- Library Home /
- Search Collections /
- Open Collections /
- Browse Collections /
- UBC Faculty Research and Publications /
- Particle Image Velocimetry Measurements of the Flow-Diverting...
Open Collections
UBC Faculty Research and Publications
Particle Image Velocimetry Measurements of the Flow-Diverting Effects of a New Generation of the eCLIPs Implant for the Treatment of Intracranial Bifurcation Aneurysms G. Yazdi, Sina; Mercier, Daniel; Bernard, Renee; Tynan, Adam; Ricci, Donald R.
Abstract
Flow diverters (FDs) for the endovascular treatment of intracranial aneurysms are effective for sidewall aneurysms, but their use at a bifurcation is problematic because FDs only partially cover the aneurysm neck and impede flow into a daughter branch; they are thus not employed routinely in this anatomy. eCLIPs was developed as a non-tubular implant to completely cover the neck of an aneurysm and serve as a coil retention device necessary for the adequate treatment of wide-neck bifurcation aneurysms. eCLIPs has shown some flow diversion effects in bifurcation anatomy but not equal to those exhibited by clinically accepted flow diverters in sidewall anatomy. A new generation of eCLIPs implant, the eCLIPs bifurcation flow diverter (eBFD), with higher metal coverage, was developed to achieve a similar flow diversion as a Pipeline Embolization Device (PED), a prototypical FD. Particle image velocimetry was used to capture the fluid dynamics and velocity reduction within silicone aneurysm replicas. A circulatory mimicking loop was developed to circulate the flow through the silicone models. All generations of eCLIPs implants had some flow-diverting effect, with increasing metal coverage density of the implant proportionately increasing the flow diversion effect. The eBFD, with a metal density of 35%, showed greater flow diversion than PED, with 30% metal density, for bifurcation anatomy. The eBFD showed similar reduction of flow in a bifurcation anatomy to PED in a sidewall, both sufficient to permit early thrombosis of the aneurysm. Thus, the eBFD can potentially provide sufficient flow diversion for the treatment of bifurcation aneurysms to avoid adjunctive coiling.
Item Metadata
| Title |
Particle Image Velocimetry Measurements of the Flow-Diverting Effects of a New Generation of the eCLIPs Implant for the Treatment of Intracranial Bifurcation Aneurysms
|
| Creator | |
| Publisher |
Multidisciplinary Digital Publishing Institute
|
| Date Issued |
2020-12-03
|
| Description |
Flow diverters (FDs) for the endovascular treatment of intracranial aneurysms are effective for sidewall aneurysms, but their use at a bifurcation is problematic because FDs only partially cover the aneurysm neck and impede flow into a daughter branch; they are thus not employed routinely in this anatomy. eCLIPs was developed as a non-tubular implant to completely cover the neck of an aneurysm and serve as a coil retention device necessary for the adequate treatment of wide-neck bifurcation aneurysms. eCLIPs has shown some flow diversion effects in bifurcation anatomy but not equal to those exhibited by clinically accepted flow diverters in sidewall anatomy. A new generation of eCLIPs implant, the eCLIPs bifurcation flow diverter (eBFD), with higher metal coverage, was developed to achieve a similar flow diversion as a Pipeline Embolization Device (PED), a prototypical FD. Particle image velocimetry was used to capture the fluid dynamics and velocity reduction within silicone aneurysm replicas. A circulatory mimicking loop was developed to circulate the flow through the silicone models. All generations of eCLIPs implants had some flow-diverting effect, with increasing metal coverage density of the implant proportionately increasing the flow diversion effect. The eBFD, with a metal density of 35%, showed greater flow diversion than PED, with 30% metal density, for bifurcation anatomy. The eBFD showed similar reduction of flow in a bifurcation anatomy to PED in a sidewall, both sufficient to permit early thrombosis of the aneurysm. Thus, the eBFD can potentially provide sufficient flow diversion for the treatment of bifurcation aneurysms to avoid adjunctive coiling.
|
| Subject | |
| Genre | |
| Type | |
| Language |
eng
|
| Date Available |
2020-12-10
|
| Provider |
Vancouver : University of British Columbia Library
|
| Rights |
CC BY 4.0
|
| DOI |
10.14288/1.0395220
|
| URI | |
| Affiliation | |
| Citation |
Applied Sciences 10 (23): 8639 (2020)
|
| Publisher DOI |
10.3390/app10238639
|
| Peer Review Status |
Reviewed
|
| Scholarly Level |
Faculty
|
| Rights URI | |
| Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
CC BY 4.0