercise test. Near-infrared spectroscopy (NIRS) is a non-invasive technique that measures skeletal muscle oxygenation as reflected by the balance of O2 delivery from microvascular blood flow and O2 uptake by metabolic activity. Therefore, NIRS potentially serves as a novel technique for diagnosing FLIA. The purpose of this study is to compare the diagnostic accuracy of NIRS-derived absolute, amplitude, and kinetic variables in legs during and after a maximal exercise test with ABIFlexed. Methods: ABIFlexed and NIRS were studied in 33 healthy subjects and 201 patients with FLIA diagnosed with echo-Doppler. Results: After maximal exercise, NIRS kinetic variables, such as the half value time and mean response time, resulted in a range of 0.921 to 0.939 AUC for the diagnosis of FLIA when combined with ABIFlexed. Conversely, ABIFlexed measurements alone conferred significantly worse test characteristics (AUC 0.717, p < 0.001). Conclusions: NIRS may serve as a diagnostic adjunct in patients with possible FLIA.
Item Metadata
| Title |
Diagnosing Sport-Related Flow Limitations in the Iliac Arteries Using Near-Infrared Spectroscopy
|
| Creator | |
| Publisher |
Multidisciplinary Digital Publishing Institute
|
| Date Issued |
2022-12-16
|
| Description |
Background: A flow limitation in the iliac arteries (FLIA) in endurance athletes is notoriously difficult to diagnose with the currently available diagnostic tools. At present, a commonly used diagnostic measure is a decrease in ankle brachial index with flex hips (ABIFlexed) following a maximal effort exercise test. Near-infrared spectroscopy (NIRS) is a non-invasive technique that measures skeletal muscle oxygenation as reflected by the balance of O2 delivery from microvascular blood flow and O2 uptake by metabolic activity. Therefore, NIRS potentially serves as a novel technique for diagnosing FLIA. The purpose of this study is to compare the diagnostic accuracy of NIRS-derived absolute, amplitude, and kinetic variables in legs during and after a maximal exercise test with ABIFlexed. Methods: ABIFlexed and NIRS were studied in 33 healthy subjects and 201 patients with FLIA diagnosed with echo-Doppler. Results: After maximal exercise, NIRS kinetic variables, such as the half value time and mean response time, resulted in a range of 0.921 to 0.939 AUC for the diagnosis of FLIA when combined with ABIFlexed. Conversely, ABIFlexed measurements alone conferred significantly worse test characteristics (AUC 0.717, p < 0.001). Conclusions: NIRS may serve as a diagnostic adjunct in patients with possible FLIA.
|
| Subject | |
| Genre | |
| Type | |
| Language |
eng
|
| Date Available |
2025-06-12
|
| Provider |
Vancouver : University of British Columbia Library
|
| Rights |
CC BY 4.0
|
| DOI |
10.14288/1.0449096
|
| URI | |
| Affiliation | |
| Citation |
Journal of Clinical Medicine 11 (24): 7462 (2022)
|
| Publisher DOI |
10.3390/jcm11247462
|
| Peer Review Status |
Reviewed
|
| Scholarly Level |
Faculty; Researcher
|
| Rights URI | |
| Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
CC BY 4.0